York S1-151492 Expansion Valve
HomeStore

York S1-151492 Expansion Valve

York S1-151492 Expansion Valve

Maintain peak evaporator efficiency with the York S1-151492 Thermal Expansion Valve, an essential OEM component for precise refrigerant metering. This 1/2 x 1/2 ODF TXV is engineered to balance the cooling load by monitoring superheat, preventing the risk of liquid floodback to the compressor. Featuring a 30-inch sensing bulb capillary, the S1-151492 expansion valve provides responsive control across a wide range of operating conditions, making it a reliable choice for commercial and residential split systems, heat pumps, and chillers. The ODF solder connections ensure a leak-resistant, permanent seal within the copper liquid line. For technicians performing system restoration or routine maintenance, utilizing this genuine York HVAC part guarantees compatibility with original equipment specifications, ensuring the system maintains its designed SEER ratings and thermal performance without the diagnostic headaches associated with universal alternatives.

Key Benefits for Technicians
  • Precise Superheat Regulation: Maximizes coil surface utilization while protecting the compressor from slugging.
  • OEM Compatibility: Exact replacement for York and Johnson Controls equipment, eliminating the need for field modifications.
  • Durable Construction: Built with high-grade materials to withstand the high-cycle demands of industrial and process cooling applications.
  • Extended Capillary Reach: The 30" lead allows for flexible sensing bulb placement on suction lines for accurate temperature feedback.
  • ODF Connections: Standard 1/2" x 1/2" solder ports facilitate a clean, professional installation in tight service panels.
Common Questions

Is the York S1-151492 compatible with R-410A systems?
Yes, this thermal expansion valve is designed for high-pressure refrigerants common in modern York air conditioning and heat pump units. Always verify the specific refrigerant requirements on the equipment data plate before installation.

What is the primary function of the 30-inch lead on this TXV?
The 30" capillary tube connects the valve body to the sensing bulb. This length provides technicians with sufficient slack to properly insulate and secure the bulb to the suction line, ensuring the valve reacts accurately to evaporator exit temperatures.

Can this valve be used in both cooling and heating cycles?
The S1-151492 is commonly utilized in heat pump applications where bi-flow or specific metering characteristics are required. Its robust internal design handles the pressure fluctuations typical of reversible cycles.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$614.82
York S1-151492 Expansion Valve
$614.82

York S1-151492 Expansion Valve

Maintain peak evaporator efficiency with the York S1-151492 Thermal Expansion Valve, an essential OEM component for precise refrigerant metering. This 1/2 x 1/2 ODF TXV is engineered to balance the cooling load by monitoring superheat, preventing the risk of liquid floodback to the compressor. Featuring a 30-inch sensing bulb capillary, the S1-151492 expansion valve provides responsive control across a wide range of operating conditions, making it a reliable choice for commercial and residential split systems, heat pumps, and chillers. The ODF solder connections ensure a leak-resistant, permanent seal within the copper liquid line. For technicians performing system restoration or routine maintenance, utilizing this genuine York HVAC part guarantees compatibility with original equipment specifications, ensuring the system maintains its designed SEER ratings and thermal performance without the diagnostic headaches associated with universal alternatives.

Key Benefits for Technicians
  • Precise Superheat Regulation: Maximizes coil surface utilization while protecting the compressor from slugging.
  • OEM Compatibility: Exact replacement for York and Johnson Controls equipment, eliminating the need for field modifications.
  • Durable Construction: Built with high-grade materials to withstand the high-cycle demands of industrial and process cooling applications.
  • Extended Capillary Reach: The 30" lead allows for flexible sensing bulb placement on suction lines for accurate temperature feedback.
  • ODF Connections: Standard 1/2" x 1/2" solder ports facilitate a clean, professional installation in tight service panels.
Common Questions

Is the York S1-151492 compatible with R-410A systems?
Yes, this thermal expansion valve is designed for high-pressure refrigerants common in modern York air conditioning and heat pump units. Always verify the specific refrigerant requirements on the equipment data plate before installation.

What is the primary function of the 30-inch lead on this TXV?
The 30" capillary tube connects the valve body to the sensing bulb. This length provides technicians with sufficient slack to properly insulate and secure the bulb to the suction line, ensuring the valve reacts accurately to evaporator exit temperatures.

Can this valve be used in both cooling and heating cycles?
The S1-151492 is commonly utilized in heat pump applications where bi-flow or specific metering characteristics are required. Its robust internal design handles the pressure fluctuations typical of reversible cycles.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

Maintain peak evaporator efficiency with the York S1-151492 Thermal Expansion Valve, an essential OEM component for precise refrigerant metering. This 1/2 x 1/2 ODF TXV is engineered to balance the cooling load by monitoring superheat, preventing the risk of liquid floodback to the compressor. Featuring a 30-inch sensing bulb capillary, the S1-151492 expansion valve provides responsive control across a wide range of operating conditions, making it a reliable choice for commercial and residential split systems, heat pumps, and chillers. The ODF solder connections ensure a leak-resistant, permanent seal within the copper liquid line. For technicians performing system restoration or routine maintenance, utilizing this genuine York HVAC part guarantees compatibility with original equipment specifications, ensuring the system maintains its designed SEER ratings and thermal performance without the diagnostic headaches associated with universal alternatives.

Key Benefits for Technicians
  • Precise Superheat Regulation: Maximizes coil surface utilization while protecting the compressor from slugging.
  • OEM Compatibility: Exact replacement for York and Johnson Controls equipment, eliminating the need for field modifications.
  • Durable Construction: Built with high-grade materials to withstand the high-cycle demands of industrial and process cooling applications.
  • Extended Capillary Reach: The 30" lead allows for flexible sensing bulb placement on suction lines for accurate temperature feedback.
  • ODF Connections: Standard 1/2" x 1/2" solder ports facilitate a clean, professional installation in tight service panels.
Common Questions

Is the York S1-151492 compatible with R-410A systems?
Yes, this thermal expansion valve is designed for high-pressure refrigerants common in modern York air conditioning and heat pump units. Always verify the specific refrigerant requirements on the equipment data plate before installation.

What is the primary function of the 30-inch lead on this TXV?
The 30" capillary tube connects the valve body to the sensing bulb. This length provides technicians with sufficient slack to properly insulate and secure the bulb to the suction line, ensuring the valve reacts accurately to evaporator exit temperatures.

Can this valve be used in both cooling and heating cycles?
The S1-151492 is commonly utilized in heat pump applications where bi-flow or specific metering characteristics are required. Its robust internal design handles the pressure fluctuations typical of reversible cycles.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.