York S1-024-39562-000 Switch
HomeStore

York S1-024-39562-000 Switch

York S1-024-39562-000 Switch

As a field tech, you know that a flickering inducer or a lockout code usually points straight to the pressure switch. The York S1-024-39562-000 Switch is a critical safety component designed for high-pressure monitoring in refrigeration systems and HVAC condensing units. This OEM part features a factory-calibrated 650/450 PSI setpoint, acting as a reliable high-limit cutout to protect compressors from catastrophic head pressure spikes.

Built with a zinc housing and copper electrical connections, this switch is engineered to withstand the vibration and thermal cycling common in York, Coleman, and Luxaire equipment. Whether you are dealing with a blocked condenser coil or a failing fan motor, this normally closed switch ensures the system cuts power before internal safeties are breached. Its compact 0.5-inch (14mm) fitting allows for quick installation in tight service ports, keeping downtime to a minimum for your customers. For contractors maintaining R-410A systems, having this specific 650 PSI cutout on the truck is essential for ensuring localized high-side protection.

Key Benefits for the Technician
  • Precise 650/450 PSI Calibration: Provides accurate high-pressure cutout at 650 PSI with a consistent reset at 450 PSI.
  • OEM Compatibility: Exact replacement for Source 1 and York part number S1-024-39562-000, ensuring zero-clearance mounting.
  • Durable Construction: Heavy-duty zinc casing and copper terminals resist corrosion in outdoor environments.
  • Enhanced Equipment Protection: Prevents compressor damage by monitoring high-side refrigerant pressure and initiating immediate system shutdown when necessary.
Common Questions from the Field

What causes a high-pressure switch to trip frequently?
In most cases, a high-pressure cutout is triggered by poor airflow across the condenser coil, a failed condenser fan motor, or an overcharged system. Always check for debris or non-condensables before assuming the switch is faulty.

Can I use this switch for low-pressure applications?
No. This is specifically a high-pressure switch designed with a 650 PSI trip point. For low-pressure suction monitoring, you must use a switch with a much lower rating (typically 35-50 PSI) to prevent evaporator coil freezing.

Is this switch manually reset or automatic?
This model is an automatic reset pressure switch, meaning it will re-close the circuit once the system pressure drops back down to 450 PSI.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$28.76

Original: $82.16

-65%
York S1-024-39562-000 Switch

$82.16

$28.76

York S1-024-39562-000 Switch

As a field tech, you know that a flickering inducer or a lockout code usually points straight to the pressure switch. The York S1-024-39562-000 Switch is a critical safety component designed for high-pressure monitoring in refrigeration systems and HVAC condensing units. This OEM part features a factory-calibrated 650/450 PSI setpoint, acting as a reliable high-limit cutout to protect compressors from catastrophic head pressure spikes.

Built with a zinc housing and copper electrical connections, this switch is engineered to withstand the vibration and thermal cycling common in York, Coleman, and Luxaire equipment. Whether you are dealing with a blocked condenser coil or a failing fan motor, this normally closed switch ensures the system cuts power before internal safeties are breached. Its compact 0.5-inch (14mm) fitting allows for quick installation in tight service ports, keeping downtime to a minimum for your customers. For contractors maintaining R-410A systems, having this specific 650 PSI cutout on the truck is essential for ensuring localized high-side protection.

Key Benefits for the Technician
  • Precise 650/450 PSI Calibration: Provides accurate high-pressure cutout at 650 PSI with a consistent reset at 450 PSI.
  • OEM Compatibility: Exact replacement for Source 1 and York part number S1-024-39562-000, ensuring zero-clearance mounting.
  • Durable Construction: Heavy-duty zinc casing and copper terminals resist corrosion in outdoor environments.
  • Enhanced Equipment Protection: Prevents compressor damage by monitoring high-side refrigerant pressure and initiating immediate system shutdown when necessary.
Common Questions from the Field

What causes a high-pressure switch to trip frequently?
In most cases, a high-pressure cutout is triggered by poor airflow across the condenser coil, a failed condenser fan motor, or an overcharged system. Always check for debris or non-condensables before assuming the switch is faulty.

Can I use this switch for low-pressure applications?
No. This is specifically a high-pressure switch designed with a 650 PSI trip point. For low-pressure suction monitoring, you must use a switch with a much lower rating (typically 35-50 PSI) to prevent evaporator coil freezing.

Is this switch manually reset or automatic?
This model is an automatic reset pressure switch, meaning it will re-close the circuit once the system pressure drops back down to 450 PSI.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

As a field tech, you know that a flickering inducer or a lockout code usually points straight to the pressure switch. The York S1-024-39562-000 Switch is a critical safety component designed for high-pressure monitoring in refrigeration systems and HVAC condensing units. This OEM part features a factory-calibrated 650/450 PSI setpoint, acting as a reliable high-limit cutout to protect compressors from catastrophic head pressure spikes.

Built with a zinc housing and copper electrical connections, this switch is engineered to withstand the vibration and thermal cycling common in York, Coleman, and Luxaire equipment. Whether you are dealing with a blocked condenser coil or a failing fan motor, this normally closed switch ensures the system cuts power before internal safeties are breached. Its compact 0.5-inch (14mm) fitting allows for quick installation in tight service ports, keeping downtime to a minimum for your customers. For contractors maintaining R-410A systems, having this specific 650 PSI cutout on the truck is essential for ensuring localized high-side protection.

Key Benefits for the Technician
  • Precise 650/450 PSI Calibration: Provides accurate high-pressure cutout at 650 PSI with a consistent reset at 450 PSI.
  • OEM Compatibility: Exact replacement for Source 1 and York part number S1-024-39562-000, ensuring zero-clearance mounting.
  • Durable Construction: Heavy-duty zinc casing and copper terminals resist corrosion in outdoor environments.
  • Enhanced Equipment Protection: Prevents compressor damage by monitoring high-side refrigerant pressure and initiating immediate system shutdown when necessary.
Common Questions from the Field

What causes a high-pressure switch to trip frequently?
In most cases, a high-pressure cutout is triggered by poor airflow across the condenser coil, a failed condenser fan motor, or an overcharged system. Always check for debris or non-condensables before assuming the switch is faulty.

Can I use this switch for low-pressure applications?
No. This is specifically a high-pressure switch designed with a 650 PSI trip point. For low-pressure suction monitoring, you must use a switch with a much lower rating (typically 35-50 PSI) to prevent evaporator coil freezing.

Is this switch manually reset or automatic?
This model is an automatic reset pressure switch, meaning it will re-close the circuit once the system pressure drops back down to 450 PSI.