Dwyer Instruments 629C05-CH-P2-E5-S1 Pressure Transmitter
The Dwyer Instruments 629C-05-CH-P2-E5-S1 is a professional-grade wet/wet differential pressure transmitter designed for precise monitoring of compatible liquids and gases in demanding HVACR applications. This model features a 0 to 100 psid range and utilizes dual 316L stainless steel sensors to convert pressure changes into a stable 4 to 20 mA output. The NEMA 4X conduit housing provides a rugged, IP66-rated enclosure that facilitates field wiring through a 1/2" female NPT electrical connection. For process integration, the unit is equipped with 1/4" female NPT fittings, ensuring reliable compatibility with standard manifold setups and piping. A compensated temperature range of 0 to 175°F and an accuracy of ±0.5% FS make this differential pressure sensor a staple for monitoring chillers, heat exchangers, and pump performance. The internal terminal block and push-button zero/span adjustments allow for streamlined calibration and maintenance without specialized tools.
Key Benefits:- High-Accuracy Performance: Delivers ±0.5% full-scale accuracy, including linearity, hysteresis, and repeatability for critical system monitoring.
- Corrosion-Resistant Components: Wetted materials consist of 316 and 316L stainless steel, making it suitable for a wide variety of industrial fluids and gases.
- Rugged Environmental Protection: The NEMA 4X (IP66) housing ensures long-term reliability in wash-down environments or outdoor installations.
- Simplified Field Maintenance: Features a removable terminal block and accessible push-button zeroing to reduce technician bench time.
- Can this transmitter be used with both liquids and gases? Yes, the wet/wet DP transmitter design is compatible with both compatible gases and liquids across both pressure ports.
- What is the maximum overpressure for the 100 psid model? The 629C-05 series has a working pressure limit of 200 psi and an overpressure rating of 500 psi.
- Does this model support 3-wire voltage output? This specific configuration is a 2-wire 4 to 20 mA loop-powered device, though other 629C models offer field-selectable voltage.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $541.62
-65%$541.62
$189.57Dwyer Instruments 629C05-CH-P2-E5-S1 Pressure Transmitter
The Dwyer Instruments 629C-05-CH-P2-E5-S1 is a professional-grade wet/wet differential pressure transmitter designed for precise monitoring of compatible liquids and gases in demanding HVACR applications. This model features a 0 to 100 psid range and utilizes dual 316L stainless steel sensors to convert pressure changes into a stable 4 to 20 mA output. The NEMA 4X conduit housing provides a rugged, IP66-rated enclosure that facilitates field wiring through a 1/2" female NPT electrical connection. For process integration, the unit is equipped with 1/4" female NPT fittings, ensuring reliable compatibility with standard manifold setups and piping. A compensated temperature range of 0 to 175°F and an accuracy of ±0.5% FS make this differential pressure sensor a staple for monitoring chillers, heat exchangers, and pump performance. The internal terminal block and push-button zero/span adjustments allow for streamlined calibration and maintenance without specialized tools.
Key Benefits:- High-Accuracy Performance: Delivers ±0.5% full-scale accuracy, including linearity, hysteresis, and repeatability for critical system monitoring.
- Corrosion-Resistant Components: Wetted materials consist of 316 and 316L stainless steel, making it suitable for a wide variety of industrial fluids and gases.
- Rugged Environmental Protection: The NEMA 4X (IP66) housing ensures long-term reliability in wash-down environments or outdoor installations.
- Simplified Field Maintenance: Features a removable terminal block and accessible push-button zeroing to reduce technician bench time.
- Can this transmitter be used with both liquids and gases? Yes, the wet/wet DP transmitter design is compatible with both compatible gases and liquids across both pressure ports.
- What is the maximum overpressure for the 100 psid model? The 629C-05 series has a working pressure limit of 200 psi and an overpressure rating of 500 psi.
- Does this model support 3-wire voltage output? This specific configuration is a 2-wire 4 to 20 mA loop-powered device, though other 629C models offer field-selectable voltage.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Dwyer Instruments 629C-05-CH-P2-E5-S1 is a professional-grade wet/wet differential pressure transmitter designed for precise monitoring of compatible liquids and gases in demanding HVACR applications. This model features a 0 to 100 psid range and utilizes dual 316L stainless steel sensors to convert pressure changes into a stable 4 to 20 mA output. The NEMA 4X conduit housing provides a rugged, IP66-rated enclosure that facilitates field wiring through a 1/2" female NPT electrical connection. For process integration, the unit is equipped with 1/4" female NPT fittings, ensuring reliable compatibility with standard manifold setups and piping. A compensated temperature range of 0 to 175°F and an accuracy of ±0.5% FS make this differential pressure sensor a staple for monitoring chillers, heat exchangers, and pump performance. The internal terminal block and push-button zero/span adjustments allow for streamlined calibration and maintenance without specialized tools.
Key Benefits:- High-Accuracy Performance: Delivers ±0.5% full-scale accuracy, including linearity, hysteresis, and repeatability for critical system monitoring.
- Corrosion-Resistant Components: Wetted materials consist of 316 and 316L stainless steel, making it suitable for a wide variety of industrial fluids and gases.
- Rugged Environmental Protection: The NEMA 4X (IP66) housing ensures long-term reliability in wash-down environments or outdoor installations.
- Simplified Field Maintenance: Features a removable terminal block and accessible push-button zeroing to reduce technician bench time.
- Can this transmitter be used with both liquids and gases? Yes, the wet/wet DP transmitter design is compatible with both compatible gases and liquids across both pressure ports.
- What is the maximum overpressure for the 100 psid model? The 629C-05 series has a working pressure limit of 200 psi and an overpressure rating of 500 psi.
- Does this model support 3-wire voltage output? This specific configuration is a 2-wire 4 to 20 mA loop-powered device, though other 629C models offer field-selectable voltage.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.