Schneider Electric (Viconics) VCM8001V5045 Sensor Module
The Schneider Electric (Viconics) VCM8001V5045 is a field-installable CO2 sensor module engineered for seamless integration with SE8000 Series room controllers. Designed to meet stringent ASHRAE IAQ standards, this NDIR (non-dispersive infrared) sensing element provides precision carbon dioxide monitoring within a range of 400 to 10,000 PPM. The hardware features a 3.4V to 4.5V DC power requirement and utilizes specialized platinum EQC coating to maintain optic performance in variable air environments. For contractors handling demand-controlled ventilation (DCV) retrofits, this module allows for immediate EcoStruxure Building Expert compatibility without full controller replacement. The device operates on a 2 to 7-second measurement interval with a 2-minute response time, ensuring the HVAC indoor air quality logic receives stable, high-resolution data. Maintenance is minimized via a self-correcting automatic baseline algorithm, making it a reliable choice for high-traffic commercial zones.
Key Benefits
- Broad Compatibility: Native pin-header connection for rapid installation in SE8000 and VT8000 series room controllers.
- Advanced NDIR Technology: Reliable infrared sensing prevents common drift issues found in cheaper electrochemical alternatives.
- Automation Ready: Facilitates demand-controlled ventilation to reduce fan energy consumption while maintaining occupant comfort.
- Low Maintenance: Built-in self-calibration logic eliminates the need for manual field gas calibration in standard environments.
- Precise Range: Monitors up to 10,000 PPM, covering commercial, educational, and light industrial requirements.
Common Questions
What is the warm-up period for the VCM8001V5045?
The sensor initializes approximately 30 seconds after the controller is powered, though full accuracy is typically reached after one week of continuous operation as the auto-calibration algorithm stabilizes.
Do I need special tools to install this sensor?
No. The module is designed to snap directly onto the circuit board pins of the room controller. Ensure the unit is powered down before aligning the pins to prevent electrical shorts.
Will this work with the older VT7000 series?
The VCM8001V5045 is specifically designed for the SE8000 and certain VT8000 Series controllers; it is not compatible with legacies like the VT7000 which use different communication architectures.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $288.39
-65%$288.39
$100.94Schneider Electric (Viconics) VCM8001V5045 Sensor Module
The Schneider Electric (Viconics) VCM8001V5045 is a field-installable CO2 sensor module engineered for seamless integration with SE8000 Series room controllers. Designed to meet stringent ASHRAE IAQ standards, this NDIR (non-dispersive infrared) sensing element provides precision carbon dioxide monitoring within a range of 400 to 10,000 PPM. The hardware features a 3.4V to 4.5V DC power requirement and utilizes specialized platinum EQC coating to maintain optic performance in variable air environments. For contractors handling demand-controlled ventilation (DCV) retrofits, this module allows for immediate EcoStruxure Building Expert compatibility without full controller replacement. The device operates on a 2 to 7-second measurement interval with a 2-minute response time, ensuring the HVAC indoor air quality logic receives stable, high-resolution data. Maintenance is minimized via a self-correcting automatic baseline algorithm, making it a reliable choice for high-traffic commercial zones.
Key Benefits
- Broad Compatibility: Native pin-header connection for rapid installation in SE8000 and VT8000 series room controllers.
- Advanced NDIR Technology: Reliable infrared sensing prevents common drift issues found in cheaper electrochemical alternatives.
- Automation Ready: Facilitates demand-controlled ventilation to reduce fan energy consumption while maintaining occupant comfort.
- Low Maintenance: Built-in self-calibration logic eliminates the need for manual field gas calibration in standard environments.
- Precise Range: Monitors up to 10,000 PPM, covering commercial, educational, and light industrial requirements.
Common Questions
What is the warm-up period for the VCM8001V5045?
The sensor initializes approximately 30 seconds after the controller is powered, though full accuracy is typically reached after one week of continuous operation as the auto-calibration algorithm stabilizes.
Do I need special tools to install this sensor?
No. The module is designed to snap directly onto the circuit board pins of the room controller. Ensure the unit is powered down before aligning the pins to prevent electrical shorts.
Will this work with the older VT7000 series?
The VCM8001V5045 is specifically designed for the SE8000 and certain VT8000 Series controllers; it is not compatible with legacies like the VT7000 which use different communication architectures.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Schneider Electric (Viconics) VCM8001V5045 is a field-installable CO2 sensor module engineered for seamless integration with SE8000 Series room controllers. Designed to meet stringent ASHRAE IAQ standards, this NDIR (non-dispersive infrared) sensing element provides precision carbon dioxide monitoring within a range of 400 to 10,000 PPM. The hardware features a 3.4V to 4.5V DC power requirement and utilizes specialized platinum EQC coating to maintain optic performance in variable air environments. For contractors handling demand-controlled ventilation (DCV) retrofits, this module allows for immediate EcoStruxure Building Expert compatibility without full controller replacement. The device operates on a 2 to 7-second measurement interval with a 2-minute response time, ensuring the HVAC indoor air quality logic receives stable, high-resolution data. Maintenance is minimized via a self-correcting automatic baseline algorithm, making it a reliable choice for high-traffic commercial zones.
Key Benefits
- Broad Compatibility: Native pin-header connection for rapid installation in SE8000 and VT8000 series room controllers.
- Advanced NDIR Technology: Reliable infrared sensing prevents common drift issues found in cheaper electrochemical alternatives.
- Automation Ready: Facilitates demand-controlled ventilation to reduce fan energy consumption while maintaining occupant comfort.
- Low Maintenance: Built-in self-calibration logic eliminates the need for manual field gas calibration in standard environments.
- Precise Range: Monitors up to 10,000 PPM, covering commercial, educational, and light industrial requirements.
Common Questions
What is the warm-up period for the VCM8001V5045?
The sensor initializes approximately 30 seconds after the controller is powered, though full accuracy is typically reached after one week of continuous operation as the auto-calibration algorithm stabilizes.
Do I need special tools to install this sensor?
No. The module is designed to snap directly onto the circuit board pins of the room controller. Ensure the unit is powered down before aligning the pins to prevent electrical shorts.
Will this work with the older VT7000 series?
The VCM8001V5045 is specifically designed for the SE8000 and certain VT8000 Series controllers; it is not compatible with legacies like the VT7000 which use different communication architectures.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.