The Dwyer Instruments PAFS-1004 is a precision-engineered averaging flow sensor designed for heavy-duty HVAC and industrial air handling systems. This pitot tube air flow sensor features a 7 21/32" insertion length, making it ideal for accurate velocity measurements in smaller ductwork. Utilizing a multi-orifice design, the PAFS-1004 senses the total and static pressure to provide an average differential pressure signal, ensuring reliable duct airflow measurement even in non-uniform flow profiles. Constructed from durable 304 stainless steel, it is compatible with air and non-combustible gases. For seamless integration into existing pneumatic or electronic control loops, it utilizes a 1/4" I.D. and 3/8" OD tubing process connection. Field technicians value this series for its impact-resistant build and high-temperature tolerance, maintaining accuracy across a wide range of HVAC pressure sensing applications where traditional single-point sensors fail due to turbulence.

Key Benefits for the Contractor
  • Enhanced Accuracy: Multi-point sensing compensates for duct turbulence to provide a more stable differential pressure reading.
  • Rugged Construction: 304 Stainless steel probe ensures longevity in demanding commercial and industrial environments.
  • Simple Installation: Standard flange mounting and clear directional arrows allow for rapid field deployment.
  • Universal Compatibility: Works with most differential pressure transmitters and manometers for air velocity monitoring.
Common Technical Questions

How do I ensure the most accurate reading with the PAFS-1004?
Installation is critical; the sensor must be mounted with the sensing holes facing the airflow. For maximum stability, install the probe at least 8 to 10 duct diameters downstream from any elbows or transitions.

What is the maximum temperature rating for this averaging sensor?
The PAFS-1004 is designed for high-performance environments and can typically handle operating temperatures up to 400°F (204.4°C).

Can this be used with digital manometer systems?
Yes, the 1/4" I.D. tubing connection is standard for most HVAC airflow diagnostics tools and digital transmitters.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$7.04

Original: $20.10

-65%
Dwyer Instruments PAFS-1004 Sensor

$20.10

$7.04

Dwyer Instruments PAFS-1004 Sensor

The Dwyer Instruments PAFS-1004 is a precision-engineered averaging flow sensor designed for heavy-duty HVAC and industrial air handling systems. This pitot tube air flow sensor features a 7 21/32" insertion length, making it ideal for accurate velocity measurements in smaller ductwork. Utilizing a multi-orifice design, the PAFS-1004 senses the total and static pressure to provide an average differential pressure signal, ensuring reliable duct airflow measurement even in non-uniform flow profiles. Constructed from durable 304 stainless steel, it is compatible with air and non-combustible gases. For seamless integration into existing pneumatic or electronic control loops, it utilizes a 1/4" I.D. and 3/8" OD tubing process connection. Field technicians value this series for its impact-resistant build and high-temperature tolerance, maintaining accuracy across a wide range of HVAC pressure sensing applications where traditional single-point sensors fail due to turbulence.

Key Benefits for the Contractor
  • Enhanced Accuracy: Multi-point sensing compensates for duct turbulence to provide a more stable differential pressure reading.
  • Rugged Construction: 304 Stainless steel probe ensures longevity in demanding commercial and industrial environments.
  • Simple Installation: Standard flange mounting and clear directional arrows allow for rapid field deployment.
  • Universal Compatibility: Works with most differential pressure transmitters and manometers for air velocity monitoring.
Common Technical Questions

How do I ensure the most accurate reading with the PAFS-1004?
Installation is critical; the sensor must be mounted with the sensing holes facing the airflow. For maximum stability, install the probe at least 8 to 10 duct diameters downstream from any elbows or transitions.

What is the maximum temperature rating for this averaging sensor?
The PAFS-1004 is designed for high-performance environments and can typically handle operating temperatures up to 400°F (204.4°C).

Can this be used with digital manometer systems?
Yes, the 1/4" I.D. tubing connection is standard for most HVAC airflow diagnostics tools and digital transmitters.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Dwyer Instruments PAFS-1004 is a precision-engineered averaging flow sensor designed for heavy-duty HVAC and industrial air handling systems. This pitot tube air flow sensor features a 7 21/32" insertion length, making it ideal for accurate velocity measurements in smaller ductwork. Utilizing a multi-orifice design, the PAFS-1004 senses the total and static pressure to provide an average differential pressure signal, ensuring reliable duct airflow measurement even in non-uniform flow profiles. Constructed from durable 304 stainless steel, it is compatible with air and non-combustible gases. For seamless integration into existing pneumatic or electronic control loops, it utilizes a 1/4" I.D. and 3/8" OD tubing process connection. Field technicians value this series for its impact-resistant build and high-temperature tolerance, maintaining accuracy across a wide range of HVAC pressure sensing applications where traditional single-point sensors fail due to turbulence.

Key Benefits for the Contractor
  • Enhanced Accuracy: Multi-point sensing compensates for duct turbulence to provide a more stable differential pressure reading.
  • Rugged Construction: 304 Stainless steel probe ensures longevity in demanding commercial and industrial environments.
  • Simple Installation: Standard flange mounting and clear directional arrows allow for rapid field deployment.
  • Universal Compatibility: Works with most differential pressure transmitters and manometers for air velocity monitoring.
Common Technical Questions

How do I ensure the most accurate reading with the PAFS-1004?
Installation is critical; the sensor must be mounted with the sensing holes facing the airflow. For maximum stability, install the probe at least 8 to 10 duct diameters downstream from any elbows or transitions.

What is the maximum temperature rating for this averaging sensor?
The PAFS-1004 is designed for high-performance environments and can typically handle operating temperatures up to 400°F (204.4°C).

Can this be used with digital manometer systems?
Yes, the 1/4" I.D. tubing connection is standard for most HVAC airflow diagnostics tools and digital transmitters.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Dwyer Instruments PAFS-1004 Sensor | GSIstore