The Resideo W8150A1001 Fresh Air Ventilation Control is a dedicated solution for contractors managing ASHRAE 62.2 indoor air quality requirements in residential applications. Operating on 24 Vac, this logic-driven module automates fresh air intake to balance IAQ and energy efficiency. It features an adjustable 50-160 CFM airflow capacity range, allowing for precise calibration based on specific structure size and occupancy. Specifically optimized for Honeywell fresh air ventilation systems, this controller manages the local HVAC fan and air intake damper to ensure consistent ventilation without over-cooling or over-heating the space. This integration is critical for HVAC duct modifications involving ventilation damper control. By monitoring both the thermostat and equipment run times, the W8150A1001 ensures whole-house mechanical ventilation targets are met reliably. It is a preferred component for professionals requiring HVAC fresh air intake installation within forced-air systems.

Key Benefits
  • System Compatibility: Fully compatible with EARD6 dampers and VNT5150, VNT5200, VNT5070 Series ventilators for seamless integration.
  • ASHRAE Compliance: Designed to meet stringent ASHRAE 62.2 standards, ensuring professional-grade indoor air quality management.
  • Smart Cycling: Optimizes ventilation by leveraging existing equipment run times, reducing total system energy consumption.
  • Adjustable Settings: Features intuitive dials for setting house size, number of bedrooms, and airflow limits, eliminating complex programming.
Common Questions

How do I set the airflow capacity on the W8150A1001 for proper ventilation?
The unit features a dedicated CFM dial. Use a flow hood or pressure drop readings to determine the actual airflow of your intake duct, then align the dial to match that value (between 50 and 160 CFM) to ensure calculation accuracy.

Can this control be used with a heat recovery ventilator (HRV)?
While often paired with standard fresh air dampers, it is specifically engineered to interface with the VNT series and EARD dampers. Always verify the wiring diagram for the specific HRV unit to ensure the 24V signals are compatible with the terminal block.

What happens if the main HVAC fan is already running?
The W8150A1001 monitors the thermostat's G-terminal. If the system is already heating or cooling, the control opens the damper without independently triggering the fan, maximizing efficiency by utilizing scheduled run times.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$45.28

Original: $129.36

-65%
Resideo W8150A1001 Control

$129.36

$45.28

Resideo W8150A1001 Control

The Resideo W8150A1001 Fresh Air Ventilation Control is a dedicated solution for contractors managing ASHRAE 62.2 indoor air quality requirements in residential applications. Operating on 24 Vac, this logic-driven module automates fresh air intake to balance IAQ and energy efficiency. It features an adjustable 50-160 CFM airflow capacity range, allowing for precise calibration based on specific structure size and occupancy. Specifically optimized for Honeywell fresh air ventilation systems, this controller manages the local HVAC fan and air intake damper to ensure consistent ventilation without over-cooling or over-heating the space. This integration is critical for HVAC duct modifications involving ventilation damper control. By monitoring both the thermostat and equipment run times, the W8150A1001 ensures whole-house mechanical ventilation targets are met reliably. It is a preferred component for professionals requiring HVAC fresh air intake installation within forced-air systems.

Key Benefits
  • System Compatibility: Fully compatible with EARD6 dampers and VNT5150, VNT5200, VNT5070 Series ventilators for seamless integration.
  • ASHRAE Compliance: Designed to meet stringent ASHRAE 62.2 standards, ensuring professional-grade indoor air quality management.
  • Smart Cycling: Optimizes ventilation by leveraging existing equipment run times, reducing total system energy consumption.
  • Adjustable Settings: Features intuitive dials for setting house size, number of bedrooms, and airflow limits, eliminating complex programming.
Common Questions

How do I set the airflow capacity on the W8150A1001 for proper ventilation?
The unit features a dedicated CFM dial. Use a flow hood or pressure drop readings to determine the actual airflow of your intake duct, then align the dial to match that value (between 50 and 160 CFM) to ensure calculation accuracy.

Can this control be used with a heat recovery ventilator (HRV)?
While often paired with standard fresh air dampers, it is specifically engineered to interface with the VNT series and EARD dampers. Always verify the wiring diagram for the specific HRV unit to ensure the 24V signals are compatible with the terminal block.

What happens if the main HVAC fan is already running?
The W8150A1001 monitors the thermostat's G-terminal. If the system is already heating or cooling, the control opens the damper without independently triggering the fan, maximizing efficiency by utilizing scheduled run times.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Resideo W8150A1001 Fresh Air Ventilation Control is a dedicated solution for contractors managing ASHRAE 62.2 indoor air quality requirements in residential applications. Operating on 24 Vac, this logic-driven module automates fresh air intake to balance IAQ and energy efficiency. It features an adjustable 50-160 CFM airflow capacity range, allowing for precise calibration based on specific structure size and occupancy. Specifically optimized for Honeywell fresh air ventilation systems, this controller manages the local HVAC fan and air intake damper to ensure consistent ventilation without over-cooling or over-heating the space. This integration is critical for HVAC duct modifications involving ventilation damper control. By monitoring both the thermostat and equipment run times, the W8150A1001 ensures whole-house mechanical ventilation targets are met reliably. It is a preferred component for professionals requiring HVAC fresh air intake installation within forced-air systems.

Key Benefits
  • System Compatibility: Fully compatible with EARD6 dampers and VNT5150, VNT5200, VNT5070 Series ventilators for seamless integration.
  • ASHRAE Compliance: Designed to meet stringent ASHRAE 62.2 standards, ensuring professional-grade indoor air quality management.
  • Smart Cycling: Optimizes ventilation by leveraging existing equipment run times, reducing total system energy consumption.
  • Adjustable Settings: Features intuitive dials for setting house size, number of bedrooms, and airflow limits, eliminating complex programming.
Common Questions

How do I set the airflow capacity on the W8150A1001 for proper ventilation?
The unit features a dedicated CFM dial. Use a flow hood or pressure drop readings to determine the actual airflow of your intake duct, then align the dial to match that value (between 50 and 160 CFM) to ensure calculation accuracy.

Can this control be used with a heat recovery ventilator (HRV)?
While often paired with standard fresh air dampers, it is specifically engineered to interface with the VNT series and EARD dampers. Always verify the wiring diagram for the specific HRV unit to ensure the 24V signals are compatible with the terminal block.

What happens if the main HVAC fan is already running?
The W8150A1001 monitors the thermostat's G-terminal. If the system is already heating or cooling, the control opens the damper without independently triggering the fan, maximizing efficiency by utilizing scheduled run times.