Resideo AC112-01 Temperature Sensor
HomeStore

Resideo AC112-01 Temperature Sensor

Resideo AC112-01 Temperature Sensor

The Resideo AC112-01 Temperature Sensor is a precision 10k ohm NTC thermistor engineered specifically for radiant floor heating and hydronic slab sensing applications. As a veteran-grade underfloor temperature probe, it provides the critical resistive feedback necessary for thermostats like the Resideo T6 Pro Hydronic or TH115 series to prevent over-temperature conditions in delicate flooring materials. The unit features a 10-foot cable with a flexible casing, allowing for easy pull-through in conduit or direct placement between heating cables. With a standard resistance of 10 k Ohms at 77 degrees Fahrenheit, this replacement floor sensor ensures accurate load shedding and thermal management for high-efficiency electric and hydronic radiant systems. Built for field reliability, the probe maintains a stable resistance curve across a broad operating range, ensuring your radiant heat control remains calibrated to actual subfloor conditions without drift or signal loss over long wire runs.

Key Benefits
  • Universal Compatibility: Optimized for use with Resideo TH114, TH115, and T10+ thermostats as well as AQ2000 series panels.
  • Precise Thermal Monitoring: High-accuracy 10K ohm @ 77F thermistor ensures tighter temperature differentials and improved floor comfort.
  • Heavy-Duty Construction: The 10-foot lead is encased in a flexible jacket designed to withstand the rigors of slab installation.
  • Extended Lead Capacity: Resistance-based signal allows for cable extensions up to 500 feet using 18 AWG wire without significant accuracy loss.
  • Installation Versatility: Suitable for both hydronic temperature sensing on supply/return pipes and traditional slab-integrated placement.
Common Questions

Is this sensor compatible with non-Resideo thermostats?
This 10k floor sensor is compatible with any controller calibrated for a 10k ohm NTC Type II or Type III curve at 77°F. Always verify the resistance-to-temperature chart of your specific thermostat before installation.

Can the 10-foot cable be shortened or lengthened?
Yes, the cable can be cut to length or extended. For extensions over 50 feet, using 18 AWG twisted pair wire is recommended to minimize electromagnetic interference (EMI) in high-voltage environments.

Where should the probe be positioned in a radiant floor?
For best results, place the sensor tip centered between two runs of heating cable or tubing. Avoid placing the probe directly adjacent to outer walls or heat sinks to ensure representative slab temperature readings.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$14.76
Resideo AC112-01 Temperature Sensor
$14.76

Resideo AC112-01 Temperature Sensor

The Resideo AC112-01 Temperature Sensor is a precision 10k ohm NTC thermistor engineered specifically for radiant floor heating and hydronic slab sensing applications. As a veteran-grade underfloor temperature probe, it provides the critical resistive feedback necessary for thermostats like the Resideo T6 Pro Hydronic or TH115 series to prevent over-temperature conditions in delicate flooring materials. The unit features a 10-foot cable with a flexible casing, allowing for easy pull-through in conduit or direct placement between heating cables. With a standard resistance of 10 k Ohms at 77 degrees Fahrenheit, this replacement floor sensor ensures accurate load shedding and thermal management for high-efficiency electric and hydronic radiant systems. Built for field reliability, the probe maintains a stable resistance curve across a broad operating range, ensuring your radiant heat control remains calibrated to actual subfloor conditions without drift or signal loss over long wire runs.

Key Benefits
  • Universal Compatibility: Optimized for use with Resideo TH114, TH115, and T10+ thermostats as well as AQ2000 series panels.
  • Precise Thermal Monitoring: High-accuracy 10K ohm @ 77F thermistor ensures tighter temperature differentials and improved floor comfort.
  • Heavy-Duty Construction: The 10-foot lead is encased in a flexible jacket designed to withstand the rigors of slab installation.
  • Extended Lead Capacity: Resistance-based signal allows for cable extensions up to 500 feet using 18 AWG wire without significant accuracy loss.
  • Installation Versatility: Suitable for both hydronic temperature sensing on supply/return pipes and traditional slab-integrated placement.
Common Questions

Is this sensor compatible with non-Resideo thermostats?
This 10k floor sensor is compatible with any controller calibrated for a 10k ohm NTC Type II or Type III curve at 77°F. Always verify the resistance-to-temperature chart of your specific thermostat before installation.

Can the 10-foot cable be shortened or lengthened?
Yes, the cable can be cut to length or extended. For extensions over 50 feet, using 18 AWG twisted pair wire is recommended to minimize electromagnetic interference (EMI) in high-voltage environments.

Where should the probe be positioned in a radiant floor?
For best results, place the sensor tip centered between two runs of heating cable or tubing. Avoid placing the probe directly adjacent to outer walls or heat sinks to ensure representative slab temperature readings.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Resideo AC112-01 Temperature Sensor is a precision 10k ohm NTC thermistor engineered specifically for radiant floor heating and hydronic slab sensing applications. As a veteran-grade underfloor temperature probe, it provides the critical resistive feedback necessary for thermostats like the Resideo T6 Pro Hydronic or TH115 series to prevent over-temperature conditions in delicate flooring materials. The unit features a 10-foot cable with a flexible casing, allowing for easy pull-through in conduit or direct placement between heating cables. With a standard resistance of 10 k Ohms at 77 degrees Fahrenheit, this replacement floor sensor ensures accurate load shedding and thermal management for high-efficiency electric and hydronic radiant systems. Built for field reliability, the probe maintains a stable resistance curve across a broad operating range, ensuring your radiant heat control remains calibrated to actual subfloor conditions without drift or signal loss over long wire runs.

Key Benefits
  • Universal Compatibility: Optimized for use with Resideo TH114, TH115, and T10+ thermostats as well as AQ2000 series panels.
  • Precise Thermal Monitoring: High-accuracy 10K ohm @ 77F thermistor ensures tighter temperature differentials and improved floor comfort.
  • Heavy-Duty Construction: The 10-foot lead is encased in a flexible jacket designed to withstand the rigors of slab installation.
  • Extended Lead Capacity: Resistance-based signal allows for cable extensions up to 500 feet using 18 AWG wire without significant accuracy loss.
  • Installation Versatility: Suitable for both hydronic temperature sensing on supply/return pipes and traditional slab-integrated placement.
Common Questions

Is this sensor compatible with non-Resideo thermostats?
This 10k floor sensor is compatible with any controller calibrated for a 10k ohm NTC Type II or Type III curve at 77°F. Always verify the resistance-to-temperature chart of your specific thermostat before installation.

Can the 10-foot cable be shortened or lengthened?
Yes, the cable can be cut to length or extended. For extensions over 50 feet, using 18 AWG twisted pair wire is recommended to minimize electromagnetic interference (EMI) in high-voltage environments.

Where should the probe be positioned in a radiant floor?
For best results, place the sensor tip centered between two runs of heating cable or tubing. Avoid placing the probe directly adjacent to outer walls or heat sinks to ensure representative slab temperature readings.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Resideo AC112-01 Temperature Sensor | GSIstore