Laars Heating Systems R0096700 Pilot Assembly
HomeStore

Laars Heating Systems R0096700 Pilot Assembly

Laars Heating Systems R0096700 Pilot Assembly

The Laars Heating Systems R0096700 Pilot Assembly is a direct replacement natural gas pilot burner designed for high-performance residential and commercial heating applications. Engineered for compatibility with Laars EC and EPC model heaters (sizes 125 through 400), this assembly ensures a stable, continuous pilot flame for reliable main burner ignition. As a veteran technician knows, maintaining the integrity of the pilot signal is critical for preventing soft lockouts and ignition failure error codes (E11). This OEM-spec component features a robust metal construction and includes the necessary orifice and bracketry for a secure fit within the combustion chamber. Whether you are servicing a Zodiac Laars Lite or a standard ESG series unit, this assembly provides the precise gas flow and millivolt output required to interface seamlessly with your existing gas valve and flame sensor circuitry.

Key Benefits
  • Broad Compatibility: Fits a wide range of Laars Heating Systems models, specifically the EC 125-400 and EPC 125-400 series.
  • Optimized Ignition: Provides a stable flame pattern to ensure consistent natural gas ignition and reduce nuisance service calls.
  • Heavy-Duty Construction: Built with high-grade materials to withstand the thermal stress of high-output boiler environments.
  • Simplified Maintenance: Direct-fit replacement reduces labor time during annual cleanings or thermocouple/pilot generator swaps.
Common Questions

Is this pilot assembly compatible with Liquid Propane (LP) units?
No, the R0096700 is calibrated specifically for natural gas pilot assembly applications. Using this on an LP system without a proper orifice conversion can lead to improper combustion.

What should I check if the pilot flame is lit but the main burner won't engage?
First, verify millivolt output from the pilot generator. Ensure the flame is properly engulfing the sensor/thermocouple and that there is no debris on the burner plate obstructing the signal to the control board.

Does this assembly include the ceramic insulator?
Yes, this professional-grade kit typically includes the pilot burner, orifice, and the required ceramic insulator with bracketry for a complete field replacement.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$92.87

Original: $265.35

-65%
Laars Heating Systems R0096700 Pilot Assembly

$265.35

$92.87

Laars Heating Systems R0096700 Pilot Assembly

The Laars Heating Systems R0096700 Pilot Assembly is a direct replacement natural gas pilot burner designed for high-performance residential and commercial heating applications. Engineered for compatibility with Laars EC and EPC model heaters (sizes 125 through 400), this assembly ensures a stable, continuous pilot flame for reliable main burner ignition. As a veteran technician knows, maintaining the integrity of the pilot signal is critical for preventing soft lockouts and ignition failure error codes (E11). This OEM-spec component features a robust metal construction and includes the necessary orifice and bracketry for a secure fit within the combustion chamber. Whether you are servicing a Zodiac Laars Lite or a standard ESG series unit, this assembly provides the precise gas flow and millivolt output required to interface seamlessly with your existing gas valve and flame sensor circuitry.

Key Benefits
  • Broad Compatibility: Fits a wide range of Laars Heating Systems models, specifically the EC 125-400 and EPC 125-400 series.
  • Optimized Ignition: Provides a stable flame pattern to ensure consistent natural gas ignition and reduce nuisance service calls.
  • Heavy-Duty Construction: Built with high-grade materials to withstand the thermal stress of high-output boiler environments.
  • Simplified Maintenance: Direct-fit replacement reduces labor time during annual cleanings or thermocouple/pilot generator swaps.
Common Questions

Is this pilot assembly compatible with Liquid Propane (LP) units?
No, the R0096700 is calibrated specifically for natural gas pilot assembly applications. Using this on an LP system without a proper orifice conversion can lead to improper combustion.

What should I check if the pilot flame is lit but the main burner won't engage?
First, verify millivolt output from the pilot generator. Ensure the flame is properly engulfing the sensor/thermocouple and that there is no debris on the burner plate obstructing the signal to the control board.

Does this assembly include the ceramic insulator?
Yes, this professional-grade kit typically includes the pilot burner, orifice, and the required ceramic insulator with bracketry for a complete field replacement.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Laars Heating Systems R0096700 Pilot Assembly is a direct replacement natural gas pilot burner designed for high-performance residential and commercial heating applications. Engineered for compatibility with Laars EC and EPC model heaters (sizes 125 through 400), this assembly ensures a stable, continuous pilot flame for reliable main burner ignition. As a veteran technician knows, maintaining the integrity of the pilot signal is critical for preventing soft lockouts and ignition failure error codes (E11). This OEM-spec component features a robust metal construction and includes the necessary orifice and bracketry for a secure fit within the combustion chamber. Whether you are servicing a Zodiac Laars Lite or a standard ESG series unit, this assembly provides the precise gas flow and millivolt output required to interface seamlessly with your existing gas valve and flame sensor circuitry.

Key Benefits
  • Broad Compatibility: Fits a wide range of Laars Heating Systems models, specifically the EC 125-400 and EPC 125-400 series.
  • Optimized Ignition: Provides a stable flame pattern to ensure consistent natural gas ignition and reduce nuisance service calls.
  • Heavy-Duty Construction: Built with high-grade materials to withstand the thermal stress of high-output boiler environments.
  • Simplified Maintenance: Direct-fit replacement reduces labor time during annual cleanings or thermocouple/pilot generator swaps.
Common Questions

Is this pilot assembly compatible with Liquid Propane (LP) units?
No, the R0096700 is calibrated specifically for natural gas pilot assembly applications. Using this on an LP system without a proper orifice conversion can lead to improper combustion.

What should I check if the pilot flame is lit but the main burner won't engage?
First, verify millivolt output from the pilot generator. Ensure the flame is properly engulfing the sensor/thermocouple and that there is no debris on the burner plate obstructing the signal to the control board.

Does this assembly include the ceramic insulator?
Yes, this professional-grade kit typically includes the pilot burner, orifice, and the required ceramic insulator with bracketry for a complete field replacement.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Laars Heating Systems R0096700 Pilot Assembly | GSIstore