Laars Heating Systems RE2058300 Aquastat Well
HomeStore

Laars Heating Systems RE2058300 Aquastat Well

Laars Heating Systems RE2058300 Aquastat Well

The Laars Heating Systems RE2058300 Aquastat Well is a critical OEM replacement part designed for integration into commercial and residential hydronic heating systems. Built to provide a sealed environment for temperature-sensing bulbs, this 1/2" NPT male aquastat well ensures the protection of the internal sensor from direct fluid contact while maintaining high thermal conductivity for precise cycling. The RE2058300 is precision-machined with MNPT (Male National Pipe Thread) sizing to facilitate a leak-proof seal within the boiler or manifold tap. This component is essential for technicians performing maintenance on Laars boilers where accurate high-limit or operating temperature sensing is required for system safety and fuel efficiency.

Key Benefits for Technicians:

  • Direct OEM Compatibility: Verified as a genuine Laars RE2058300 component for seamless fitment in specific Laars boiler models.
  • Robust Construction: Engineered to withstand the thermal stressors and pressure fluctuations common in hydronic heating systems.
  • Standardized Threading: Features a 1/2" MNPT connection for universal compatibility with standard boiler tapping ports.
  • Enhanced Sensor Protection: Effectively isolates the temperature sensor from corrosive system water and scale buildup.
  • Optimized Heat Transfer: Designed with wall thickness specifications that prioritize rapid response times for the aquastat temperature well.

Common Questions & Technical Insights:

What is the primary function of the Laars RE2058300 Aquastat Well?
This well serves as a protective sleeve for an aquastat bulb or sensor. It allows the sensor to monitor water temperature without being submerged in the system fluid, enabling sensor replacement without draining the boiler.

Is this well compatible with non-Laars equipment?
While designed as a Laars OEM replacement part, its 1/2" NPT Male Aquastat threading and internal depth may fit other applications; however, technicians should verify immersion depth and internal diameter against the specific sensor bulb dimensions before installation.

Does the installation require pipe sealant?
Yes, per standard HVACR practices, use a high-quality pipe dope or PTFE tape rated for high-temperature heating applications on the MNPT aquastat fitting to ensure a permanent, leak-free connection.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$30.59

Original: $87.39

-65%
Laars Heating Systems RE2058300 Aquastat Well

$87.39

$30.59

Laars Heating Systems RE2058300 Aquastat Well

The Laars Heating Systems RE2058300 Aquastat Well is a critical OEM replacement part designed for integration into commercial and residential hydronic heating systems. Built to provide a sealed environment for temperature-sensing bulbs, this 1/2" NPT male aquastat well ensures the protection of the internal sensor from direct fluid contact while maintaining high thermal conductivity for precise cycling. The RE2058300 is precision-machined with MNPT (Male National Pipe Thread) sizing to facilitate a leak-proof seal within the boiler or manifold tap. This component is essential for technicians performing maintenance on Laars boilers where accurate high-limit or operating temperature sensing is required for system safety and fuel efficiency.

Key Benefits for Technicians:

  • Direct OEM Compatibility: Verified as a genuine Laars RE2058300 component for seamless fitment in specific Laars boiler models.
  • Robust Construction: Engineered to withstand the thermal stressors and pressure fluctuations common in hydronic heating systems.
  • Standardized Threading: Features a 1/2" MNPT connection for universal compatibility with standard boiler tapping ports.
  • Enhanced Sensor Protection: Effectively isolates the temperature sensor from corrosive system water and scale buildup.
  • Optimized Heat Transfer: Designed with wall thickness specifications that prioritize rapid response times for the aquastat temperature well.

Common Questions & Technical Insights:

What is the primary function of the Laars RE2058300 Aquastat Well?
This well serves as a protective sleeve for an aquastat bulb or sensor. It allows the sensor to monitor water temperature without being submerged in the system fluid, enabling sensor replacement without draining the boiler.

Is this well compatible with non-Laars equipment?
While designed as a Laars OEM replacement part, its 1/2" NPT Male Aquastat threading and internal depth may fit other applications; however, technicians should verify immersion depth and internal diameter against the specific sensor bulb dimensions before installation.

Does the installation require pipe sealant?
Yes, per standard HVACR practices, use a high-quality pipe dope or PTFE tape rated for high-temperature heating applications on the MNPT aquastat fitting to ensure a permanent, leak-free connection.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Laars Heating Systems RE2058300 Aquastat Well is a critical OEM replacement part designed for integration into commercial and residential hydronic heating systems. Built to provide a sealed environment for temperature-sensing bulbs, this 1/2" NPT male aquastat well ensures the protection of the internal sensor from direct fluid contact while maintaining high thermal conductivity for precise cycling. The RE2058300 is precision-machined with MNPT (Male National Pipe Thread) sizing to facilitate a leak-proof seal within the boiler or manifold tap. This component is essential for technicians performing maintenance on Laars boilers where accurate high-limit or operating temperature sensing is required for system safety and fuel efficiency.

Key Benefits for Technicians:

  • Direct OEM Compatibility: Verified as a genuine Laars RE2058300 component for seamless fitment in specific Laars boiler models.
  • Robust Construction: Engineered to withstand the thermal stressors and pressure fluctuations common in hydronic heating systems.
  • Standardized Threading: Features a 1/2" MNPT connection for universal compatibility with standard boiler tapping ports.
  • Enhanced Sensor Protection: Effectively isolates the temperature sensor from corrosive system water and scale buildup.
  • Optimized Heat Transfer: Designed with wall thickness specifications that prioritize rapid response times for the aquastat temperature well.

Common Questions & Technical Insights:

What is the primary function of the Laars RE2058300 Aquastat Well?
This well serves as a protective sleeve for an aquastat bulb or sensor. It allows the sensor to monitor water temperature without being submerged in the system fluid, enabling sensor replacement without draining the boiler.

Is this well compatible with non-Laars equipment?
While designed as a Laars OEM replacement part, its 1/2" NPT Male Aquastat threading and internal depth may fit other applications; however, technicians should verify immersion depth and internal diameter against the specific sensor bulb dimensions before installation.

Does the installation require pipe sealant?
Yes, per standard HVACR practices, use a high-quality pipe dope or PTFE tape rated for high-temperature heating applications on the MNPT aquastat fitting to ensure a permanent, leak-free connection.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.