Tecumseh 510-10002 Receiver Tank
HomeStore

Tecumseh 510-10002 Receiver Tank

Tecumseh 510-10002 Receiver Tank

The Tecumseh 510-10002 Receiver Tank is a critical component for technicians maintaining high-side refrigeration system integrity. Specifically engineered for industrial refrigeration setups and commercial walk-in coolers, this steel vessel serves as a reliable reservoir for liquid refrigerant storage during varying load conditions. By acting as a buffer between the condenser and the expansion device, it ensures a constant column of liquid is delivered to the thermal expansion valve (TXV), preventing gas bubbles from entering the liquid line and compromising cooling efficiency. Its rugged, corrosion-resistant steel construction is designed to withstand the high pressures of modern HVACR environments while protecting your compressor from liquid slugging damage.

For contractors looking to improve system reliability, the 510-10002 is a standard OEM replacement part that addresses the common issue of refrigerant starvation during sudden environmental shifts. Its 13.35-inch height and large capacity profile facilitate a stable refrigerant flow, allowing for efficient pump-down procedures without the risk of hydrostatic pressure spikes. When you are diagnosing a system with fluctuating head pressure or unstable superheat, ensuring your liquid line tank is properly sized and functional is the first step in veteran-level troubleshooting.

Key Benefits
  • Optimized System Efficiency: Maintains a steady head of liquid to the expansion valve, eliminating premature flashing and improving overall COP.
  • Compressor Protection: Serves as a primary defense against liquid refrigerant return to the compressor crankcase during low-load intervals.
  • Enhanced Durability: Constructed with heavy-duty steel and a corrosion-resistant finish for long-term survival in demanding plant environments.
  • Simplified Pump-Downs: Sufficient internal volume to hold the system charge, making repairs on the low-side safer and more convenient.
Common Questions

Where should the 510-10002 be placed in the refrigeration circuit?
This receiver tank is installed in the liquid line, immediately following the condenser and prior to the dryer or expansion device.

Is this unit compatible with high-pressure refrigerants?
Yes, this steel receiver is rated for high-pressure industrial refrigeration applications; however, always verify it meets the specific ASME pressure vessel ratings and your system's maximum operating pressure (MOP).

Does a receiver tank impact subcooling?
While the refrigerant at the top of the tank is at saturation, the liquid below the surface can and should maintain subcooling to ensure a solid liquid stream reaches the metering device.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$48.58

Original: $138.80

-65%
Tecumseh 510-10002 Receiver Tank

$138.80

$48.58

Tecumseh 510-10002 Receiver Tank

The Tecumseh 510-10002 Receiver Tank is a critical component for technicians maintaining high-side refrigeration system integrity. Specifically engineered for industrial refrigeration setups and commercial walk-in coolers, this steel vessel serves as a reliable reservoir for liquid refrigerant storage during varying load conditions. By acting as a buffer between the condenser and the expansion device, it ensures a constant column of liquid is delivered to the thermal expansion valve (TXV), preventing gas bubbles from entering the liquid line and compromising cooling efficiency. Its rugged, corrosion-resistant steel construction is designed to withstand the high pressures of modern HVACR environments while protecting your compressor from liquid slugging damage.

For contractors looking to improve system reliability, the 510-10002 is a standard OEM replacement part that addresses the common issue of refrigerant starvation during sudden environmental shifts. Its 13.35-inch height and large capacity profile facilitate a stable refrigerant flow, allowing for efficient pump-down procedures without the risk of hydrostatic pressure spikes. When you are diagnosing a system with fluctuating head pressure or unstable superheat, ensuring your liquid line tank is properly sized and functional is the first step in veteran-level troubleshooting.

Key Benefits
  • Optimized System Efficiency: Maintains a steady head of liquid to the expansion valve, eliminating premature flashing and improving overall COP.
  • Compressor Protection: Serves as a primary defense against liquid refrigerant return to the compressor crankcase during low-load intervals.
  • Enhanced Durability: Constructed with heavy-duty steel and a corrosion-resistant finish for long-term survival in demanding plant environments.
  • Simplified Pump-Downs: Sufficient internal volume to hold the system charge, making repairs on the low-side safer and more convenient.
Common Questions

Where should the 510-10002 be placed in the refrigeration circuit?
This receiver tank is installed in the liquid line, immediately following the condenser and prior to the dryer or expansion device.

Is this unit compatible with high-pressure refrigerants?
Yes, this steel receiver is rated for high-pressure industrial refrigeration applications; however, always verify it meets the specific ASME pressure vessel ratings and your system's maximum operating pressure (MOP).

Does a receiver tank impact subcooling?
While the refrigerant at the top of the tank is at saturation, the liquid below the surface can and should maintain subcooling to ensure a solid liquid stream reaches the metering device.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Tecumseh 510-10002 Receiver Tank is a critical component for technicians maintaining high-side refrigeration system integrity. Specifically engineered for industrial refrigeration setups and commercial walk-in coolers, this steel vessel serves as a reliable reservoir for liquid refrigerant storage during varying load conditions. By acting as a buffer between the condenser and the expansion device, it ensures a constant column of liquid is delivered to the thermal expansion valve (TXV), preventing gas bubbles from entering the liquid line and compromising cooling efficiency. Its rugged, corrosion-resistant steel construction is designed to withstand the high pressures of modern HVACR environments while protecting your compressor from liquid slugging damage.

For contractors looking to improve system reliability, the 510-10002 is a standard OEM replacement part that addresses the common issue of refrigerant starvation during sudden environmental shifts. Its 13.35-inch height and large capacity profile facilitate a stable refrigerant flow, allowing for efficient pump-down procedures without the risk of hydrostatic pressure spikes. When you are diagnosing a system with fluctuating head pressure or unstable superheat, ensuring your liquid line tank is properly sized and functional is the first step in veteran-level troubleshooting.

Key Benefits
  • Optimized System Efficiency: Maintains a steady head of liquid to the expansion valve, eliminating premature flashing and improving overall COP.
  • Compressor Protection: Serves as a primary defense against liquid refrigerant return to the compressor crankcase during low-load intervals.
  • Enhanced Durability: Constructed with heavy-duty steel and a corrosion-resistant finish for long-term survival in demanding plant environments.
  • Simplified Pump-Downs: Sufficient internal volume to hold the system charge, making repairs on the low-side safer and more convenient.
Common Questions

Where should the 510-10002 be placed in the refrigeration circuit?
This receiver tank is installed in the liquid line, immediately following the condenser and prior to the dryer or expansion device.

Is this unit compatible with high-pressure refrigerants?
Yes, this steel receiver is rated for high-pressure industrial refrigeration applications; however, always verify it meets the specific ASME pressure vessel ratings and your system's maximum operating pressure (MOP).

Does a receiver tank impact subcooling?
While the refrigerant at the top of the tank is at saturation, the liquid below the surface can and should maintain subcooling to ensure a solid liquid stream reaches the metering device.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.