York S1-024-36024-000 Relay
The York S1-024-36024-000 Heat Sequencer Relay is a critical electrical component engineered for staging multi-element heating kits in residential and light commercial HVAC systems. This OEM York sequencer manages the activation and deactivation of electric heat strips, specifically designed for compatibility with the York 6HK series electric heaters and various split-system air handlers. By utilizing a bimetal switch and heater coil, it staggers the electrical load across the circuit, preventing line voltage drops and nuisance circuit breaker trips during cold-start transitions.
For service technicians, this 24V heat sequencer is the standard solution for troubleshooting furnace blower delays and unresponsive heating stages. Its robust construction handles the thermal cycling typical of heat pump auxiliary heating and emergency heat modes. Replacing a failed relay with this genuine HVAC sequencer replacement ensures the precise timing of terminal contacts, maintaining the staging logic required for efficient airflow and element longevity. When diagnosing "no heat" calls where the blower engages but elements remain cold, verifying the 24V signal to the sequencer base is the primary step before swapping this sequencer control relay.
Key Benefits- Staged Activation: Prevents massive current draws by bringing heating elements online in timed intervals.
- OEM Compatibility: Drop-in replacement for York 6HK series electric heat kits, ensuring correct terminal alignment and mounting.
- Circuit Protection: Eliminates micro-switching issues and reduces wear on the primary contactor and blower relay.
- System Efficiency: Manages heat-on and heat-off delays to maximize heat transfer across the evap coil before the blower shuts down.
What are the signs of a failing York S1-024-36024-000 relay?
Technicians often see "stuck" contacts where heating elements stay energized after the thermostat is satisfied, or "open" failures where the 24V coil heats up but the internal bimetal fails to close the high-voltage circuit.
Can I use this relay for both the blower and the heat strips?
Yes, this sequencer is typically wired to trigger the furnace blower and the first stage of electric heat simultaneously to ensure the heat exchanger does not overheat.
Is this part compatible with other air handler brands?
While designed for York, Luxaire, and Coleman 6HK kits, it can replace other sequencers with equivalent timing specifications and terminal counts; however, checking the wiring diagram is essential for cross-brand applications.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $158.86
-65%$158.86
$55.60York S1-024-36024-000 Relay
The York S1-024-36024-000 Heat Sequencer Relay is a critical electrical component engineered for staging multi-element heating kits in residential and light commercial HVAC systems. This OEM York sequencer manages the activation and deactivation of electric heat strips, specifically designed for compatibility with the York 6HK series electric heaters and various split-system air handlers. By utilizing a bimetal switch and heater coil, it staggers the electrical load across the circuit, preventing line voltage drops and nuisance circuit breaker trips during cold-start transitions.
For service technicians, this 24V heat sequencer is the standard solution for troubleshooting furnace blower delays and unresponsive heating stages. Its robust construction handles the thermal cycling typical of heat pump auxiliary heating and emergency heat modes. Replacing a failed relay with this genuine HVAC sequencer replacement ensures the precise timing of terminal contacts, maintaining the staging logic required for efficient airflow and element longevity. When diagnosing "no heat" calls where the blower engages but elements remain cold, verifying the 24V signal to the sequencer base is the primary step before swapping this sequencer control relay.
Key Benefits- Staged Activation: Prevents massive current draws by bringing heating elements online in timed intervals.
- OEM Compatibility: Drop-in replacement for York 6HK series electric heat kits, ensuring correct terminal alignment and mounting.
- Circuit Protection: Eliminates micro-switching issues and reduces wear on the primary contactor and blower relay.
- System Efficiency: Manages heat-on and heat-off delays to maximize heat transfer across the evap coil before the blower shuts down.
What are the signs of a failing York S1-024-36024-000 relay?
Technicians often see "stuck" contacts where heating elements stay energized after the thermostat is satisfied, or "open" failures where the 24V coil heats up but the internal bimetal fails to close the high-voltage circuit.
Can I use this relay for both the blower and the heat strips?
Yes, this sequencer is typically wired to trigger the furnace blower and the first stage of electric heat simultaneously to ensure the heat exchanger does not overheat.
Is this part compatible with other air handler brands?
While designed for York, Luxaire, and Coleman 6HK kits, it can replace other sequencers with equivalent timing specifications and terminal counts; however, checking the wiring diagram is essential for cross-brand applications.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The York S1-024-36024-000 Heat Sequencer Relay is a critical electrical component engineered for staging multi-element heating kits in residential and light commercial HVAC systems. This OEM York sequencer manages the activation and deactivation of electric heat strips, specifically designed for compatibility with the York 6HK series electric heaters and various split-system air handlers. By utilizing a bimetal switch and heater coil, it staggers the electrical load across the circuit, preventing line voltage drops and nuisance circuit breaker trips during cold-start transitions.
For service technicians, this 24V heat sequencer is the standard solution for troubleshooting furnace blower delays and unresponsive heating stages. Its robust construction handles the thermal cycling typical of heat pump auxiliary heating and emergency heat modes. Replacing a failed relay with this genuine HVAC sequencer replacement ensures the precise timing of terminal contacts, maintaining the staging logic required for efficient airflow and element longevity. When diagnosing "no heat" calls where the blower engages but elements remain cold, verifying the 24V signal to the sequencer base is the primary step before swapping this sequencer control relay.
Key Benefits- Staged Activation: Prevents massive current draws by bringing heating elements online in timed intervals.
- OEM Compatibility: Drop-in replacement for York 6HK series electric heat kits, ensuring correct terminal alignment and mounting.
- Circuit Protection: Eliminates micro-switching issues and reduces wear on the primary contactor and blower relay.
- System Efficiency: Manages heat-on and heat-off delays to maximize heat transfer across the evap coil before the blower shuts down.
What are the signs of a failing York S1-024-36024-000 relay?
Technicians often see "stuck" contacts where heating elements stay energized after the thermostat is satisfied, or "open" failures where the 24V coil heats up but the internal bimetal fails to close the high-voltage circuit.
Can I use this relay for both the blower and the heat strips?
Yes, this sequencer is typically wired to trigger the furnace blower and the first stage of electric heat simultaneously to ensure the heat exchanger does not overheat.
Is this part compatible with other air handler brands?
While designed for York, Luxaire, and Coleman 6HK kits, it can replace other sequencers with equivalent timing specifications and terminal counts; however, checking the wiring diagram is essential for cross-brand applications.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.