The Veris Industries H622-10 Hawkeye is a high-performance analog current transducer designed for precision monitoring in building automation and motor control applications. This split-core current sensor converts 0 to 10 Amps AC into a proportional 0-5VDC output signal, making it an ideal interface for DDC controllers and data acquisition systems. Engineered for rugged field use, the solid-state design features a 1.2" x 1.1" sensing cavity and is induced powered from the monitored conductor, eliminating the need for an external power supply and simplifying your wiring layout. Technical specifications include an insulation class of 600VAC RMS (UL) and a 100% solid-state architecture that ensures long-term reliability in environments ranging from -15 to 60°C.

For contractors, the H622-10 current sensor excels in retrofit scenarios. The self-gripping split-core housing allows for fast installation on existing conductors without disconnecting lines, saving significant labor time on the job site. With factory-calibrated ranges and a jumper-free configuration, you avoid common field-scaling errors. This sensor is frequently utilized for HVAC current monitoring, load trending, and verified proof-of-flow for fan and pump motors. Its high-accuracy current monitoring capability (±2% full scale) ensures precise data for energy management and equipment diagnostics.

Key Benefits for Technicians
  • Simplifies installation with a self-powered design that removes the requirement for local power wiring.
  • Accelerates retrofits using a self-gripping, split-core mechanism that snaps onto conductors without breaking the circuit.
  • Reduces troubleshooting via a factory-calibrated setup, ensuring immediate 0-5VDC signal accuracy across the 10A range.
  • Optimizes panel space with a compact 2.9" x 2.5" footprint and a removable mounting bracket for versatile positioning.
  • Ensures durability through a 100% solid-state construction with no moving parts to wear out or fail.
Common Questions & Answers

How do I scale the controller for the 0 to 10A range?
Configure your building automation system to interpret 0VDC as 0 Amps and 5VDC as 10 Amps. This linear analog output transducer provides a direct proportional relationship for easy software scaling.

Can I use this sensor for loads smaller than 1A?
Yes. To monitor low-amperage loads, wrap the conductor multiple times through the sensing window. Divide the controller's reading by the number of turns to get the actual amperage.

What is the maximum wire gauge for the terminal blocks?
The integrated terminal blocks accept wire sizes ranging from 24 to 14 AWG, accommodating standard control wiring and ensuring a secure connection with a nominal torque of 4 in-lb.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$48.44
Veris Industries H622-10 Sensor
$48.44

Veris Industries H622-10 Sensor

The Veris Industries H622-10 Hawkeye is a high-performance analog current transducer designed for precision monitoring in building automation and motor control applications. This split-core current sensor converts 0 to 10 Amps AC into a proportional 0-5VDC output signal, making it an ideal interface for DDC controllers and data acquisition systems. Engineered for rugged field use, the solid-state design features a 1.2" x 1.1" sensing cavity and is induced powered from the monitored conductor, eliminating the need for an external power supply and simplifying your wiring layout. Technical specifications include an insulation class of 600VAC RMS (UL) and a 100% solid-state architecture that ensures long-term reliability in environments ranging from -15 to 60°C.

For contractors, the H622-10 current sensor excels in retrofit scenarios. The self-gripping split-core housing allows for fast installation on existing conductors without disconnecting lines, saving significant labor time on the job site. With factory-calibrated ranges and a jumper-free configuration, you avoid common field-scaling errors. This sensor is frequently utilized for HVAC current monitoring, load trending, and verified proof-of-flow for fan and pump motors. Its high-accuracy current monitoring capability (±2% full scale) ensures precise data for energy management and equipment diagnostics.

Key Benefits for Technicians
  • Simplifies installation with a self-powered design that removes the requirement for local power wiring.
  • Accelerates retrofits using a self-gripping, split-core mechanism that snaps onto conductors without breaking the circuit.
  • Reduces troubleshooting via a factory-calibrated setup, ensuring immediate 0-5VDC signal accuracy across the 10A range.
  • Optimizes panel space with a compact 2.9" x 2.5" footprint and a removable mounting bracket for versatile positioning.
  • Ensures durability through a 100% solid-state construction with no moving parts to wear out or fail.
Common Questions & Answers

How do I scale the controller for the 0 to 10A range?
Configure your building automation system to interpret 0VDC as 0 Amps and 5VDC as 10 Amps. This linear analog output transducer provides a direct proportional relationship for easy software scaling.

Can I use this sensor for loads smaller than 1A?
Yes. To monitor low-amperage loads, wrap the conductor multiple times through the sensing window. Divide the controller's reading by the number of turns to get the actual amperage.

What is the maximum wire gauge for the terminal blocks?
The integrated terminal blocks accept wire sizes ranging from 24 to 14 AWG, accommodating standard control wiring and ensuring a secure connection with a nominal torque of 4 in-lb.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Veris Industries H622-10 Hawkeye is a high-performance analog current transducer designed for precision monitoring in building automation and motor control applications. This split-core current sensor converts 0 to 10 Amps AC into a proportional 0-5VDC output signal, making it an ideal interface for DDC controllers and data acquisition systems. Engineered for rugged field use, the solid-state design features a 1.2" x 1.1" sensing cavity and is induced powered from the monitored conductor, eliminating the need for an external power supply and simplifying your wiring layout. Technical specifications include an insulation class of 600VAC RMS (UL) and a 100% solid-state architecture that ensures long-term reliability in environments ranging from -15 to 60°C.

For contractors, the H622-10 current sensor excels in retrofit scenarios. The self-gripping split-core housing allows for fast installation on existing conductors without disconnecting lines, saving significant labor time on the job site. With factory-calibrated ranges and a jumper-free configuration, you avoid common field-scaling errors. This sensor is frequently utilized for HVAC current monitoring, load trending, and verified proof-of-flow for fan and pump motors. Its high-accuracy current monitoring capability (±2% full scale) ensures precise data for energy management and equipment diagnostics.

Key Benefits for Technicians
  • Simplifies installation with a self-powered design that removes the requirement for local power wiring.
  • Accelerates retrofits using a self-gripping, split-core mechanism that snaps onto conductors without breaking the circuit.
  • Reduces troubleshooting via a factory-calibrated setup, ensuring immediate 0-5VDC signal accuracy across the 10A range.
  • Optimizes panel space with a compact 2.9" x 2.5" footprint and a removable mounting bracket for versatile positioning.
  • Ensures durability through a 100% solid-state construction with no moving parts to wear out or fail.
Common Questions & Answers

How do I scale the controller for the 0 to 10A range?
Configure your building automation system to interpret 0VDC as 0 Amps and 5VDC as 10 Amps. This linear analog output transducer provides a direct proportional relationship for easy software scaling.

Can I use this sensor for loads smaller than 1A?
Yes. To monitor low-amperage loads, wrap the conductor multiple times through the sensing window. Divide the controller's reading by the number of turns to get the actual amperage.

What is the maximum wire gauge for the terminal blocks?
The integrated terminal blocks accept wire sizes ranging from 24 to 14 AWG, accommodating standard control wiring and ensuring a secure connection with a nominal torque of 4 in-lb.