Veris Industries EP2100S2 Transducer
HomeStore

Veris Industries EP2100S2 Transducer

Veris Industries EP2100S2 Transducer

The Veris Industries EP2100S2 is a high-performance electropneumatic transducer designed for precise pneumatic control in commercial HVACR environments. Utilizing advanced microcontrolled poppet valve technology, this unit converts electronic signals into proportional pneumatic outputs—either 3-15 psi or 0-20 psig—while consuming zero air when at a steady state. This eliminates internal air losses common in older flapper-nozzle designs, making it an essential upgrade for building automation systems. With field-selectable 4-20 mA, 0-5 V, or 0-10 VDC control inputs, the EP2 series offers maximum flexibility for different controller types, from legacy analog systems to modern DDC panels. The EP2100S2 includes a 3-1/2 digit LCD for real-time pressure monitoring and a durable EP cover plate for added protection. For commissioning and troubleshooting, the manual override with set and hold allows technicians to verify damper or actuator operation even in systems with minor leaks, ensuring optimal HVAC performance and easier system balancing.

Key Benefits for Technicians:
  • Efficient Poppet Valve Technology: Minimizes compressor run-time by eliminating bleed air during steady-state operation.
  • Selectable Control Inputs: Jumper-selectable input and output ranges reduce the need for carrying multiple SKUs on the service truck.
  • Diagnostic On-Board Display: Integrated LCD display and LED indicators provide instant visual feedback on system pressure and power status.
  • Manual Override Feature: Simplifies the commissioning process by allowing manual pressure adjustment to test pneumatic actuators.
  • SnapTrack Mounting: Fast and secure installation directly into control cabinets using standard SnapTrack hardware.
Common Questions:

Can I use this device with oxygen service?
No, this transducer is rated for clean, dry air or inert gases only. Using it with oxygen service is strictly prohibited for safety reasons.

What happens if the power to the unit fails?
The EP2100S2 is a non-failsafe model. If your application requires the branch pressure to vent upon power loss, you should specify an EP2101S2 or similar model with a fail-safe vent.

Does it require a specific tubing length for stability?
For best performance and to prevent hunting, a minimum of 15 feet of 1/8” I.D. poly tubing is recommended between the transducer and the controlled device.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$71.38

Original: $203.93

-65%
Veris Industries EP2100S2 Transducer

$203.93

$71.38

Veris Industries EP2100S2 Transducer

The Veris Industries EP2100S2 is a high-performance electropneumatic transducer designed for precise pneumatic control in commercial HVACR environments. Utilizing advanced microcontrolled poppet valve technology, this unit converts electronic signals into proportional pneumatic outputs—either 3-15 psi or 0-20 psig—while consuming zero air when at a steady state. This eliminates internal air losses common in older flapper-nozzle designs, making it an essential upgrade for building automation systems. With field-selectable 4-20 mA, 0-5 V, or 0-10 VDC control inputs, the EP2 series offers maximum flexibility for different controller types, from legacy analog systems to modern DDC panels. The EP2100S2 includes a 3-1/2 digit LCD for real-time pressure monitoring and a durable EP cover plate for added protection. For commissioning and troubleshooting, the manual override with set and hold allows technicians to verify damper or actuator operation even in systems with minor leaks, ensuring optimal HVAC performance and easier system balancing.

Key Benefits for Technicians:
  • Efficient Poppet Valve Technology: Minimizes compressor run-time by eliminating bleed air during steady-state operation.
  • Selectable Control Inputs: Jumper-selectable input and output ranges reduce the need for carrying multiple SKUs on the service truck.
  • Diagnostic On-Board Display: Integrated LCD display and LED indicators provide instant visual feedback on system pressure and power status.
  • Manual Override Feature: Simplifies the commissioning process by allowing manual pressure adjustment to test pneumatic actuators.
  • SnapTrack Mounting: Fast and secure installation directly into control cabinets using standard SnapTrack hardware.
Common Questions:

Can I use this device with oxygen service?
No, this transducer is rated for clean, dry air or inert gases only. Using it with oxygen service is strictly prohibited for safety reasons.

What happens if the power to the unit fails?
The EP2100S2 is a non-failsafe model. If your application requires the branch pressure to vent upon power loss, you should specify an EP2101S2 or similar model with a fail-safe vent.

Does it require a specific tubing length for stability?
For best performance and to prevent hunting, a minimum of 15 feet of 1/8” I.D. poly tubing is recommended between the transducer and the controlled device.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Veris Industries EP2100S2 is a high-performance electropneumatic transducer designed for precise pneumatic control in commercial HVACR environments. Utilizing advanced microcontrolled poppet valve technology, this unit converts electronic signals into proportional pneumatic outputs—either 3-15 psi or 0-20 psig—while consuming zero air when at a steady state. This eliminates internal air losses common in older flapper-nozzle designs, making it an essential upgrade for building automation systems. With field-selectable 4-20 mA, 0-5 V, or 0-10 VDC control inputs, the EP2 series offers maximum flexibility for different controller types, from legacy analog systems to modern DDC panels. The EP2100S2 includes a 3-1/2 digit LCD for real-time pressure monitoring and a durable EP cover plate for added protection. For commissioning and troubleshooting, the manual override with set and hold allows technicians to verify damper or actuator operation even in systems with minor leaks, ensuring optimal HVAC performance and easier system balancing.

Key Benefits for Technicians:
  • Efficient Poppet Valve Technology: Minimizes compressor run-time by eliminating bleed air during steady-state operation.
  • Selectable Control Inputs: Jumper-selectable input and output ranges reduce the need for carrying multiple SKUs on the service truck.
  • Diagnostic On-Board Display: Integrated LCD display and LED indicators provide instant visual feedback on system pressure and power status.
  • Manual Override Feature: Simplifies the commissioning process by allowing manual pressure adjustment to test pneumatic actuators.
  • SnapTrack Mounting: Fast and secure installation directly into control cabinets using standard SnapTrack hardware.
Common Questions:

Can I use this device with oxygen service?
No, this transducer is rated for clean, dry air or inert gases only. Using it with oxygen service is strictly prohibited for safety reasons.

What happens if the power to the unit fails?
The EP2100S2 is a non-failsafe model. If your application requires the branch pressure to vent upon power loss, you should specify an EP2101S2 or similar model with a fail-safe vent.

Does it require a specific tubing length for stability?
For best performance and to prevent hunting, a minimum of 15 feet of 1/8” I.D. poly tubing is recommended between the transducer and the controlled device.