The Veris Industries TW2LAXA Sensor is a professional-grade wall mount temperature transmitter designed for precise environmental monitoring in commercial BAS and HVAC applications. Engineered for seamless integration with controllers accepting 4-20mA, 0-5Vdc, or 0-10Vdc analog outputs, this unit features a robust segmented LCD display with three tactile buttons for local monitoring and field adjustments. Operating within a 32-122°F (0-50°C) range, the sensor utilizes a solid-state integrated circuit to deliver typical accuracy of ±0.4°F, ensuring reliable data for critical climate control. The TW2LAXA includes a 0-10V setpoint and a momentary-to-ground override button, allowing for immediate setpoint manipulation and occupancy signaling. Its high-impact ABS plastic housing supports surface mounting on standard single-gang J-boxes, making it a versatile choice for building automation systems. No field calibration is required, and the DIP switch selectable outputs streamline inventory requirements for contractors managing diverse site specifications.

Key Benefits:
  • Selectable Analog Outputs: Configurable for 4-20 mA, 0-5 V, or 0-10 V to match various BAS controller requirements.
  • Enhanced Local Interface: High-visibility 3-button LCD provides real-time temperature data and simplified setpoint adjustment.
  • Field Flexibility: Features DIP switch selectable temperature ranges and setpoint types (temperature or fan speed) for on-site adaptability.
  • Accuracy and Reliability: Solid-state sensing technology provides 0.1°F resolution without the need for periodic calibration.
  • Contractor-Friendly Install: Large screw terminals accommodate 18-24 AWG wiring, and the snap-on cover with a security screw ensures a clean, tamper-resistant finish.
Common Questions:

How do I change the output signal from voltage to current?
The output type is selected via internal DIP switches on the circuit board; ensure power is disconnected before adjusting switches between 4-20mA and voltage modes.

Can the setpoint be used to control fan speed?
Yes, the 0-10V setpoint output is DIP switch selectable to function as either a temperature setpoint or a fan speed controller (Off, Low, Med, High).

Which wiring gauge is recommended for this sensor?
Standard 18 to 24 AWG shielded twisted-pair cable is recommended for best performance and ease of installation in terminal blocks.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$94.36
Veris Industries TW2LAXA Sensor
$94.36

Veris Industries TW2LAXA Sensor

The Veris Industries TW2LAXA Sensor is a professional-grade wall mount temperature transmitter designed for precise environmental monitoring in commercial BAS and HVAC applications. Engineered for seamless integration with controllers accepting 4-20mA, 0-5Vdc, or 0-10Vdc analog outputs, this unit features a robust segmented LCD display with three tactile buttons for local monitoring and field adjustments. Operating within a 32-122°F (0-50°C) range, the sensor utilizes a solid-state integrated circuit to deliver typical accuracy of ±0.4°F, ensuring reliable data for critical climate control. The TW2LAXA includes a 0-10V setpoint and a momentary-to-ground override button, allowing for immediate setpoint manipulation and occupancy signaling. Its high-impact ABS plastic housing supports surface mounting on standard single-gang J-boxes, making it a versatile choice for building automation systems. No field calibration is required, and the DIP switch selectable outputs streamline inventory requirements for contractors managing diverse site specifications.

Key Benefits:
  • Selectable Analog Outputs: Configurable for 4-20 mA, 0-5 V, or 0-10 V to match various BAS controller requirements.
  • Enhanced Local Interface: High-visibility 3-button LCD provides real-time temperature data and simplified setpoint adjustment.
  • Field Flexibility: Features DIP switch selectable temperature ranges and setpoint types (temperature or fan speed) for on-site adaptability.
  • Accuracy and Reliability: Solid-state sensing technology provides 0.1°F resolution without the need for periodic calibration.
  • Contractor-Friendly Install: Large screw terminals accommodate 18-24 AWG wiring, and the snap-on cover with a security screw ensures a clean, tamper-resistant finish.
Common Questions:

How do I change the output signal from voltage to current?
The output type is selected via internal DIP switches on the circuit board; ensure power is disconnected before adjusting switches between 4-20mA and voltage modes.

Can the setpoint be used to control fan speed?
Yes, the 0-10V setpoint output is DIP switch selectable to function as either a temperature setpoint or a fan speed controller (Off, Low, Med, High).

Which wiring gauge is recommended for this sensor?
Standard 18 to 24 AWG shielded twisted-pair cable is recommended for best performance and ease of installation in terminal blocks.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Veris Industries TW2LAXA Sensor is a professional-grade wall mount temperature transmitter designed for precise environmental monitoring in commercial BAS and HVAC applications. Engineered for seamless integration with controllers accepting 4-20mA, 0-5Vdc, or 0-10Vdc analog outputs, this unit features a robust segmented LCD display with three tactile buttons for local monitoring and field adjustments. Operating within a 32-122°F (0-50°C) range, the sensor utilizes a solid-state integrated circuit to deliver typical accuracy of ±0.4°F, ensuring reliable data for critical climate control. The TW2LAXA includes a 0-10V setpoint and a momentary-to-ground override button, allowing for immediate setpoint manipulation and occupancy signaling. Its high-impact ABS plastic housing supports surface mounting on standard single-gang J-boxes, making it a versatile choice for building automation systems. No field calibration is required, and the DIP switch selectable outputs streamline inventory requirements for contractors managing diverse site specifications.

Key Benefits:
  • Selectable Analog Outputs: Configurable for 4-20 mA, 0-5 V, or 0-10 V to match various BAS controller requirements.
  • Enhanced Local Interface: High-visibility 3-button LCD provides real-time temperature data and simplified setpoint adjustment.
  • Field Flexibility: Features DIP switch selectable temperature ranges and setpoint types (temperature or fan speed) for on-site adaptability.
  • Accuracy and Reliability: Solid-state sensing technology provides 0.1°F resolution without the need for periodic calibration.
  • Contractor-Friendly Install: Large screw terminals accommodate 18-24 AWG wiring, and the snap-on cover with a security screw ensures a clean, tamper-resistant finish.
Common Questions:

How do I change the output signal from voltage to current?
The output type is selected via internal DIP switches on the circuit board; ensure power is disconnected before adjusting switches between 4-20mA and voltage modes.

Can the setpoint be used to control fan speed?
Yes, the 0-10V setpoint output is DIP switch selectable to function as either a temperature setpoint or a fan speed controller (Off, Low, Med, High).

Which wiring gauge is recommended for this sensor?
Standard 18 to 24 AWG shielded twisted-pair cable is recommended for best performance and ease of installation in terminal blocks.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.