The Tjernlund Products HSJ Power Venter is a professional-grade solution for sidewall venting of natural gas, LP, or oil-fired appliances. Designed to handle flue gas temperatures up to 600°F, this unit is engineered for reliability in residential and light commercial settings where vertical chimneys are impractical or deteriorated. It features a high-performance 115V, 3000 RPM motor with internal fan cooling and thermal protection, ensuring stable operation even under high-demand cycles. The integrated UC1 Universal Control offers unmatched flexibility, allowing for seamless interlock with 24V, 115V, or dry contact burner circuits. This control logic includes adjustable pre-purge and post-purge settings to clear residual flue gases and prevent short-cycling caused by wind or burner startup. For contractors, the HSJ Power Venter provides a compact 4-inch inlet and outlet configuration, simplifying installation in tight spaces while maintaining strict compliance with safety standards via its built-in diaphragm fan proving switch.
Key Benefits- Universal Compatibility: Interlocks with virtually any burner control circuit (24V-120V) using the factory-standard UC1 Universal Control.
- Advanced Diagnostics: Features LED status indicators for real-time troubleshooting of the appliance call, safety circuit, and motor power.
- Optimized Efficiency: Includes a built-in adjustable damper to regulate draft and maximize combustion efficiency for furnaces, boilers, and water heaters.
- Durable Construction: Built with a shaded-pole motor and sintered iron sleeve bearings for long-term use in demanding HVAC environments.
- Retrofit Ready: Directly replaces discontinued HSUL-J, HS115-J, and HST-J models without requiring extensive reconfiguration.
Can this unit be used with multiple appliances?
Yes, the Tjernlund HSJ can co-vent multiple appliances when paired with MAC-Series multiple appliance controls, provided the combined BTU/hr input does not exceed the venter's rated capacity.
What are the purge settings used for?
The pre-purge clears the vent pipe of air before ignition to ensure a clean start, while the post-purge (factory set at 2 minutes) continues to run the motor after the burner shuts down to safely exhaust all remaining combustion byproducts.
Is this model suitable for millivolt systems?
No, standard millivolt water heaters require the additional WHKE kit to properly interlock the fan proving switch with the gas valve safety circuit.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $441.36
-65%$441.36
$154.48Tjernlund Products HSJ Power Venter
The Tjernlund Products HSJ Power Venter is a professional-grade solution for sidewall venting of natural gas, LP, or oil-fired appliances. Designed to handle flue gas temperatures up to 600°F, this unit is engineered for reliability in residential and light commercial settings where vertical chimneys are impractical or deteriorated. It features a high-performance 115V, 3000 RPM motor with internal fan cooling and thermal protection, ensuring stable operation even under high-demand cycles. The integrated UC1 Universal Control offers unmatched flexibility, allowing for seamless interlock with 24V, 115V, or dry contact burner circuits. This control logic includes adjustable pre-purge and post-purge settings to clear residual flue gases and prevent short-cycling caused by wind or burner startup. For contractors, the HSJ Power Venter provides a compact 4-inch inlet and outlet configuration, simplifying installation in tight spaces while maintaining strict compliance with safety standards via its built-in diaphragm fan proving switch.
Key Benefits- Universal Compatibility: Interlocks with virtually any burner control circuit (24V-120V) using the factory-standard UC1 Universal Control.
- Advanced Diagnostics: Features LED status indicators for real-time troubleshooting of the appliance call, safety circuit, and motor power.
- Optimized Efficiency: Includes a built-in adjustable damper to regulate draft and maximize combustion efficiency for furnaces, boilers, and water heaters.
- Durable Construction: Built with a shaded-pole motor and sintered iron sleeve bearings for long-term use in demanding HVAC environments.
- Retrofit Ready: Directly replaces discontinued HSUL-J, HS115-J, and HST-J models without requiring extensive reconfiguration.
Can this unit be used with multiple appliances?
Yes, the Tjernlund HSJ can co-vent multiple appliances when paired with MAC-Series multiple appliance controls, provided the combined BTU/hr input does not exceed the venter's rated capacity.
What are the purge settings used for?
The pre-purge clears the vent pipe of air before ignition to ensure a clean start, while the post-purge (factory set at 2 minutes) continues to run the motor after the burner shuts down to safely exhaust all remaining combustion byproducts.
Is this model suitable for millivolt systems?
No, standard millivolt water heaters require the additional WHKE kit to properly interlock the fan proving switch with the gas valve safety circuit.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Tjernlund Products HSJ Power Venter is a professional-grade solution for sidewall venting of natural gas, LP, or oil-fired appliances. Designed to handle flue gas temperatures up to 600°F, this unit is engineered for reliability in residential and light commercial settings where vertical chimneys are impractical or deteriorated. It features a high-performance 115V, 3000 RPM motor with internal fan cooling and thermal protection, ensuring stable operation even under high-demand cycles. The integrated UC1 Universal Control offers unmatched flexibility, allowing for seamless interlock with 24V, 115V, or dry contact burner circuits. This control logic includes adjustable pre-purge and post-purge settings to clear residual flue gases and prevent short-cycling caused by wind or burner startup. For contractors, the HSJ Power Venter provides a compact 4-inch inlet and outlet configuration, simplifying installation in tight spaces while maintaining strict compliance with safety standards via its built-in diaphragm fan proving switch.
Key Benefits- Universal Compatibility: Interlocks with virtually any burner control circuit (24V-120V) using the factory-standard UC1 Universal Control.
- Advanced Diagnostics: Features LED status indicators for real-time troubleshooting of the appliance call, safety circuit, and motor power.
- Optimized Efficiency: Includes a built-in adjustable damper to regulate draft and maximize combustion efficiency for furnaces, boilers, and water heaters.
- Durable Construction: Built with a shaded-pole motor and sintered iron sleeve bearings for long-term use in demanding HVAC environments.
- Retrofit Ready: Directly replaces discontinued HSUL-J, HS115-J, and HST-J models without requiring extensive reconfiguration.
Can this unit be used with multiple appliances?
Yes, the Tjernlund HSJ can co-vent multiple appliances when paired with MAC-Series multiple appliance controls, provided the combined BTU/hr input does not exceed the venter's rated capacity.
What are the purge settings used for?
The pre-purge clears the vent pipe of air before ignition to ensure a clean start, while the post-purge (factory set at 2 minutes) continues to run the motor after the burner shuts down to safely exhaust all remaining combustion byproducts.
Is this model suitable for millivolt systems?
No, standard millivolt water heaters require the additional WHKE kit to properly interlock the fan proving switch with the gas valve safety circuit.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.