The Laars Heating Systems R0456900 Ignition Module is a critical direct-fit replacement for ensuring precise sequence control in high-efficiency heating applications. As a hot surface ignition (HSI) control, this module is engineered for compatibility with Jandy JXi and LXi Low NOx heaters, as well as several Laars and Zodiac heating systems including the Legacy LRZM series. It functions by monitoring the flame sensor, limit switches, and pressure switches to safely manage energy delivery to the gas valve and igniter. If you are troubleshooting a failed ignition sequence or an AGS service code, replacing a faulty intermittent pilot or HSI control board with this genuine OEM part ensures proper flame rectification and system timing. This Fenwal 35-665942-113-0G cross-reference allows for seamless integration into 120VAC or 24VAC control circuits, maintaining the strict safety parameters required for industrial and residential pool or hydronic boiler operation.

Key Benefits
  • Direct OEM Compatibility: Verified replacement for Jandy R0456900 and Fenwal 35-665942-113-0G controllers.
  • Advanced Diagnostics: Integrates with existing system sensors to provide accurate fault monitoring for pressure switches and vent safeties.
  • Durable Construction: Built to withstand the high-temperature environments of Low NOx pool heaters and commercial boilers.
  • Optimized Ignition Timing: Precision-engineered for consistent hot surface element heat-up and reliable gas valve actuation.
Common Questions
  • Will this module fix an 'AGS' or 'Service' error code? While these codes often suggest flame rectification issues, this module is the primary controller for that process; however, verify the flame sensor and hot surface igniter integrity during installation.
  • Can I use this for both Natural Gas and Propane units? Yes, the R0456900 ignition module is designed to manage the ignition sequence regardless of gas type, provided the heater's orifices and valves are correctly configured.
  • Is this compatible with the Jandy LXi 400 model? Yes, it is a standard component for the Jandy LXi and JXi series, including the 200, 260, and 400 BTU models.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$597.32
Laars Heating Systems R0456900 Ignition Module
$597.32

Laars Heating Systems R0456900 Ignition Module

The Laars Heating Systems R0456900 Ignition Module is a critical direct-fit replacement for ensuring precise sequence control in high-efficiency heating applications. As a hot surface ignition (HSI) control, this module is engineered for compatibility with Jandy JXi and LXi Low NOx heaters, as well as several Laars and Zodiac heating systems including the Legacy LRZM series. It functions by monitoring the flame sensor, limit switches, and pressure switches to safely manage energy delivery to the gas valve and igniter. If you are troubleshooting a failed ignition sequence or an AGS service code, replacing a faulty intermittent pilot or HSI control board with this genuine OEM part ensures proper flame rectification and system timing. This Fenwal 35-665942-113-0G cross-reference allows for seamless integration into 120VAC or 24VAC control circuits, maintaining the strict safety parameters required for industrial and residential pool or hydronic boiler operation.

Key Benefits
  • Direct OEM Compatibility: Verified replacement for Jandy R0456900 and Fenwal 35-665942-113-0G controllers.
  • Advanced Diagnostics: Integrates with existing system sensors to provide accurate fault monitoring for pressure switches and vent safeties.
  • Durable Construction: Built to withstand the high-temperature environments of Low NOx pool heaters and commercial boilers.
  • Optimized Ignition Timing: Precision-engineered for consistent hot surface element heat-up and reliable gas valve actuation.
Common Questions
  • Will this module fix an 'AGS' or 'Service' error code? While these codes often suggest flame rectification issues, this module is the primary controller for that process; however, verify the flame sensor and hot surface igniter integrity during installation.
  • Can I use this for both Natural Gas and Propane units? Yes, the R0456900 ignition module is designed to manage the ignition sequence regardless of gas type, provided the heater's orifices and valves are correctly configured.
  • Is this compatible with the Jandy LXi 400 model? Yes, it is a standard component for the Jandy LXi and JXi series, including the 200, 260, and 400 BTU models.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Laars Heating Systems R0456900 Ignition Module is a critical direct-fit replacement for ensuring precise sequence control in high-efficiency heating applications. As a hot surface ignition (HSI) control, this module is engineered for compatibility with Jandy JXi and LXi Low NOx heaters, as well as several Laars and Zodiac heating systems including the Legacy LRZM series. It functions by monitoring the flame sensor, limit switches, and pressure switches to safely manage energy delivery to the gas valve and igniter. If you are troubleshooting a failed ignition sequence or an AGS service code, replacing a faulty intermittent pilot or HSI control board with this genuine OEM part ensures proper flame rectification and system timing. This Fenwal 35-665942-113-0G cross-reference allows for seamless integration into 120VAC or 24VAC control circuits, maintaining the strict safety parameters required for industrial and residential pool or hydronic boiler operation.

Key Benefits
  • Direct OEM Compatibility: Verified replacement for Jandy R0456900 and Fenwal 35-665942-113-0G controllers.
  • Advanced Diagnostics: Integrates with existing system sensors to provide accurate fault monitoring for pressure switches and vent safeties.
  • Durable Construction: Built to withstand the high-temperature environments of Low NOx pool heaters and commercial boilers.
  • Optimized Ignition Timing: Precision-engineered for consistent hot surface element heat-up and reliable gas valve actuation.
Common Questions
  • Will this module fix an 'AGS' or 'Service' error code? While these codes often suggest flame rectification issues, this module is the primary controller for that process; however, verify the flame sensor and hot surface igniter integrity during installation.
  • Can I use this for both Natural Gas and Propane units? Yes, the R0456900 ignition module is designed to manage the ignition sequence regardless of gas type, provided the heater's orifices and valves are correctly configured.
  • Is this compatible with the Jandy LXi 400 model? Yes, it is a standard component for the Jandy LXi and JXi series, including the 200, 260, and 400 BTU models.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Laars Heating Systems R0456900 Ignition Module | GSIstore