The Resideo Q3450C1185 Pilot Burner is a critical replacement component engineered specifically for high-efficiency Honeywell SmartValve systems. This intermittent pilot assembly facilitates reliable electronic ignition, eliminating the need for a standing pilot. Featuring a Style C bracket and a left-hand front tip orientation, the Q3450C1185 ensures precise flame positioning for optimal main burner lighting. This kit is field-convertible for Natural Gas or Liquid Propane (LP) applications and includes a comprehensive orifice set: BCR-18 (0.018 in.), BCR-20 (0.020 in.), BCR-22 (0.022 in.), and BCR-12 (0.012 in.). Built for durability in high-cycle environments, the assembly includes a 30-inch ignition wire and a 1/4-inch compression fitting for a secure gas connection. Note that the Q3450C1185/U is the identical universal packaging version of this technical specification. Utilizing this OEM-grade HVAC replacement part ensures proper flame rectification signals are returned to the SmartValve controller, preventing nuisance lockouts and ensuring consistent furnace performance under varying manifold pressures.

Key Benefits

  • SmartValve Compatibility: Direct integration with Honeywell SV9500, SV9501, and SV9502 series gas valves for seamless intermittent pilot ignition.
  • Field Flexibility: Includes multiple orifice sizes (BCR-18, BCR-20, BCR-22, BCR-12) to support various BTU ratings and gas types.
  • Extended Reach: Equipped with a 30-inch high-tension lead to accommodate diverse furnace cabinet configurations and reach the ignition module.
  • Precision Flame Pattern: The left-hand tip orientation and Style C bracket ensure accurate burner alignment for efficient combustion.
  • Simplified Installation: Standard 1/4-inch compression fittings allow for rapid field replacement during service calls.

Common Questions

Is the Q3450C1185 compatible with LP gas conversions?
Yes, this pilot burner is designed for both Natural Gas and LP systems. You must swap the orifice to the correct size provided in the kit to match your specific fuel type and BTU requirements.

How do I fix a Honeywell SmartValve pilot not lighting?
First, verify 24V at the valve. If the igniter glows but no pilot flame appears, check for a clogged orifice or a cracked ceramic insulator on the Q3450C1185. If the spark/glow is absent, inspect the 30-inch ignition wire for continuity.

Can I use this to replace a standing pilot assembly?
No, this is an intermittent pilot assembly specifically for SmartValve systems. It requires an electronic control signal to initiate the pilot flow and cannot be used in old-style millivolt or standing pilot furnaces.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$133.89
Resideo Q3450C1185 Pilot Burner
$133.89

Resideo Q3450C1185 Pilot Burner

The Resideo Q3450C1185 Pilot Burner is a critical replacement component engineered specifically for high-efficiency Honeywell SmartValve systems. This intermittent pilot assembly facilitates reliable electronic ignition, eliminating the need for a standing pilot. Featuring a Style C bracket and a left-hand front tip orientation, the Q3450C1185 ensures precise flame positioning for optimal main burner lighting. This kit is field-convertible for Natural Gas or Liquid Propane (LP) applications and includes a comprehensive orifice set: BCR-18 (0.018 in.), BCR-20 (0.020 in.), BCR-22 (0.022 in.), and BCR-12 (0.012 in.). Built for durability in high-cycle environments, the assembly includes a 30-inch ignition wire and a 1/4-inch compression fitting for a secure gas connection. Note that the Q3450C1185/U is the identical universal packaging version of this technical specification. Utilizing this OEM-grade HVAC replacement part ensures proper flame rectification signals are returned to the SmartValve controller, preventing nuisance lockouts and ensuring consistent furnace performance under varying manifold pressures.

Key Benefits

  • SmartValve Compatibility: Direct integration with Honeywell SV9500, SV9501, and SV9502 series gas valves for seamless intermittent pilot ignition.
  • Field Flexibility: Includes multiple orifice sizes (BCR-18, BCR-20, BCR-22, BCR-12) to support various BTU ratings and gas types.
  • Extended Reach: Equipped with a 30-inch high-tension lead to accommodate diverse furnace cabinet configurations and reach the ignition module.
  • Precision Flame Pattern: The left-hand tip orientation and Style C bracket ensure accurate burner alignment for efficient combustion.
  • Simplified Installation: Standard 1/4-inch compression fittings allow for rapid field replacement during service calls.

Common Questions

Is the Q3450C1185 compatible with LP gas conversions?
Yes, this pilot burner is designed for both Natural Gas and LP systems. You must swap the orifice to the correct size provided in the kit to match your specific fuel type and BTU requirements.

How do I fix a Honeywell SmartValve pilot not lighting?
First, verify 24V at the valve. If the igniter glows but no pilot flame appears, check for a clogged orifice or a cracked ceramic insulator on the Q3450C1185. If the spark/glow is absent, inspect the 30-inch ignition wire for continuity.

Can I use this to replace a standing pilot assembly?
No, this is an intermittent pilot assembly specifically for SmartValve systems. It requires an electronic control signal to initiate the pilot flow and cannot be used in old-style millivolt or standing pilot furnaces.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Resideo Q3450C1185 Pilot Burner is a critical replacement component engineered specifically for high-efficiency Honeywell SmartValve systems. This intermittent pilot assembly facilitates reliable electronic ignition, eliminating the need for a standing pilot. Featuring a Style C bracket and a left-hand front tip orientation, the Q3450C1185 ensures precise flame positioning for optimal main burner lighting. This kit is field-convertible for Natural Gas or Liquid Propane (LP) applications and includes a comprehensive orifice set: BCR-18 (0.018 in.), BCR-20 (0.020 in.), BCR-22 (0.022 in.), and BCR-12 (0.012 in.). Built for durability in high-cycle environments, the assembly includes a 30-inch ignition wire and a 1/4-inch compression fitting for a secure gas connection. Note that the Q3450C1185/U is the identical universal packaging version of this technical specification. Utilizing this OEM-grade HVAC replacement part ensures proper flame rectification signals are returned to the SmartValve controller, preventing nuisance lockouts and ensuring consistent furnace performance under varying manifold pressures.

Key Benefits

  • SmartValve Compatibility: Direct integration with Honeywell SV9500, SV9501, and SV9502 series gas valves for seamless intermittent pilot ignition.
  • Field Flexibility: Includes multiple orifice sizes (BCR-18, BCR-20, BCR-22, BCR-12) to support various BTU ratings and gas types.
  • Extended Reach: Equipped with a 30-inch high-tension lead to accommodate diverse furnace cabinet configurations and reach the ignition module.
  • Precision Flame Pattern: The left-hand tip orientation and Style C bracket ensure accurate burner alignment for efficient combustion.
  • Simplified Installation: Standard 1/4-inch compression fittings allow for rapid field replacement during service calls.

Common Questions

Is the Q3450C1185 compatible with LP gas conversions?
Yes, this pilot burner is designed for both Natural Gas and LP systems. You must swap the orifice to the correct size provided in the kit to match your specific fuel type and BTU requirements.

How do I fix a Honeywell SmartValve pilot not lighting?
First, verify 24V at the valve. If the igniter glows but no pilot flame appears, check for a clogged orifice or a cracked ceramic insulator on the Q3450C1185. If the spark/glow is absent, inspect the 30-inch ignition wire for continuity.

Can I use this to replace a standing pilot assembly?
No, this is an intermittent pilot assembly specifically for SmartValve systems. It requires an electronic control signal to initiate the pilot flow and cannot be used in old-style millivolt or standing pilot furnaces.