KMC Controls CCE-1001 Switch
The KMC Controls CCE-1001 is a commercial-grade Pneumatic-Electric (P/E) Switch designed for high-reliability HVAC control systems. This SPDT relay switch features a 2 PSI fixed differential, providing precise electrical activation in response to pneumatic pressure changes. Engineered for versatility, the CCE-1001 is a primary choice for starting fan coil units, managing exhaust fans, and industrial electric duct heater control. The unit is housed in a rugged case with a cover to protect the internal switching mechanism from debris and physical damage, ensuring consistent performance in demanding mechanical rooms. Wiring integration is streamlined via two 1/2-inch conduit openings, accommodating standard field installations. As a UL Listed and CSA approved component, it meets rigorous safety standards for 10-amp (125 VAC) or 5-amp (250 VAC) electrical loads. HVAC technicians rely on this KMC P/E switch for its stable switching action and its ability to maintain static pressure setpoints in air handlers and cooling towers without frequent recalibration.
Key Benefits- Precise Pressure Response: The 2# Fixed Differential ensures reliable switching without the hunting issues common in low-tolerance sensors.
- Robust SPDT Configuration: Allows for flexible Single-Pole Double-Throw wiring to manage multiple circuits or alarm states.
- Industrial Durability: Metal case and cover shield the switch mechanism, making it ideal for high-vibration fan coil unit environments.
- Standardized Installation: Dual conduit openings and 3/16" nipples for 1/4" O.D. tubing simplify HVAC replacement tasks.
- Regulatory Compliance: Fully UL and CSA listed, ensuring the part meets building code requirements for commercial electrical relays.
What are the electrical load ratings for the CCE-1001?
The KMC CCE-1001 is rated for 10 amps at 125 VAC and 5 amps at 250 VAC. Always verify your current draw before integrating into electric heater circuits.
Can this switch be used in cooling tower applications?
Yes, this pneumatic-electric switch is commonly utilized for cooling tower and compressor control where a fixed 2 PSI differential is required for operational stability.
Does it require filtered air for operation?
Like all pneumatic controls, the CCE-1001 requires clean, dry, oil-free control air to prevent internal switch failure and maintain accuracy over the life of the unit.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
KMC Controls CCE-1001 Switch
The KMC Controls CCE-1001 is a commercial-grade Pneumatic-Electric (P/E) Switch designed for high-reliability HVAC control systems. This SPDT relay switch features a 2 PSI fixed differential, providing precise electrical activation in response to pneumatic pressure changes. Engineered for versatility, the CCE-1001 is a primary choice for starting fan coil units, managing exhaust fans, and industrial electric duct heater control. The unit is housed in a rugged case with a cover to protect the internal switching mechanism from debris and physical damage, ensuring consistent performance in demanding mechanical rooms. Wiring integration is streamlined via two 1/2-inch conduit openings, accommodating standard field installations. As a UL Listed and CSA approved component, it meets rigorous safety standards for 10-amp (125 VAC) or 5-amp (250 VAC) electrical loads. HVAC technicians rely on this KMC P/E switch for its stable switching action and its ability to maintain static pressure setpoints in air handlers and cooling towers without frequent recalibration.
Key Benefits- Precise Pressure Response: The 2# Fixed Differential ensures reliable switching without the hunting issues common in low-tolerance sensors.
- Robust SPDT Configuration: Allows for flexible Single-Pole Double-Throw wiring to manage multiple circuits or alarm states.
- Industrial Durability: Metal case and cover shield the switch mechanism, making it ideal for high-vibration fan coil unit environments.
- Standardized Installation: Dual conduit openings and 3/16" nipples for 1/4" O.D. tubing simplify HVAC replacement tasks.
- Regulatory Compliance: Fully UL and CSA listed, ensuring the part meets building code requirements for commercial electrical relays.
What are the electrical load ratings for the CCE-1001?
The KMC CCE-1001 is rated for 10 amps at 125 VAC and 5 amps at 250 VAC. Always verify your current draw before integrating into electric heater circuits.
Can this switch be used in cooling tower applications?
Yes, this pneumatic-electric switch is commonly utilized for cooling tower and compressor control where a fixed 2 PSI differential is required for operational stability.
Does it require filtered air for operation?
Like all pneumatic controls, the CCE-1001 requires clean, dry, oil-free control air to prevent internal switch failure and maintain accuracy over the life of the unit.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The KMC Controls CCE-1001 is a commercial-grade Pneumatic-Electric (P/E) Switch designed for high-reliability HVAC control systems. This SPDT relay switch features a 2 PSI fixed differential, providing precise electrical activation in response to pneumatic pressure changes. Engineered for versatility, the CCE-1001 is a primary choice for starting fan coil units, managing exhaust fans, and industrial electric duct heater control. The unit is housed in a rugged case with a cover to protect the internal switching mechanism from debris and physical damage, ensuring consistent performance in demanding mechanical rooms. Wiring integration is streamlined via two 1/2-inch conduit openings, accommodating standard field installations. As a UL Listed and CSA approved component, it meets rigorous safety standards for 10-amp (125 VAC) or 5-amp (250 VAC) electrical loads. HVAC technicians rely on this KMC P/E switch for its stable switching action and its ability to maintain static pressure setpoints in air handlers and cooling towers without frequent recalibration.
Key Benefits- Precise Pressure Response: The 2# Fixed Differential ensures reliable switching without the hunting issues common in low-tolerance sensors.
- Robust SPDT Configuration: Allows for flexible Single-Pole Double-Throw wiring to manage multiple circuits or alarm states.
- Industrial Durability: Metal case and cover shield the switch mechanism, making it ideal for high-vibration fan coil unit environments.
- Standardized Installation: Dual conduit openings and 3/16" nipples for 1/4" O.D. tubing simplify HVAC replacement tasks.
- Regulatory Compliance: Fully UL and CSA listed, ensuring the part meets building code requirements for commercial electrical relays.
What are the electrical load ratings for the CCE-1001?
The KMC CCE-1001 is rated for 10 amps at 125 VAC and 5 amps at 250 VAC. Always verify your current draw before integrating into electric heater circuits.
Can this switch be used in cooling tower applications?
Yes, this pneumatic-electric switch is commonly utilized for cooling tower and compressor control where a fixed 2 PSI differential is required for operational stability.
Does it require filtered air for operation?
Like all pneumatic controls, the CCE-1001 requires clean, dry, oil-free control air to prevent internal switch failure and maintain accuracy over the life of the unit.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.