Heil Quaker ICP 1174410 TXV
HomeStore

Heil Quaker ICP 1174410 TXV

Heil Quaker ICP 1174410 TXV

When you're dealing with a 4-ton system performance drop or hunting issues, the Heil Quaker ICP 1174410 TXV is the direct OEM replacement engineered for precise refrigerant metering. This thermal expansion valve is specifically designed for R410A refrigerant applications, providing the reliable superheat control necessary to protect the compressor and maintain evaporator efficiency. Rated for 4-ton capacity, this thermostatic expansion valve features a compact, durable construction that fits into standard ICP evaporator coils, ensuring a seamless fit for technicians in the field. By accurately adjusting flow based on heat load, it prevents liquid slugging and evaporator freeze-ups, restoring the HVAC system efficiency your customers expect from their air conditioner parts.

Key Benefits:

  • Precise Flow Control: Specifically calibrated for 4-ton R410A systems to maintain optimal superheat and prevent compressor damage.
  • OEM Compatibility: A genuine Heil Quaker ICP 1174410 part that ensures exact mechanical fit and functional alignment with original equipment.
  • Durable Construction: Built to withstand industrial-grade pressure and thermal cycling, reducing the need for premature TXV replacement.
  • Efficiency Optimization: Maximizes heat exchange at the evaporator, improving SEER performance and cooling consistency across varying ambient temperatures.

Common Questions:

How do I know if this TXV is failing?
Common indicators include the evaporator coil freezing up, the system "hunting" (rapidly fluctuating pressures), or "warm air from vents" despite the compressor running. A stuck-closed valve often results in high superheat and low suction pressure.

Is the sensing bulb location critical for this model?
Yes, for the ICP 1174410 to function correctly, the sensing bulb must be securely strapped to a horizontal section of the suction line at the 2 o'clock or 10 o'clock position and properly insulated to ensure accurate temperature readings.

Can I use this valve with R22 systems?
No. This valve is internally balanced and orifice-sized specifically for R410A refrigerant. Using it with R22 will lead to improper metering and potential system failure.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$120.18
Heil Quaker ICP 1174410 TXV
$120.18

Heil Quaker ICP 1174410 TXV

When you're dealing with a 4-ton system performance drop or hunting issues, the Heil Quaker ICP 1174410 TXV is the direct OEM replacement engineered for precise refrigerant metering. This thermal expansion valve is specifically designed for R410A refrigerant applications, providing the reliable superheat control necessary to protect the compressor and maintain evaporator efficiency. Rated for 4-ton capacity, this thermostatic expansion valve features a compact, durable construction that fits into standard ICP evaporator coils, ensuring a seamless fit for technicians in the field. By accurately adjusting flow based on heat load, it prevents liquid slugging and evaporator freeze-ups, restoring the HVAC system efficiency your customers expect from their air conditioner parts.

Key Benefits:

  • Precise Flow Control: Specifically calibrated for 4-ton R410A systems to maintain optimal superheat and prevent compressor damage.
  • OEM Compatibility: A genuine Heil Quaker ICP 1174410 part that ensures exact mechanical fit and functional alignment with original equipment.
  • Durable Construction: Built to withstand industrial-grade pressure and thermal cycling, reducing the need for premature TXV replacement.
  • Efficiency Optimization: Maximizes heat exchange at the evaporator, improving SEER performance and cooling consistency across varying ambient temperatures.

Common Questions:

How do I know if this TXV is failing?
Common indicators include the evaporator coil freezing up, the system "hunting" (rapidly fluctuating pressures), or "warm air from vents" despite the compressor running. A stuck-closed valve often results in high superheat and low suction pressure.

Is the sensing bulb location critical for this model?
Yes, for the ICP 1174410 to function correctly, the sensing bulb must be securely strapped to a horizontal section of the suction line at the 2 o'clock or 10 o'clock position and properly insulated to ensure accurate temperature readings.

Can I use this valve with R22 systems?
No. This valve is internally balanced and orifice-sized specifically for R410A refrigerant. Using it with R22 will lead to improper metering and potential system failure.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

When you're dealing with a 4-ton system performance drop or hunting issues, the Heil Quaker ICP 1174410 TXV is the direct OEM replacement engineered for precise refrigerant metering. This thermal expansion valve is specifically designed for R410A refrigerant applications, providing the reliable superheat control necessary to protect the compressor and maintain evaporator efficiency. Rated for 4-ton capacity, this thermostatic expansion valve features a compact, durable construction that fits into standard ICP evaporator coils, ensuring a seamless fit for technicians in the field. By accurately adjusting flow based on heat load, it prevents liquid slugging and evaporator freeze-ups, restoring the HVAC system efficiency your customers expect from their air conditioner parts.

Key Benefits:

  • Precise Flow Control: Specifically calibrated for 4-ton R410A systems to maintain optimal superheat and prevent compressor damage.
  • OEM Compatibility: A genuine Heil Quaker ICP 1174410 part that ensures exact mechanical fit and functional alignment with original equipment.
  • Durable Construction: Built to withstand industrial-grade pressure and thermal cycling, reducing the need for premature TXV replacement.
  • Efficiency Optimization: Maximizes heat exchange at the evaporator, improving SEER performance and cooling consistency across varying ambient temperatures.

Common Questions:

How do I know if this TXV is failing?
Common indicators include the evaporator coil freezing up, the system "hunting" (rapidly fluctuating pressures), or "warm air from vents" despite the compressor running. A stuck-closed valve often results in high superheat and low suction pressure.

Is the sensing bulb location critical for this model?
Yes, for the ICP 1174410 to function correctly, the sensing bulb must be securely strapped to a horizontal section of the suction line at the 2 o'clock or 10 o'clock position and properly insulated to ensure accurate temperature readings.

Can I use this valve with R22 systems?
No. This valve is internally balanced and orifice-sized specifically for R410A refrigerant. Using it with R22 will lead to improper metering and potential system failure.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Heil Quaker ICP 1174410 TXV | GSIstore