The Laars Heating Systems RW0034500 Burner Assembly is a critical combustion component engineered for high-performance residential and commercial hydronic boilers. This OEM pilot burner assembly features an integrated spark ignition system designed for seamless natural gas pilot burner operation, ensuring a consistent and stable flame for main burner initiation. Built to handle the high-thermal environments of modern sealed-combustion chambers, the assembly includes a durable mounting bracket and spark ignition pilot electrode to minimize ignition failure and lockout codes.

As a veteran tech, you know that a compromised pilot can lead to irregular ignition cycles or complete system failure. Replacing the aging unit with this authentic Laars replacement part restores the precise millivolt signal or flame rectification required by the control module. Designed for Laars boiler repair, this assembly's compact footprint allows for straightforward installation in tight transition assemblies. By maintaining the correct 3/16-inch gap between the spark rod and ground, you ensure reliable performance even under fluctuating inlet pressures.

Key Benefits
  • Direct OEM Compatibility: Ensures exact fit and specific gas flow rates for Laars heating units, preventing improper fuel-to-air ratios.
  • Enhanced Ignition Reliability: The factory-set spark ignition electrode provides a high-voltage arc for immediate pilot lighting.
  • Robust Construction: Resists thermal stresses and oxidation common in gas-fired copper-tube boilers and water heaters.
  • Stable Flame Production: Optimized burner ports provide a concentrated flame for reliable main burner crossover.
Common Questions
  • Is this assembly compatible with propane (LP) systems? This specific model is configured for natural gas; using it with propane requires the installation of a manufacturer-approved LP orifice.
  • Does this include the flame sensor? This configuration typically includes the integrated spark rod/electrode; verify if your specific control board requires a separate 3-wire sensor or relies on flame rectification through this assembly.
  • How do I resolve a 'no pilot flame' error? First, check for 24VAC at the gas valve and inspect the Laars RW0034500 for carbon buildup or cracked ceramics that could cause a ground short.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$87.12

Original: $248.92

-65%
Laars Heating Systems RW0034500 Burner Assembly

$248.92

$87.12

Laars Heating Systems RW0034500 Burner Assembly

The Laars Heating Systems RW0034500 Burner Assembly is a critical combustion component engineered for high-performance residential and commercial hydronic boilers. This OEM pilot burner assembly features an integrated spark ignition system designed for seamless natural gas pilot burner operation, ensuring a consistent and stable flame for main burner initiation. Built to handle the high-thermal environments of modern sealed-combustion chambers, the assembly includes a durable mounting bracket and spark ignition pilot electrode to minimize ignition failure and lockout codes.

As a veteran tech, you know that a compromised pilot can lead to irregular ignition cycles or complete system failure. Replacing the aging unit with this authentic Laars replacement part restores the precise millivolt signal or flame rectification required by the control module. Designed for Laars boiler repair, this assembly's compact footprint allows for straightforward installation in tight transition assemblies. By maintaining the correct 3/16-inch gap between the spark rod and ground, you ensure reliable performance even under fluctuating inlet pressures.

Key Benefits
  • Direct OEM Compatibility: Ensures exact fit and specific gas flow rates for Laars heating units, preventing improper fuel-to-air ratios.
  • Enhanced Ignition Reliability: The factory-set spark ignition electrode provides a high-voltage arc for immediate pilot lighting.
  • Robust Construction: Resists thermal stresses and oxidation common in gas-fired copper-tube boilers and water heaters.
  • Stable Flame Production: Optimized burner ports provide a concentrated flame for reliable main burner crossover.
Common Questions
  • Is this assembly compatible with propane (LP) systems? This specific model is configured for natural gas; using it with propane requires the installation of a manufacturer-approved LP orifice.
  • Does this include the flame sensor? This configuration typically includes the integrated spark rod/electrode; verify if your specific control board requires a separate 3-wire sensor or relies on flame rectification through this assembly.
  • How do I resolve a 'no pilot flame' error? First, check for 24VAC at the gas valve and inspect the Laars RW0034500 for carbon buildup or cracked ceramics that could cause a ground short.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Laars Heating Systems RW0034500 Burner Assembly is a critical combustion component engineered for high-performance residential and commercial hydronic boilers. This OEM pilot burner assembly features an integrated spark ignition system designed for seamless natural gas pilot burner operation, ensuring a consistent and stable flame for main burner initiation. Built to handle the high-thermal environments of modern sealed-combustion chambers, the assembly includes a durable mounting bracket and spark ignition pilot electrode to minimize ignition failure and lockout codes.

As a veteran tech, you know that a compromised pilot can lead to irregular ignition cycles or complete system failure. Replacing the aging unit with this authentic Laars replacement part restores the precise millivolt signal or flame rectification required by the control module. Designed for Laars boiler repair, this assembly's compact footprint allows for straightforward installation in tight transition assemblies. By maintaining the correct 3/16-inch gap between the spark rod and ground, you ensure reliable performance even under fluctuating inlet pressures.

Key Benefits
  • Direct OEM Compatibility: Ensures exact fit and specific gas flow rates for Laars heating units, preventing improper fuel-to-air ratios.
  • Enhanced Ignition Reliability: The factory-set spark ignition electrode provides a high-voltage arc for immediate pilot lighting.
  • Robust Construction: Resists thermal stresses and oxidation common in gas-fired copper-tube boilers and water heaters.
  • Stable Flame Production: Optimized burner ports provide a concentrated flame for reliable main burner crossover.
Common Questions
  • Is this assembly compatible with propane (LP) systems? This specific model is configured for natural gas; using it with propane requires the installation of a manufacturer-approved LP orifice.
  • Does this include the flame sensor? This configuration typically includes the integrated spark rod/electrode; verify if your specific control board requires a separate 3-wire sensor or relies on flame rectification through this assembly.
  • How do I resolve a 'no pilot flame' error? First, check for 24VAC at the gas valve and inspect the Laars RW0034500 for carbon buildup or cracked ceramics that could cause a ground short.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Laars Heating Systems RW0034500 Burner Assembly | GSIstore