Setra 26410R5WB11T1C Pressure Transducer
The Setra 26410R5WB11T1C is a reliable low differential pressure transducer designed for demanding HVAC, cleanroom, and laboratory airflow monitoring. Featuring a ±0.5" WC bidirectional pressure range and an industry-standard 4–20 mA loop-powered output, this sensor utilizes a micro-TIG welded stainless steel capacitive sensing element for superior long-term stability. The ±1% FS accuracy and high overpressure protection up to 10 PSI make it a durable choice for building automation systems (BAS) and VAV fan control applications. For technicians, the terminal strip and NEMA 1-rated fire-retardant housing allow for efficient installation and integration with unregulated DC power supplies. The device includes accessible zero and span trim pots for field calibration, ensuring accurate air and inert gas monitoring across a wide operating temperature range of 0 to 175°F. Trust the Setra Model 264 series as the core component for filter monitoring and static pressure measurement in critical environments.
Key Benefits for HVACR Applications
- Enhanced Stability: The stainless steel diaphragm and capacitive technology minimize signal drift even in sensitive cleanroom environments.
- Broad Compatibility: Supports a 9–30 VDC supply voltage, making it compatible with most standard HVAC controllers and industrial process systems.
- Simplified Field Service: On-board zero & span adjustments allow for precise calibration without removing the sensor from the wall-mount installation.
- Rugged Reliability: Durable 3/16" brass barbed fittings ensure secure tubing connections and prevent leaks in high-vibration air handlers.
- Bidirectional Versatility: Ideal for monitoring both positive and negative pressure differences across HVAC filters and isolation room barriers.
Common Questions About the Setra 26410R5WB11T1C
How do I install the Setra 26410R5WB11T1C for the best accuracy?
For optimal performance, mount the transducer in a vertical position. Since it is factory-calibrated vertically, installing it at an angle may cause a slight zero shift. Use the accessible zero trim pot to adjust the 12mA baseline (for bidirectional units) after mounting.
Can this pressure sensor be used with liquid media?
No, the Setra 264 series is specifically engineered for use with air and non-conductive gases. Using it with liquids or corrosive gases can damage the internal capacitive element and void its operational integrity.
What is the proper tubing for the process connections?
This model features 1/4" OD (3/16" ID) brass fittings. For best response times, 3/16" ID tubing is recommended for runs up to 100 feet. For longer distances up to 300 feet, 1/4" ID tubing should be used to minimize signal lag.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $207.41
-65%$207.41
$72.59Setra 26410R5WB11T1C Pressure Transducer
The Setra 26410R5WB11T1C is a reliable low differential pressure transducer designed for demanding HVAC, cleanroom, and laboratory airflow monitoring. Featuring a ±0.5" WC bidirectional pressure range and an industry-standard 4–20 mA loop-powered output, this sensor utilizes a micro-TIG welded stainless steel capacitive sensing element for superior long-term stability. The ±1% FS accuracy and high overpressure protection up to 10 PSI make it a durable choice for building automation systems (BAS) and VAV fan control applications. For technicians, the terminal strip and NEMA 1-rated fire-retardant housing allow for efficient installation and integration with unregulated DC power supplies. The device includes accessible zero and span trim pots for field calibration, ensuring accurate air and inert gas monitoring across a wide operating temperature range of 0 to 175°F. Trust the Setra Model 264 series as the core component for filter monitoring and static pressure measurement in critical environments.
Key Benefits for HVACR Applications
- Enhanced Stability: The stainless steel diaphragm and capacitive technology minimize signal drift even in sensitive cleanroom environments.
- Broad Compatibility: Supports a 9–30 VDC supply voltage, making it compatible with most standard HVAC controllers and industrial process systems.
- Simplified Field Service: On-board zero & span adjustments allow for precise calibration without removing the sensor from the wall-mount installation.
- Rugged Reliability: Durable 3/16" brass barbed fittings ensure secure tubing connections and prevent leaks in high-vibration air handlers.
- Bidirectional Versatility: Ideal for monitoring both positive and negative pressure differences across HVAC filters and isolation room barriers.
Common Questions About the Setra 26410R5WB11T1C
How do I install the Setra 26410R5WB11T1C for the best accuracy?
For optimal performance, mount the transducer in a vertical position. Since it is factory-calibrated vertically, installing it at an angle may cause a slight zero shift. Use the accessible zero trim pot to adjust the 12mA baseline (for bidirectional units) after mounting.
Can this pressure sensor be used with liquid media?
No, the Setra 264 series is specifically engineered for use with air and non-conductive gases. Using it with liquids or corrosive gases can damage the internal capacitive element and void its operational integrity.
What is the proper tubing for the process connections?
This model features 1/4" OD (3/16" ID) brass fittings. For best response times, 3/16" ID tubing is recommended for runs up to 100 feet. For longer distances up to 300 feet, 1/4" ID tubing should be used to minimize signal lag.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Setra 26410R5WB11T1C is a reliable low differential pressure transducer designed for demanding HVAC, cleanroom, and laboratory airflow monitoring. Featuring a ±0.5" WC bidirectional pressure range and an industry-standard 4–20 mA loop-powered output, this sensor utilizes a micro-TIG welded stainless steel capacitive sensing element for superior long-term stability. The ±1% FS accuracy and high overpressure protection up to 10 PSI make it a durable choice for building automation systems (BAS) and VAV fan control applications. For technicians, the terminal strip and NEMA 1-rated fire-retardant housing allow for efficient installation and integration with unregulated DC power supplies. The device includes accessible zero and span trim pots for field calibration, ensuring accurate air and inert gas monitoring across a wide operating temperature range of 0 to 175°F. Trust the Setra Model 264 series as the core component for filter monitoring and static pressure measurement in critical environments.
Key Benefits for HVACR Applications
- Enhanced Stability: The stainless steel diaphragm and capacitive technology minimize signal drift even in sensitive cleanroom environments.
- Broad Compatibility: Supports a 9–30 VDC supply voltage, making it compatible with most standard HVAC controllers and industrial process systems.
- Simplified Field Service: On-board zero & span adjustments allow for precise calibration without removing the sensor from the wall-mount installation.
- Rugged Reliability: Durable 3/16" brass barbed fittings ensure secure tubing connections and prevent leaks in high-vibration air handlers.
- Bidirectional Versatility: Ideal for monitoring both positive and negative pressure differences across HVAC filters and isolation room barriers.
Common Questions About the Setra 26410R5WB11T1C
How do I install the Setra 26410R5WB11T1C for the best accuracy?
For optimal performance, mount the transducer in a vertical position. Since it is factory-calibrated vertically, installing it at an angle may cause a slight zero shift. Use the accessible zero trim pot to adjust the 12mA baseline (for bidirectional units) after mounting.
Can this pressure sensor be used with liquid media?
No, the Setra 264 series is specifically engineered for use with air and non-conductive gases. Using it with liquids or corrosive gases can damage the internal capacitive element and void its operational integrity.
What is the proper tubing for the process connections?
This model features 1/4" OD (3/16" ID) brass fittings. For best response times, 3/16" ID tubing is recommended for runs up to 100 feet. For longer distances up to 300 feet, 1/4" ID tubing should be used to minimize signal lag.