As a field technician, you know that the Fireye MAUV1 Amplifier is a critical component for maintaining flame safeguard integrity in Fireye Modular M-SERIES II control systems. This ultraviolet flame amplifier provides reliable monitoring for industrial and commercial burners by processing signals from standard UV scanners like the UV1A, UV2, UV8A, and 45UV3-1050. Specifically engineered for non-self-checking applications, the MAUV1 establishes a Flame Failure Response Time (FFRT) of 2 to 4 seconds, ensuring the system reacts within safety parameters if the pilot or main flame is lost.

The plug-in design allows for rapid installation or replacement directly into the M-Series II chassis without rewiring the base. For commissioning and troubleshooting, the module features built-in test jacks, allowing you to take real-time flame signal measurements with a standard microammeter or digital voltmeter. By incorporating this HVAC flame safeguard module, you ensure high-performance ultraviolent flame detection that meets stringent industrial safety standards while simplifying routine maintenance for the contractor.

Key Benefits
  • Universal M-SERIES II Compatibility: Integrates seamlessly with MC120 and MC230 series chassis for streamlined inventory management.
  • Precise FFRT Timing: Provides the industry-standard 2 to 4 second flame failure response required for diverse burner applications.
  • Scanner Versatility: Compatible with a wide range of scanners, including the Fireye UV1A and 45UV3 series.
  • Field Diagnostics: Front-facing test jacks enable fast signal strength verification, reducing downtime during service calls.
  • Modular Hardware: Reliable solid-state construction designed for the demanding electrical environments of industrial boiler rooms.
Common Questions

Which scanners can I use with the MAUV1 amplifier?
This module is designed for use with Fireye standard non-self-check ultraviolet scanners, including the UV1A, UV2, UV8A, and 45UV3-1050. It cannot be used with self-checking scanners like the 45UV5.

What is the difference between the MAUV1 and the MAUV1T?
The primary difference is the Flame Failure Response Time. The MAUV1 has a standard 2 to 4 second FFRT, while the MAUV1T is designed for applications requiring a faster 0.8-second response.

How do I check the flame signal on this module?
Utilize the test jacks located on the front of the amplifier. A steady reading of 4-10 VDC is typically required for reliable operation, depending on your specific programmer module requirements.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$116.05

Original: $331.58

-65%
Fireye MAUV1 Amplifier

$331.58

$116.05

Fireye MAUV1 Amplifier

As a field technician, you know that the Fireye MAUV1 Amplifier is a critical component for maintaining flame safeguard integrity in Fireye Modular M-SERIES II control systems. This ultraviolet flame amplifier provides reliable monitoring for industrial and commercial burners by processing signals from standard UV scanners like the UV1A, UV2, UV8A, and 45UV3-1050. Specifically engineered for non-self-checking applications, the MAUV1 establishes a Flame Failure Response Time (FFRT) of 2 to 4 seconds, ensuring the system reacts within safety parameters if the pilot or main flame is lost.

The plug-in design allows for rapid installation or replacement directly into the M-Series II chassis without rewiring the base. For commissioning and troubleshooting, the module features built-in test jacks, allowing you to take real-time flame signal measurements with a standard microammeter or digital voltmeter. By incorporating this HVAC flame safeguard module, you ensure high-performance ultraviolent flame detection that meets stringent industrial safety standards while simplifying routine maintenance for the contractor.

Key Benefits
  • Universal M-SERIES II Compatibility: Integrates seamlessly with MC120 and MC230 series chassis for streamlined inventory management.
  • Precise FFRT Timing: Provides the industry-standard 2 to 4 second flame failure response required for diverse burner applications.
  • Scanner Versatility: Compatible with a wide range of scanners, including the Fireye UV1A and 45UV3 series.
  • Field Diagnostics: Front-facing test jacks enable fast signal strength verification, reducing downtime during service calls.
  • Modular Hardware: Reliable solid-state construction designed for the demanding electrical environments of industrial boiler rooms.
Common Questions

Which scanners can I use with the MAUV1 amplifier?
This module is designed for use with Fireye standard non-self-check ultraviolet scanners, including the UV1A, UV2, UV8A, and 45UV3-1050. It cannot be used with self-checking scanners like the 45UV5.

What is the difference between the MAUV1 and the MAUV1T?
The primary difference is the Flame Failure Response Time. The MAUV1 has a standard 2 to 4 second FFRT, while the MAUV1T is designed for applications requiring a faster 0.8-second response.

How do I check the flame signal on this module?
Utilize the test jacks located on the front of the amplifier. A steady reading of 4-10 VDC is typically required for reliable operation, depending on your specific programmer module requirements.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

As a field technician, you know that the Fireye MAUV1 Amplifier is a critical component for maintaining flame safeguard integrity in Fireye Modular M-SERIES II control systems. This ultraviolet flame amplifier provides reliable monitoring for industrial and commercial burners by processing signals from standard UV scanners like the UV1A, UV2, UV8A, and 45UV3-1050. Specifically engineered for non-self-checking applications, the MAUV1 establishes a Flame Failure Response Time (FFRT) of 2 to 4 seconds, ensuring the system reacts within safety parameters if the pilot or main flame is lost.

The plug-in design allows for rapid installation or replacement directly into the M-Series II chassis without rewiring the base. For commissioning and troubleshooting, the module features built-in test jacks, allowing you to take real-time flame signal measurements with a standard microammeter or digital voltmeter. By incorporating this HVAC flame safeguard module, you ensure high-performance ultraviolent flame detection that meets stringent industrial safety standards while simplifying routine maintenance for the contractor.

Key Benefits
  • Universal M-SERIES II Compatibility: Integrates seamlessly with MC120 and MC230 series chassis for streamlined inventory management.
  • Precise FFRT Timing: Provides the industry-standard 2 to 4 second flame failure response required for diverse burner applications.
  • Scanner Versatility: Compatible with a wide range of scanners, including the Fireye UV1A and 45UV3 series.
  • Field Diagnostics: Front-facing test jacks enable fast signal strength verification, reducing downtime during service calls.
  • Modular Hardware: Reliable solid-state construction designed for the demanding electrical environments of industrial boiler rooms.
Common Questions

Which scanners can I use with the MAUV1 amplifier?
This module is designed for use with Fireye standard non-self-check ultraviolet scanners, including the UV1A, UV2, UV8A, and 45UV3-1050. It cannot be used with self-checking scanners like the 45UV5.

What is the difference between the MAUV1 and the MAUV1T?
The primary difference is the Flame Failure Response Time. The MAUV1 has a standard 2 to 4 second FFRT, while the MAUV1T is designed for applications requiring a faster 0.8-second response.

How do I check the flame signal on this module?
Utilize the test jacks located on the front of the amplifier. A steady reading of 4-10 VDC is typically required for reliable operation, depending on your specific programmer module requirements.