Heil Quaker ICP 1192604 TXV Valve
The Heil Quaker ICP 1192604 TXV Valve is a critical OEM thermostatic expansion valve kit engineered specifically for 2-ton R410A refrigerant systems. Designed for precise superheat control, this replacement kit ensures that the evaporator coil receives the exact volume of liquid refrigerant required for the current cooling load, mitigating the risk of liquid floodback and subsequent compressor damage. This bolt-on TXV replacement kit is compatible with a wide range of International Comfort Products (ICP) equipment, including air handlers and flex coils, facilitating improved energy efficiency and system stability in both heat pump and straight-cool applications.
Veteran technicians recognize the ICP 1192604 as a necessary component for maintaining rated SEER levels. The kit includes the 2-ton expansion valve, thermal insulation, sensing bulb straps, and the required Teflon washer for a secure seal. By modulating refrigerant flow based on temperature and pressure, this thermal expansion valve maintains optimal heat exchange across the evaporator, ensuring consistent indoor comfort and reduced operational wear on the entire refrigerant circuit.
Key Benefits
- Precise Refrigerant Metering: Automatically adjusts flow to maintain optimal superheat, preventing evaporator coil icing or compressor liquid slugging.
- R410A Optimization: Specifically calibrated for R-410A systems to maximize thermal efficiency and cooling performance.
- OEM Compatibility: Genuine ICP (Heil Quaker) replacement ensures exact fitment for 2-ton residential and light commercial equipment.
- Complete Installation Kit: Includes sensing bulb thermal insulation and bulb clamps to ensure accurate temperature sensing on the suction line.
Common Questions
Is a hard start kit required when installing the 1192604 TXV?
While the 1192604 improves efficiency, the installation of a thermal expansion valve may necessitate a hard start kit (capacitor and relay) if the outdoor unit does not already have one, as the TXV does not bleed pressure during the off-cycle.
Can this kit be used on 1.5-ton or 2.5-ton systems?
No, this valve is fixed for 2-ton capacity. Using a mismatched TXV will lead to improper refrigerant flow, poor oil return, and potential system failure.
What is the correct mounting position for the sensing bulb?
On a horizontal vapor line, the sensing bulb should be mounted at the 10 o'clock or 2 o'clock position to ensure it reads the refrigerant temperature and not the oil traveling along the bottom of the pipe.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $119.29
-65%$119.29
$41.75Heil Quaker ICP 1192604 TXV Valve
The Heil Quaker ICP 1192604 TXV Valve is a critical OEM thermostatic expansion valve kit engineered specifically for 2-ton R410A refrigerant systems. Designed for precise superheat control, this replacement kit ensures that the evaporator coil receives the exact volume of liquid refrigerant required for the current cooling load, mitigating the risk of liquid floodback and subsequent compressor damage. This bolt-on TXV replacement kit is compatible with a wide range of International Comfort Products (ICP) equipment, including air handlers and flex coils, facilitating improved energy efficiency and system stability in both heat pump and straight-cool applications.
Veteran technicians recognize the ICP 1192604 as a necessary component for maintaining rated SEER levels. The kit includes the 2-ton expansion valve, thermal insulation, sensing bulb straps, and the required Teflon washer for a secure seal. By modulating refrigerant flow based on temperature and pressure, this thermal expansion valve maintains optimal heat exchange across the evaporator, ensuring consistent indoor comfort and reduced operational wear on the entire refrigerant circuit.
Key Benefits
- Precise Refrigerant Metering: Automatically adjusts flow to maintain optimal superheat, preventing evaporator coil icing or compressor liquid slugging.
- R410A Optimization: Specifically calibrated for R-410A systems to maximize thermal efficiency and cooling performance.
- OEM Compatibility: Genuine ICP (Heil Quaker) replacement ensures exact fitment for 2-ton residential and light commercial equipment.
- Complete Installation Kit: Includes sensing bulb thermal insulation and bulb clamps to ensure accurate temperature sensing on the suction line.
Common Questions
Is a hard start kit required when installing the 1192604 TXV?
While the 1192604 improves efficiency, the installation of a thermal expansion valve may necessitate a hard start kit (capacitor and relay) if the outdoor unit does not already have one, as the TXV does not bleed pressure during the off-cycle.
Can this kit be used on 1.5-ton or 2.5-ton systems?
No, this valve is fixed for 2-ton capacity. Using a mismatched TXV will lead to improper refrigerant flow, poor oil return, and potential system failure.
What is the correct mounting position for the sensing bulb?
On a horizontal vapor line, the sensing bulb should be mounted at the 10 o'clock or 2 o'clock position to ensure it reads the refrigerant temperature and not the oil traveling along the bottom of the pipe.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Heil Quaker ICP 1192604 TXV Valve is a critical OEM thermostatic expansion valve kit engineered specifically for 2-ton R410A refrigerant systems. Designed for precise superheat control, this replacement kit ensures that the evaporator coil receives the exact volume of liquid refrigerant required for the current cooling load, mitigating the risk of liquid floodback and subsequent compressor damage. This bolt-on TXV replacement kit is compatible with a wide range of International Comfort Products (ICP) equipment, including air handlers and flex coils, facilitating improved energy efficiency and system stability in both heat pump and straight-cool applications.
Veteran technicians recognize the ICP 1192604 as a necessary component for maintaining rated SEER levels. The kit includes the 2-ton expansion valve, thermal insulation, sensing bulb straps, and the required Teflon washer for a secure seal. By modulating refrigerant flow based on temperature and pressure, this thermal expansion valve maintains optimal heat exchange across the evaporator, ensuring consistent indoor comfort and reduced operational wear on the entire refrigerant circuit.
Key Benefits
- Precise Refrigerant Metering: Automatically adjusts flow to maintain optimal superheat, preventing evaporator coil icing or compressor liquid slugging.
- R410A Optimization: Specifically calibrated for R-410A systems to maximize thermal efficiency and cooling performance.
- OEM Compatibility: Genuine ICP (Heil Quaker) replacement ensures exact fitment for 2-ton residential and light commercial equipment.
- Complete Installation Kit: Includes sensing bulb thermal insulation and bulb clamps to ensure accurate temperature sensing on the suction line.
Common Questions
Is a hard start kit required when installing the 1192604 TXV?
While the 1192604 improves efficiency, the installation of a thermal expansion valve may necessitate a hard start kit (capacitor and relay) if the outdoor unit does not already have one, as the TXV does not bleed pressure during the off-cycle.
Can this kit be used on 1.5-ton or 2.5-ton systems?
No, this valve is fixed for 2-ton capacity. Using a mismatched TXV will lead to improper refrigerant flow, poor oil return, and potential system failure.
What is the correct mounting position for the sensing bulb?
On a horizontal vapor line, the sensing bulb should be mounted at the 10 o'clock or 2 o'clock position to ensure it reads the refrigerant temperature and not the oil traveling along the bottom of the pipe.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.