The Utica-Dunkirk 240009241 Control Board is a specialized integrated boiler control (IBC) designed to manage ignition sequences, temperature monitoring, and safety protocols for high-efficiency hydronic systems. This direct replacement OEM control board is engineered to restore the logic for gas-fired hot water boilers, ensuring precise modulation and sequence control for units including the Utica MGB and Dunkirk DGB series. It features high-durability relays and logic sensors capable of handling the precise electrical loads required by domestic heating applications. For a boiler replacement part of this caliber, field testing confirms its ability to handle cyclic stress while maintaining the integrity of the safety limit circuit. This furnace control circuit board streamlines the diagnostic process with clear LED indicator signals, allowing technicians to verify flame rectification and thermostat calls rapidly. Replacing an outdated or faulty 1012-83-9241A model with this verified 240009241 ensures proper communication between the gas valve, high-limit switch, and the primary circulator pump.

Key Technical Benefits
  • Direct OEM Compatibility: Verified fit for specific Utica and Dunkirk boiler models, reducing field modification time.
  • Reliable Ignition Sequencing: Provides consistent flame sensing and spark ignition control to ensure safe startup cycles.
  • Enhanced Diagnostics: Integrated status indicators assist with HVAC troubleshooting of the safety loop and power delivery.
  • Thermal Management: Engineered to withstand the ambient heat of internal boiler cabinets without logic drift.
Common Industrial Questions

Is this control board compatible with older 240009241 revisions?
Yes, this is the current production standard replacing legacy part numbers, designed to match original wiring harnesses and mounting footprints precisely.

What safety protocols does the board monitor?
The module manages the safety limit string, including the rollout switch and high-limit aquastat, ensuring the gas valve closes if a fault is detected.

Does this unit support electronic flame rectification?
Yes, it utilizes advanced circuitry for flame signal monitoring, ensuring that the burner remains operational only when a stable flame is confirmed.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$168.46
Utica-Dunkirk 240009241 Control Board
$168.46

Utica-Dunkirk 240009241 Control Board

The Utica-Dunkirk 240009241 Control Board is a specialized integrated boiler control (IBC) designed to manage ignition sequences, temperature monitoring, and safety protocols for high-efficiency hydronic systems. This direct replacement OEM control board is engineered to restore the logic for gas-fired hot water boilers, ensuring precise modulation and sequence control for units including the Utica MGB and Dunkirk DGB series. It features high-durability relays and logic sensors capable of handling the precise electrical loads required by domestic heating applications. For a boiler replacement part of this caliber, field testing confirms its ability to handle cyclic stress while maintaining the integrity of the safety limit circuit. This furnace control circuit board streamlines the diagnostic process with clear LED indicator signals, allowing technicians to verify flame rectification and thermostat calls rapidly. Replacing an outdated or faulty 1012-83-9241A model with this verified 240009241 ensures proper communication between the gas valve, high-limit switch, and the primary circulator pump.

Key Technical Benefits
  • Direct OEM Compatibility: Verified fit for specific Utica and Dunkirk boiler models, reducing field modification time.
  • Reliable Ignition Sequencing: Provides consistent flame sensing and spark ignition control to ensure safe startup cycles.
  • Enhanced Diagnostics: Integrated status indicators assist with HVAC troubleshooting of the safety loop and power delivery.
  • Thermal Management: Engineered to withstand the ambient heat of internal boiler cabinets without logic drift.
Common Industrial Questions

Is this control board compatible with older 240009241 revisions?
Yes, this is the current production standard replacing legacy part numbers, designed to match original wiring harnesses and mounting footprints precisely.

What safety protocols does the board monitor?
The module manages the safety limit string, including the rollout switch and high-limit aquastat, ensuring the gas valve closes if a fault is detected.

Does this unit support electronic flame rectification?
Yes, it utilizes advanced circuitry for flame signal monitoring, ensuring that the burner remains operational only when a stable flame is confirmed.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Utica-Dunkirk 240009241 Control Board is a specialized integrated boiler control (IBC) designed to manage ignition sequences, temperature monitoring, and safety protocols for high-efficiency hydronic systems. This direct replacement OEM control board is engineered to restore the logic for gas-fired hot water boilers, ensuring precise modulation and sequence control for units including the Utica MGB and Dunkirk DGB series. It features high-durability relays and logic sensors capable of handling the precise electrical loads required by domestic heating applications. For a boiler replacement part of this caliber, field testing confirms its ability to handle cyclic stress while maintaining the integrity of the safety limit circuit. This furnace control circuit board streamlines the diagnostic process with clear LED indicator signals, allowing technicians to verify flame rectification and thermostat calls rapidly. Replacing an outdated or faulty 1012-83-9241A model with this verified 240009241 ensures proper communication between the gas valve, high-limit switch, and the primary circulator pump.

Key Technical Benefits
  • Direct OEM Compatibility: Verified fit for specific Utica and Dunkirk boiler models, reducing field modification time.
  • Reliable Ignition Sequencing: Provides consistent flame sensing and spark ignition control to ensure safe startup cycles.
  • Enhanced Diagnostics: Integrated status indicators assist with HVAC troubleshooting of the safety loop and power delivery.
  • Thermal Management: Engineered to withstand the ambient heat of internal boiler cabinets without logic drift.
Common Industrial Questions

Is this control board compatible with older 240009241 revisions?
Yes, this is the current production standard replacing legacy part numbers, designed to match original wiring harnesses and mounting footprints precisely.

What safety protocols does the board monitor?
The module manages the safety limit string, including the rollout switch and high-limit aquastat, ensuring the gas valve closes if a fault is detected.

Does this unit support electronic flame rectification?
Yes, it utilizes advanced circuitry for flame signal monitoring, ensuring that the burner remains operational only when a stable flame is confirmed.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.