The Utica-Dunkirk 240006309 Wire Harness is a critical OEM component designed to integrate the vent damper with the primary control module in DXL, MGB, and MGC series boilers. This vent damper wire harness facilitates the precise automation of the damper assembly, ensuring exhaust gases are safely evacuated during the ignition cycle while preventing standby heat loss when the burner is idle. Built for the rigors of residential and light commercial hydronic systems, this harness utilizes high-temp insulation and rugged connectors to maintain signal integrity between the boiler's 2-wire pilot or intermittent ignition system and the motorized damper motor.

For technicians servicing Utica boilers or Dunkirk heating systems, this harness is the standard replacement for worn or brittle wiring that often leads to intermittent ignition lockouts or damper positioning errors. Proper communication through this link is essential for the boiler to prove the damper is in the fully open position before allowing the gas valve to energize. Ensure you verify the specific boiler replacement parts catalog for your model, as this harness is engineered for direct HVAC compatibility with DXL Series II and MGB series units.

Key Benefits
  • Ensures seamless boiler control system communication for safe damper sequencing.
  • Reduces off-cycle energy loss by maintaining reliable automated damper closure.
  • Direct OEM fit for Utica-Dunkirk 240006309 simplifies field installation and reduces diagnostic time.
  • Heavy-duty construction prevents voltage drops and signal noise in high-heat environments.
  • Maintains system safety by ensuring the damper is fully open during combustion.
Common Questions

Is this wire harness compatible with all Utica boilers?
No, this specific harness is engineered for use with the DXL, MGB, and MGC series. Always cross-reference your specific model and serial number with the factory parts list.

What are the symptoms of a failing vent damper harness?
Common signs include the burner failing to fire despite a call for heat, ignition lockouts, or the damper motor and boiler control module failing to sync during the pre-purge cycle.

Can I use an aftermarket harness instead of the 240006309?
It is highly recommended to use the genuine OEM 240006309 harness to ensure correct pin configurations and wire gauges, which are critical for the safety circuit of the vent damper.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$41.65
Utica-Dunkirk 240006309 Wire Harness
$41.65

Utica-Dunkirk 240006309 Wire Harness

The Utica-Dunkirk 240006309 Wire Harness is a critical OEM component designed to integrate the vent damper with the primary control module in DXL, MGB, and MGC series boilers. This vent damper wire harness facilitates the precise automation of the damper assembly, ensuring exhaust gases are safely evacuated during the ignition cycle while preventing standby heat loss when the burner is idle. Built for the rigors of residential and light commercial hydronic systems, this harness utilizes high-temp insulation and rugged connectors to maintain signal integrity between the boiler's 2-wire pilot or intermittent ignition system and the motorized damper motor.

For technicians servicing Utica boilers or Dunkirk heating systems, this harness is the standard replacement for worn or brittle wiring that often leads to intermittent ignition lockouts or damper positioning errors. Proper communication through this link is essential for the boiler to prove the damper is in the fully open position before allowing the gas valve to energize. Ensure you verify the specific boiler replacement parts catalog for your model, as this harness is engineered for direct HVAC compatibility with DXL Series II and MGB series units.

Key Benefits
  • Ensures seamless boiler control system communication for safe damper sequencing.
  • Reduces off-cycle energy loss by maintaining reliable automated damper closure.
  • Direct OEM fit for Utica-Dunkirk 240006309 simplifies field installation and reduces diagnostic time.
  • Heavy-duty construction prevents voltage drops and signal noise in high-heat environments.
  • Maintains system safety by ensuring the damper is fully open during combustion.
Common Questions

Is this wire harness compatible with all Utica boilers?
No, this specific harness is engineered for use with the DXL, MGB, and MGC series. Always cross-reference your specific model and serial number with the factory parts list.

What are the symptoms of a failing vent damper harness?
Common signs include the burner failing to fire despite a call for heat, ignition lockouts, or the damper motor and boiler control module failing to sync during the pre-purge cycle.

Can I use an aftermarket harness instead of the 240006309?
It is highly recommended to use the genuine OEM 240006309 harness to ensure correct pin configurations and wire gauges, which are critical for the safety circuit of the vent damper.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Utica-Dunkirk 240006309 Wire Harness is a critical OEM component designed to integrate the vent damper with the primary control module in DXL, MGB, and MGC series boilers. This vent damper wire harness facilitates the precise automation of the damper assembly, ensuring exhaust gases are safely evacuated during the ignition cycle while preventing standby heat loss when the burner is idle. Built for the rigors of residential and light commercial hydronic systems, this harness utilizes high-temp insulation and rugged connectors to maintain signal integrity between the boiler's 2-wire pilot or intermittent ignition system and the motorized damper motor.

For technicians servicing Utica boilers or Dunkirk heating systems, this harness is the standard replacement for worn or brittle wiring that often leads to intermittent ignition lockouts or damper positioning errors. Proper communication through this link is essential for the boiler to prove the damper is in the fully open position before allowing the gas valve to energize. Ensure you verify the specific boiler replacement parts catalog for your model, as this harness is engineered for direct HVAC compatibility with DXL Series II and MGB series units.

Key Benefits
  • Ensures seamless boiler control system communication for safe damper sequencing.
  • Reduces off-cycle energy loss by maintaining reliable automated damper closure.
  • Direct OEM fit for Utica-Dunkirk 240006309 simplifies field installation and reduces diagnostic time.
  • Heavy-duty construction prevents voltage drops and signal noise in high-heat environments.
  • Maintains system safety by ensuring the damper is fully open during combustion.
Common Questions

Is this wire harness compatible with all Utica boilers?
No, this specific harness is engineered for use with the DXL, MGB, and MGC series. Always cross-reference your specific model and serial number with the factory parts list.

What are the symptoms of a failing vent damper harness?
Common signs include the burner failing to fire despite a call for heat, ignition lockouts, or the damper motor and boiler control module failing to sync during the pre-purge cycle.

Can I use an aftermarket harness instead of the 240006309?
It is highly recommended to use the genuine OEM 240006309 harness to ensure correct pin configurations and wire gauges, which are critical for the safety circuit of the vent damper.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.