Heil Quaker ICP 1186074 Box Kit
HomeStore

Heil Quaker ICP 1186074 Box Kit

Heil Quaker ICP 1186074 Box Kit

When dealing with a cracked or leaking condensate collector box on 90%+ AFUE International Comfort Products (ICP) units, the Heil Quaker ICP 1186074 Box Kit is the verified solution for restoring secondary heat exchanger drainage and inducer performance. This OEM collector box kit serves as the direct replacement for 1184341 and is essential for preventing the vacuum loss and pressure switch faults (often manifesting as a Code 3) typically caused by hairline fractures or warped mating surfaces.

As a veteran tech, you know that brittle plastic and acidic condensate eventually compromise these components. This comprehensive ICP furnace repair kit includes the 1186074 collector box, replacement gaskets, and the necessary hardware to ensure a gastight seal between the secondary collector and the inducer housing. Swapping this part is a standard procedure to mitigate water accumulation in the combustion fan housing and avoid the premature failure of the inducer motor.

  • Direct OEM Compatibility: Verified ICP 1186074 replacement for discontinued part 1184341.
  • Enhanced Sealing: Includes high-quality collector box gaskets to prevent acidic condensate leaks that corrode furnace chassis.
  • Restores Vacuum Pressure: Eliminates air bypass to ensure the pressure switch closes reliably during the heating cycle.
  • Durable Construction: Engineered with heat-resistant polymers to withstand the thermal cycling adjacent to the heat exchanger.

Common Questions

Why is my ICP furnace throwing a pressure switch code when the inducer is running?
A cracked 1186074 collector box often causes a vacuum leak that prevents the pressure switch from sensing the necessary negative pressure. Inspect the box for hairline cracks, especially near the mounting points or where the condensate trap connects.

Do I need to apply additional RTV silicone when installing this kit?
While the kit includes official gaskets, many technicians prefer a thin bead of high-temperature RTV on the mating surface for extra insurance. Ensure the old gasket material is completely removed for a proper seal.

Will this kit work for all Heil, Tempstar, and Comfortmaker models?
The 1186074 kit fits a wide range of 95% efficiency units. Always verify your specific model number on the rating plate to ensure this kit matches your cabinet size and secondary heat exchanger configuration.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$80.74
Heil Quaker ICP 1186074 Box Kit
$80.74

Heil Quaker ICP 1186074 Box Kit

When dealing with a cracked or leaking condensate collector box on 90%+ AFUE International Comfort Products (ICP) units, the Heil Quaker ICP 1186074 Box Kit is the verified solution for restoring secondary heat exchanger drainage and inducer performance. This OEM collector box kit serves as the direct replacement for 1184341 and is essential for preventing the vacuum loss and pressure switch faults (often manifesting as a Code 3) typically caused by hairline fractures or warped mating surfaces.

As a veteran tech, you know that brittle plastic and acidic condensate eventually compromise these components. This comprehensive ICP furnace repair kit includes the 1186074 collector box, replacement gaskets, and the necessary hardware to ensure a gastight seal between the secondary collector and the inducer housing. Swapping this part is a standard procedure to mitigate water accumulation in the combustion fan housing and avoid the premature failure of the inducer motor.

  • Direct OEM Compatibility: Verified ICP 1186074 replacement for discontinued part 1184341.
  • Enhanced Sealing: Includes high-quality collector box gaskets to prevent acidic condensate leaks that corrode furnace chassis.
  • Restores Vacuum Pressure: Eliminates air bypass to ensure the pressure switch closes reliably during the heating cycle.
  • Durable Construction: Engineered with heat-resistant polymers to withstand the thermal cycling adjacent to the heat exchanger.

Common Questions

Why is my ICP furnace throwing a pressure switch code when the inducer is running?
A cracked 1186074 collector box often causes a vacuum leak that prevents the pressure switch from sensing the necessary negative pressure. Inspect the box for hairline cracks, especially near the mounting points or where the condensate trap connects.

Do I need to apply additional RTV silicone when installing this kit?
While the kit includes official gaskets, many technicians prefer a thin bead of high-temperature RTV on the mating surface for extra insurance. Ensure the old gasket material is completely removed for a proper seal.

Will this kit work for all Heil, Tempstar, and Comfortmaker models?
The 1186074 kit fits a wide range of 95% efficiency units. Always verify your specific model number on the rating plate to ensure this kit matches your cabinet size and secondary heat exchanger configuration.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

When dealing with a cracked or leaking condensate collector box on 90%+ AFUE International Comfort Products (ICP) units, the Heil Quaker ICP 1186074 Box Kit is the verified solution for restoring secondary heat exchanger drainage and inducer performance. This OEM collector box kit serves as the direct replacement for 1184341 and is essential for preventing the vacuum loss and pressure switch faults (often manifesting as a Code 3) typically caused by hairline fractures or warped mating surfaces.

As a veteran tech, you know that brittle plastic and acidic condensate eventually compromise these components. This comprehensive ICP furnace repair kit includes the 1186074 collector box, replacement gaskets, and the necessary hardware to ensure a gastight seal between the secondary collector and the inducer housing. Swapping this part is a standard procedure to mitigate water accumulation in the combustion fan housing and avoid the premature failure of the inducer motor.

  • Direct OEM Compatibility: Verified ICP 1186074 replacement for discontinued part 1184341.
  • Enhanced Sealing: Includes high-quality collector box gaskets to prevent acidic condensate leaks that corrode furnace chassis.
  • Restores Vacuum Pressure: Eliminates air bypass to ensure the pressure switch closes reliably during the heating cycle.
  • Durable Construction: Engineered with heat-resistant polymers to withstand the thermal cycling adjacent to the heat exchanger.

Common Questions

Why is my ICP furnace throwing a pressure switch code when the inducer is running?
A cracked 1186074 collector box often causes a vacuum leak that prevents the pressure switch from sensing the necessary negative pressure. Inspect the box for hairline cracks, especially near the mounting points or where the condensate trap connects.

Do I need to apply additional RTV silicone when installing this kit?
While the kit includes official gaskets, many technicians prefer a thin bead of high-temperature RTV on the mating surface for extra insurance. Ensure the old gasket material is completely removed for a proper seal.

Will this kit work for all Heil, Tempstar, and Comfortmaker models?
The 1186074 kit fits a wide range of 95% efficiency units. Always verify your specific model number on the rating plate to ensure this kit matches your cabinet size and secondary heat exchanger configuration.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.