Fireye EP260 Module
HomeStore

Fireye EP260 Module

Fireye EP260 Module

The Fireye EP260 is a microprocessor-based plug-in programmer module designed for use with the Flame-Monitor burner management system. This specific module provides a fixed 30-second purge cycle, a selectable 10/15-second trial for ignition (TFI) timing, and is engineered for recycling operation. If a flame failure occurs during the running cycle, the EP260 will initiate a recycle, attempting a full restart starting from the purge period. It is critical for technicians to note that this module integrates seamlessly with the E110 chassis and requires a compatible flame scanner to maintain safety interlocks during the pilot ignition and main flame sequences.

Operating within the FLAME-MONITOR framework, the EP260 manages the sequence of operation including pre-purge, ignition, and flame monitoring. Its robust internal logic ensures that the combustion control process adheres to strict safety timings. For contractors troubleshooting pilot stability or short-cycling issues, the EP260's built-in LED diagnostics provide immediate feedback on the programmed sequence status. This module is standard for industrial boilers and commercial heaters requiring a fireway flame safeguard solution that prioritizes system reliability in high-demand environments.

Key Benefits:

  • Precision Timing: Fixed 30-second purge ensures consistent clearing of the combustion chamber before ignition.
  • Field Serviceability: The plug-in design allows for rapid replacement in the E110 Flame-Monitor chassis, minimizing downtime.
  • Recycle Functionality: Automatically initiates a restart sequence upon flame loss, ideal for applications where nuisance trips must be managed without manual intervention.
  • Compatibility: Designed to work with the Fireye E110, E100, and standard UVM/TUV sensors for comprehensive burnable gas or oil monitoring.

Common Questions:

Can I change the purge timing on the EP260?
No, the EP260 features a factory-preset 30-second purge. If your application requires a different duration, you must select the appropriate programmer module from the EP series, such as the EP160 or EP380.

How does the 'Recycle' function differ from 'Non-Recycle' models?
In a recycle module like the EP260, a loss of flame signal during the running period causes the system to shut down and automatically restart the 10-step sequence. Non-recycle modules (like the EP261) will lock out immediately, requiring a manual reset.

What scanners are compatible with this programmer?
Compatibility depends on the Flame-Monitor chassis and amplifier used, but it typically integrates with UV1A, 45UV5, or flame rods depending on the installed amplifier module.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$2,204.59
Fireye EP260 Module
$2,204.59

Fireye EP260 Module

The Fireye EP260 is a microprocessor-based plug-in programmer module designed for use with the Flame-Monitor burner management system. This specific module provides a fixed 30-second purge cycle, a selectable 10/15-second trial for ignition (TFI) timing, and is engineered for recycling operation. If a flame failure occurs during the running cycle, the EP260 will initiate a recycle, attempting a full restart starting from the purge period. It is critical for technicians to note that this module integrates seamlessly with the E110 chassis and requires a compatible flame scanner to maintain safety interlocks during the pilot ignition and main flame sequences.

Operating within the FLAME-MONITOR framework, the EP260 manages the sequence of operation including pre-purge, ignition, and flame monitoring. Its robust internal logic ensures that the combustion control process adheres to strict safety timings. For contractors troubleshooting pilot stability or short-cycling issues, the EP260's built-in LED diagnostics provide immediate feedback on the programmed sequence status. This module is standard for industrial boilers and commercial heaters requiring a fireway flame safeguard solution that prioritizes system reliability in high-demand environments.

Key Benefits:

  • Precision Timing: Fixed 30-second purge ensures consistent clearing of the combustion chamber before ignition.
  • Field Serviceability: The plug-in design allows for rapid replacement in the E110 Flame-Monitor chassis, minimizing downtime.
  • Recycle Functionality: Automatically initiates a restart sequence upon flame loss, ideal for applications where nuisance trips must be managed without manual intervention.
  • Compatibility: Designed to work with the Fireye E110, E100, and standard UVM/TUV sensors for comprehensive burnable gas or oil monitoring.

Common Questions:

Can I change the purge timing on the EP260?
No, the EP260 features a factory-preset 30-second purge. If your application requires a different duration, you must select the appropriate programmer module from the EP series, such as the EP160 or EP380.

How does the 'Recycle' function differ from 'Non-Recycle' models?
In a recycle module like the EP260, a loss of flame signal during the running period causes the system to shut down and automatically restart the 10-step sequence. Non-recycle modules (like the EP261) will lock out immediately, requiring a manual reset.

What scanners are compatible with this programmer?
Compatibility depends on the Flame-Monitor chassis and amplifier used, but it typically integrates with UV1A, 45UV5, or flame rods depending on the installed amplifier module.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Fireye EP260 is a microprocessor-based plug-in programmer module designed for use with the Flame-Monitor burner management system. This specific module provides a fixed 30-second purge cycle, a selectable 10/15-second trial for ignition (TFI) timing, and is engineered for recycling operation. If a flame failure occurs during the running cycle, the EP260 will initiate a recycle, attempting a full restart starting from the purge period. It is critical for technicians to note that this module integrates seamlessly with the E110 chassis and requires a compatible flame scanner to maintain safety interlocks during the pilot ignition and main flame sequences.

Operating within the FLAME-MONITOR framework, the EP260 manages the sequence of operation including pre-purge, ignition, and flame monitoring. Its robust internal logic ensures that the combustion control process adheres to strict safety timings. For contractors troubleshooting pilot stability or short-cycling issues, the EP260's built-in LED diagnostics provide immediate feedback on the programmed sequence status. This module is standard for industrial boilers and commercial heaters requiring a fireway flame safeguard solution that prioritizes system reliability in high-demand environments.

Key Benefits:

  • Precision Timing: Fixed 30-second purge ensures consistent clearing of the combustion chamber before ignition.
  • Field Serviceability: The plug-in design allows for rapid replacement in the E110 Flame-Monitor chassis, minimizing downtime.
  • Recycle Functionality: Automatically initiates a restart sequence upon flame loss, ideal for applications where nuisance trips must be managed without manual intervention.
  • Compatibility: Designed to work with the Fireye E110, E100, and standard UVM/TUV sensors for comprehensive burnable gas or oil monitoring.

Common Questions:

Can I change the purge timing on the EP260?
No, the EP260 features a factory-preset 30-second purge. If your application requires a different duration, you must select the appropriate programmer module from the EP series, such as the EP160 or EP380.

How does the 'Recycle' function differ from 'Non-Recycle' models?
In a recycle module like the EP260, a loss of flame signal during the running period causes the system to shut down and automatically restart the 10-step sequence. Non-recycle modules (like the EP261) will lock out immediately, requiring a manual reset.

What scanners are compatible with this programmer?
Compatibility depends on the Flame-Monitor chassis and amplifier used, but it typically integrates with UV1A, 45UV5, or flame rods depending on the installed amplifier module.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.