The Dwyer Instruments MSX-W12-IN-LCD is a highly adaptable differential pressure transmitter designed for professional building automation and HVACR control. Engineered to replace the MS2 series, this Magnesense transmitter features a wall mount configuration and a rotatable 180° LCD for precise monitoring in tight mechanical spaces. It supports unidirectional 0-5 in w.c. measurement with field-selectable ranges (1, 2, 3, or 5 in w.c.), ensuring compatibility with diverse duct static pressure and filter monitoring applications. This unit offers dual output functionality, providing simultaneous 4-20 mA current and 0-5/10 VDC voltage signals for seamless integration with high-end controllers. With ±1% FSO accuracy and a NEMA 4X rated enclosure, it delivers the stability required for VAV systems and clean room environments. The toolless terminal block simplifies the wiring process, while the square root extraction capability allows for direct air velocity and flow calculations, making it a versatile tool for any contractor's inventory.

Key Benefits for Technicians:
  • Field-Selectable Ranges: Configure between 1, 2, 3, and 5 in w.c. to match specific system requirements without stocking multiple units.
  • Dual Signal Output: Simultaneously provides 4-20 mA and 0-10V signals, allowing for both local control and remote monitoring verification.
  • Enhanced Safety: Built with UL94 V-0 and plenum-rated materials, suitable for installation in air handling plenums.
  • User-Friendly Interface: Features a digital push-button for zero and span adjustments, eliminating the need for potentiometers.
Common Questions:

Is the display readable if mounted upside down?
Yes, the 4-digit LCD display is rotatable by 180°, ensuring the process variable is always legible regardless of the housing orientation.

Can this unit calculate cfm or fpm?
The MSX-W12-IN-LCD includes a square root extraction function that enables the calculation of air velocity and volumetric flow when used with appropriate sensing probes.

What media is compatible with this sensor?
This transmitter is designed for use with air and non-combustible, non-corrosive compatible gases typically found in HVACR environments.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$66.24

Original: $189.27

-65%
Dwyer Instruments MSX-W12-IN-LCD Transmitter

$189.27

$66.24

Dwyer Instruments MSX-W12-IN-LCD Transmitter

The Dwyer Instruments MSX-W12-IN-LCD is a highly adaptable differential pressure transmitter designed for professional building automation and HVACR control. Engineered to replace the MS2 series, this Magnesense transmitter features a wall mount configuration and a rotatable 180° LCD for precise monitoring in tight mechanical spaces. It supports unidirectional 0-5 in w.c. measurement with field-selectable ranges (1, 2, 3, or 5 in w.c.), ensuring compatibility with diverse duct static pressure and filter monitoring applications. This unit offers dual output functionality, providing simultaneous 4-20 mA current and 0-5/10 VDC voltage signals for seamless integration with high-end controllers. With ±1% FSO accuracy and a NEMA 4X rated enclosure, it delivers the stability required for VAV systems and clean room environments. The toolless terminal block simplifies the wiring process, while the square root extraction capability allows for direct air velocity and flow calculations, making it a versatile tool for any contractor's inventory.

Key Benefits for Technicians:
  • Field-Selectable Ranges: Configure between 1, 2, 3, and 5 in w.c. to match specific system requirements without stocking multiple units.
  • Dual Signal Output: Simultaneously provides 4-20 mA and 0-10V signals, allowing for both local control and remote monitoring verification.
  • Enhanced Safety: Built with UL94 V-0 and plenum-rated materials, suitable for installation in air handling plenums.
  • User-Friendly Interface: Features a digital push-button for zero and span adjustments, eliminating the need for potentiometers.
Common Questions:

Is the display readable if mounted upside down?
Yes, the 4-digit LCD display is rotatable by 180°, ensuring the process variable is always legible regardless of the housing orientation.

Can this unit calculate cfm or fpm?
The MSX-W12-IN-LCD includes a square root extraction function that enables the calculation of air velocity and volumetric flow when used with appropriate sensing probes.

What media is compatible with this sensor?
This transmitter is designed for use with air and non-combustible, non-corrosive compatible gases typically found in HVACR environments.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Dwyer Instruments MSX-W12-IN-LCD is a highly adaptable differential pressure transmitter designed for professional building automation and HVACR control. Engineered to replace the MS2 series, this Magnesense transmitter features a wall mount configuration and a rotatable 180° LCD for precise monitoring in tight mechanical spaces. It supports unidirectional 0-5 in w.c. measurement with field-selectable ranges (1, 2, 3, or 5 in w.c.), ensuring compatibility with diverse duct static pressure and filter monitoring applications. This unit offers dual output functionality, providing simultaneous 4-20 mA current and 0-5/10 VDC voltage signals for seamless integration with high-end controllers. With ±1% FSO accuracy and a NEMA 4X rated enclosure, it delivers the stability required for VAV systems and clean room environments. The toolless terminal block simplifies the wiring process, while the square root extraction capability allows for direct air velocity and flow calculations, making it a versatile tool for any contractor's inventory.

Key Benefits for Technicians:
  • Field-Selectable Ranges: Configure between 1, 2, 3, and 5 in w.c. to match specific system requirements without stocking multiple units.
  • Dual Signal Output: Simultaneously provides 4-20 mA and 0-10V signals, allowing for both local control and remote monitoring verification.
  • Enhanced Safety: Built with UL94 V-0 and plenum-rated materials, suitable for installation in air handling plenums.
  • User-Friendly Interface: Features a digital push-button for zero and span adjustments, eliminating the need for potentiometers.
Common Questions:

Is the display readable if mounted upside down?
Yes, the 4-digit LCD display is rotatable by 180°, ensuring the process variable is always legible regardless of the housing orientation.

Can this unit calculate cfm or fpm?
The MSX-W12-IN-LCD includes a square root extraction function that enables the calculation of air velocity and volumetric flow when used with appropriate sensing probes.

What media is compatible with this sensor?
This transmitter is designed for use with air and non-combustible, non-corrosive compatible gases typically found in HVACR environments.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.