The Heil Quaker ICP 1191444 Integrated Furnace Control Board serves as a direct OEM replacement for malfunctioning ignition modules in high-efficiency gas furnaces. Engineered for ICP furnace repair, this dual-stage control board manages the critical sequence of operation, including the inducer motor, gas valve, and blower timings. As an HVAC circuit board replacement, the 1191444 ensures precise flame sensing and diagnostic feedback via onboard LED codes, reducing troubleshooting time on the job site. This 1191444 control module is designed to interface seamlessly with existing wiring harnesses, maintaining the structural integrity of the furnace's safety circuit. When dealing with Heil furnace parts, choosing this OEM board ensures exact voltage regulation and timing parameters required for late-model residential equipment. Integrating this electronic fan timer board restores reliable ignition cycles and optimizes airflow delivery across the heat exchanger, ensuring the system operates within manufacturer specifications.

Key Benefits for Contractors
  • Direct OEM Compatibility: Eliminates the need for field modifications or mounting bracket adjustments common with universal boards.
  • Advanced Diagnostics: Built-in fault code sequences provide rapid identification of pressure switch, limit, or flame sensor failures.
  • Optimized Timings: Pre-configured logic for heat/cool blower delays ensures maximum heat exchange efficiency and prevents short-cycling.
  • Heavy-Duty Relays: Robust switching components designed to handle the inductive loads of high-static blower motors.
Common Questions & Technical Support

Will this board fix a 'No Heat' call where the inducer runs but the igniter doesn't glow?
If the pressure switch has closed and the igniter is within ohm range, a failure in the ICP 1191444 relay logic is likely the culprit. Verify 120V output to the igniter before replacing.

Is this a direct replacement for older 1012-series boards?
The 1191444 board often replaces specific 1012 legacy models, but you must check the pin configuration on the terminal block to ensure the wiring harness matches the updated ICM-style footprint.

What does it mean if the LED is flashing a rapid code?
Rapid flashes typically indicate a reversed polarity or a ground fault. This board is sensitive to proper 24V phasing; ensure the transformer secondary is correctly grounded to the chassis.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$780.10
Heil Quaker ICP 1191444 Control Board
$780.10

Heil Quaker ICP 1191444 Control Board

The Heil Quaker ICP 1191444 Integrated Furnace Control Board serves as a direct OEM replacement for malfunctioning ignition modules in high-efficiency gas furnaces. Engineered for ICP furnace repair, this dual-stage control board manages the critical sequence of operation, including the inducer motor, gas valve, and blower timings. As an HVAC circuit board replacement, the 1191444 ensures precise flame sensing and diagnostic feedback via onboard LED codes, reducing troubleshooting time on the job site. This 1191444 control module is designed to interface seamlessly with existing wiring harnesses, maintaining the structural integrity of the furnace's safety circuit. When dealing with Heil furnace parts, choosing this OEM board ensures exact voltage regulation and timing parameters required for late-model residential equipment. Integrating this electronic fan timer board restores reliable ignition cycles and optimizes airflow delivery across the heat exchanger, ensuring the system operates within manufacturer specifications.

Key Benefits for Contractors
  • Direct OEM Compatibility: Eliminates the need for field modifications or mounting bracket adjustments common with universal boards.
  • Advanced Diagnostics: Built-in fault code sequences provide rapid identification of pressure switch, limit, or flame sensor failures.
  • Optimized Timings: Pre-configured logic for heat/cool blower delays ensures maximum heat exchange efficiency and prevents short-cycling.
  • Heavy-Duty Relays: Robust switching components designed to handle the inductive loads of high-static blower motors.
Common Questions & Technical Support

Will this board fix a 'No Heat' call where the inducer runs but the igniter doesn't glow?
If the pressure switch has closed and the igniter is within ohm range, a failure in the ICP 1191444 relay logic is likely the culprit. Verify 120V output to the igniter before replacing.

Is this a direct replacement for older 1012-series boards?
The 1191444 board often replaces specific 1012 legacy models, but you must check the pin configuration on the terminal block to ensure the wiring harness matches the updated ICM-style footprint.

What does it mean if the LED is flashing a rapid code?
Rapid flashes typically indicate a reversed polarity or a ground fault. This board is sensitive to proper 24V phasing; ensure the transformer secondary is correctly grounded to the chassis.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Heil Quaker ICP 1191444 Integrated Furnace Control Board serves as a direct OEM replacement for malfunctioning ignition modules in high-efficiency gas furnaces. Engineered for ICP furnace repair, this dual-stage control board manages the critical sequence of operation, including the inducer motor, gas valve, and blower timings. As an HVAC circuit board replacement, the 1191444 ensures precise flame sensing and diagnostic feedback via onboard LED codes, reducing troubleshooting time on the job site. This 1191444 control module is designed to interface seamlessly with existing wiring harnesses, maintaining the structural integrity of the furnace's safety circuit. When dealing with Heil furnace parts, choosing this OEM board ensures exact voltage regulation and timing parameters required for late-model residential equipment. Integrating this electronic fan timer board restores reliable ignition cycles and optimizes airflow delivery across the heat exchanger, ensuring the system operates within manufacturer specifications.

Key Benefits for Contractors
  • Direct OEM Compatibility: Eliminates the need for field modifications or mounting bracket adjustments common with universal boards.
  • Advanced Diagnostics: Built-in fault code sequences provide rapid identification of pressure switch, limit, or flame sensor failures.
  • Optimized Timings: Pre-configured logic for heat/cool blower delays ensures maximum heat exchange efficiency and prevents short-cycling.
  • Heavy-Duty Relays: Robust switching components designed to handle the inductive loads of high-static blower motors.
Common Questions & Technical Support

Will this board fix a 'No Heat' call where the inducer runs but the igniter doesn't glow?
If the pressure switch has closed and the igniter is within ohm range, a failure in the ICP 1191444 relay logic is likely the culprit. Verify 120V output to the igniter before replacing.

Is this a direct replacement for older 1012-series boards?
The 1191444 board often replaces specific 1012 legacy models, but you must check the pin configuration on the terminal block to ensure the wiring harness matches the updated ICM-style footprint.

What does it mean if the LED is flashing a rapid code?
Rapid flashes typically indicate a reversed polarity or a ground fault. This board is sensitive to proper 24V phasing; ensure the transformer secondary is correctly grounded to the chassis.