Dwyer Instruments 629C04CHP2E5S1 Pressure Transmitter
HomeStore

Dwyer Instruments 629C04CHP2E5S1 Pressure Transmitter

Dwyer Instruments 629C04CHP2E5S1 Pressure Transmitter

The Dwyer Instruments 629C-04-CH-P2-E5-S1 is a robust wet/wet differential pressure transmitter engineered for demanding HVACR and industrial applications. This unit features a 0 to 50 psid range with a high-accuracy 0.5% FS rating, ensuring precise monitoring of liquid and gas pressures across chillers, heat exchangers, and pumping systems. Built with a rugged NEMA 4X conduit housing, the 629C series is designed to withstand harsh environments while protecting internal electronics from moisture and corrosion. The 4-20 mA output signal provides reliable data transmission over long cable runs, a standard requirement for integration with building automation systems and PLCs. For field installation, this model utilizes 1/4" female NPT process connections and a 1/2" female NPT conduit electrical connection. Its dual pressure sensors allow for high overpressure ratings and excellent stability, making it a dependable choice for monitoring differential pressure across filters and cooling coils.

Key Benefits for Contractors
  • Corrosion Resistance: 316L stainless steel wetted parts ensure compatibility with a wide range of compatible gases and liquids.
  • Rugged Enclosure: The NEMA 4X (IP66) housing allows for installation in wash-down areas or outdoor environments without additional shielding.
  • Fast Response Time: Optimized for real-time system feedback, reducing lag in variable frequency drive (VFD) control loops.
  • Standardized Integration: The 4-20 mA loop-powered configuration simplifies wiring protocols for field technicians.
Common Questions for 629C-04-CH-P2-E5-S1

What is the maximum overpressure for this 50 psid model?
This transmitter typically supports a maximum pressure of 160 psi on either port, preventing damage during sudden system surges or pump cycling.

Can this be used for both liquid and gas applications?
Yes, the wet/wet differential pressure sensor design is compatible with both liquids and gases that are compatible with the 316L stainless steel sensing elements.

How do I handle zero-point calibration in the field?
The 629C series includes accessible zero and span adjustments inside the housing, allowing for precise field tuning to account for elevation or installation offsets.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$175.38

Original: $501.08

-65%
Dwyer Instruments 629C04CHP2E5S1 Pressure Transmitter

$501.08

$175.38

Dwyer Instruments 629C04CHP2E5S1 Pressure Transmitter

The Dwyer Instruments 629C-04-CH-P2-E5-S1 is a robust wet/wet differential pressure transmitter engineered for demanding HVACR and industrial applications. This unit features a 0 to 50 psid range with a high-accuracy 0.5% FS rating, ensuring precise monitoring of liquid and gas pressures across chillers, heat exchangers, and pumping systems. Built with a rugged NEMA 4X conduit housing, the 629C series is designed to withstand harsh environments while protecting internal electronics from moisture and corrosion. The 4-20 mA output signal provides reliable data transmission over long cable runs, a standard requirement for integration with building automation systems and PLCs. For field installation, this model utilizes 1/4" female NPT process connections and a 1/2" female NPT conduit electrical connection. Its dual pressure sensors allow for high overpressure ratings and excellent stability, making it a dependable choice for monitoring differential pressure across filters and cooling coils.

Key Benefits for Contractors
  • Corrosion Resistance: 316L stainless steel wetted parts ensure compatibility with a wide range of compatible gases and liquids.
  • Rugged Enclosure: The NEMA 4X (IP66) housing allows for installation in wash-down areas or outdoor environments without additional shielding.
  • Fast Response Time: Optimized for real-time system feedback, reducing lag in variable frequency drive (VFD) control loops.
  • Standardized Integration: The 4-20 mA loop-powered configuration simplifies wiring protocols for field technicians.
Common Questions for 629C-04-CH-P2-E5-S1

What is the maximum overpressure for this 50 psid model?
This transmitter typically supports a maximum pressure of 160 psi on either port, preventing damage during sudden system surges or pump cycling.

Can this be used for both liquid and gas applications?
Yes, the wet/wet differential pressure sensor design is compatible with both liquids and gases that are compatible with the 316L stainless steel sensing elements.

How do I handle zero-point calibration in the field?
The 629C series includes accessible zero and span adjustments inside the housing, allowing for precise field tuning to account for elevation or installation offsets.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Dwyer Instruments 629C-04-CH-P2-E5-S1 is a robust wet/wet differential pressure transmitter engineered for demanding HVACR and industrial applications. This unit features a 0 to 50 psid range with a high-accuracy 0.5% FS rating, ensuring precise monitoring of liquid and gas pressures across chillers, heat exchangers, and pumping systems. Built with a rugged NEMA 4X conduit housing, the 629C series is designed to withstand harsh environments while protecting internal electronics from moisture and corrosion. The 4-20 mA output signal provides reliable data transmission over long cable runs, a standard requirement for integration with building automation systems and PLCs. For field installation, this model utilizes 1/4" female NPT process connections and a 1/2" female NPT conduit electrical connection. Its dual pressure sensors allow for high overpressure ratings and excellent stability, making it a dependable choice for monitoring differential pressure across filters and cooling coils.

Key Benefits for Contractors
  • Corrosion Resistance: 316L stainless steel wetted parts ensure compatibility with a wide range of compatible gases and liquids.
  • Rugged Enclosure: The NEMA 4X (IP66) housing allows for installation in wash-down areas or outdoor environments without additional shielding.
  • Fast Response Time: Optimized for real-time system feedback, reducing lag in variable frequency drive (VFD) control loops.
  • Standardized Integration: The 4-20 mA loop-powered configuration simplifies wiring protocols for field technicians.
Common Questions for 629C-04-CH-P2-E5-S1

What is the maximum overpressure for this 50 psid model?
This transmitter typically supports a maximum pressure of 160 psi on either port, preventing damage during sudden system surges or pump cycling.

Can this be used for both liquid and gas applications?
Yes, the wet/wet differential pressure sensor design is compatible with both liquids and gases that are compatible with the 316L stainless steel sensing elements.

How do I handle zero-point calibration in the field?
The 629C series includes accessible zero and span adjustments inside the housing, allowing for precise field tuning to account for elevation or installation offsets.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Dwyer Instruments 629C04CHP2E5S1 Pressure Transmitter | GSIstore