Siemens Building Technology RDY2000BN Stat
HomeStore

Siemens Building Technology RDY2000BN Stat

Siemens Building Technology RDY2000BN Stat

For contractors managing light commercial facilities, the Siemens RDY2000BN provides a robust BACnet MS/TP thermostat solution designed for seamless building automation system integration. This commercial room thermostat is engineered to handle complex 24 VAC controlled equipment, supporting multi-stage HVAC control for up to 3-heat/3-cool conventional systems and 4-heat/2-cool heat pump applications. It features onboard temperature and humidity sensors for precise environmental monitoring and includes dedicated routines for independent humidification and dehumidification. To streamline field setup, an intuitive installer setup wizard guides technicians through critical parameters, while BTL listed compatibility ensures reliable communication across open-protocol networks. Whether you are performing a thermostat retrofit or a new construction install, the RDY2000BN maximizes energy efficiency through advanced 7-day occupancy scheduling and demand control ventilation capabilities using CO2 sensor integration. Its password-protected menus and selectable lockout levels provide necessary security against unauthorized setpoint tampering in public or multi-user spaces.

Key Benefits

  • Enhanced Connectivity: Features native BACnet MS/TP communication, allowing it to function as a powerful zone controller within any standard BMS network.
  • Versatile Application: Out-of-the-box support for gas/electric, hydronic, and steam systems, with specialized logic for economizer enable and pre-purging.
  • Flexible I/O: Equipped with three selectable relay outputs and four configurable inputs for remote sensing of occupancy, CO2, or outdoor air temperature.
  • Durable Design: Built with patented Siemens output protection to prevent circuit damage from over-current, reducing field failures during startup.
  • User-Friendly Interface: A 5-inch backlit touchscreen display provides clear status icons for heating/cooling stages, fan operation, and network overrides.

Common Questions

How do I configure the RDY2000BN for a heat pump system?
Access the installer setup menu and use the wizard to select "HP" under system type. You can then define the number of compressor stages and determine if the reversing valve (O/B) energizes in cooling or heating.

Can this thermostat operate without a building management system?
Yes, it can run as a high-performance standalone commercial thermostat. Local schedules and setpoints are stored in non-volatile memory, ensuring configurations remain intact even after power loss.

What type of wire is required for the BACnet network connection?
Siemens recommends using 24 AWG low-capacitance, 1.5 twisted shielded pair cable for the MS/TP run, ensuring the shield is grounded at only one point on the network.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

RDY2000BN is the cross for VT7656B5031B

$169.21

Original: $483.45

-65%
Siemens Building Technology RDY2000BN Stat

$483.45

$169.21

Siemens Building Technology RDY2000BN Stat

For contractors managing light commercial facilities, the Siemens RDY2000BN provides a robust BACnet MS/TP thermostat solution designed for seamless building automation system integration. This commercial room thermostat is engineered to handle complex 24 VAC controlled equipment, supporting multi-stage HVAC control for up to 3-heat/3-cool conventional systems and 4-heat/2-cool heat pump applications. It features onboard temperature and humidity sensors for precise environmental monitoring and includes dedicated routines for independent humidification and dehumidification. To streamline field setup, an intuitive installer setup wizard guides technicians through critical parameters, while BTL listed compatibility ensures reliable communication across open-protocol networks. Whether you are performing a thermostat retrofit or a new construction install, the RDY2000BN maximizes energy efficiency through advanced 7-day occupancy scheduling and demand control ventilation capabilities using CO2 sensor integration. Its password-protected menus and selectable lockout levels provide necessary security against unauthorized setpoint tampering in public or multi-user spaces.

Key Benefits

  • Enhanced Connectivity: Features native BACnet MS/TP communication, allowing it to function as a powerful zone controller within any standard BMS network.
  • Versatile Application: Out-of-the-box support for gas/electric, hydronic, and steam systems, with specialized logic for economizer enable and pre-purging.
  • Flexible I/O: Equipped with three selectable relay outputs and four configurable inputs for remote sensing of occupancy, CO2, or outdoor air temperature.
  • Durable Design: Built with patented Siemens output protection to prevent circuit damage from over-current, reducing field failures during startup.
  • User-Friendly Interface: A 5-inch backlit touchscreen display provides clear status icons for heating/cooling stages, fan operation, and network overrides.

Common Questions

How do I configure the RDY2000BN for a heat pump system?
Access the installer setup menu and use the wizard to select "HP" under system type. You can then define the number of compressor stages and determine if the reversing valve (O/B) energizes in cooling or heating.

Can this thermostat operate without a building management system?
Yes, it can run as a high-performance standalone commercial thermostat. Local schedules and setpoints are stored in non-volatile memory, ensuring configurations remain intact even after power loss.

What type of wire is required for the BACnet network connection?
Siemens recommends using 24 AWG low-capacitance, 1.5 twisted shielded pair cable for the MS/TP run, ensuring the shield is grounded at only one point on the network.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

RDY2000BN is the cross for VT7656B5031B

Product Information

Shipping & Returns

Description

For contractors managing light commercial facilities, the Siemens RDY2000BN provides a robust BACnet MS/TP thermostat solution designed for seamless building automation system integration. This commercial room thermostat is engineered to handle complex 24 VAC controlled equipment, supporting multi-stage HVAC control for up to 3-heat/3-cool conventional systems and 4-heat/2-cool heat pump applications. It features onboard temperature and humidity sensors for precise environmental monitoring and includes dedicated routines for independent humidification and dehumidification. To streamline field setup, an intuitive installer setup wizard guides technicians through critical parameters, while BTL listed compatibility ensures reliable communication across open-protocol networks. Whether you are performing a thermostat retrofit or a new construction install, the RDY2000BN maximizes energy efficiency through advanced 7-day occupancy scheduling and demand control ventilation capabilities using CO2 sensor integration. Its password-protected menus and selectable lockout levels provide necessary security against unauthorized setpoint tampering in public or multi-user spaces.

Key Benefits

  • Enhanced Connectivity: Features native BACnet MS/TP communication, allowing it to function as a powerful zone controller within any standard BMS network.
  • Versatile Application: Out-of-the-box support for gas/electric, hydronic, and steam systems, with specialized logic for economizer enable and pre-purging.
  • Flexible I/O: Equipped with three selectable relay outputs and four configurable inputs for remote sensing of occupancy, CO2, or outdoor air temperature.
  • Durable Design: Built with patented Siemens output protection to prevent circuit damage from over-current, reducing field failures during startup.
  • User-Friendly Interface: A 5-inch backlit touchscreen display provides clear status icons for heating/cooling stages, fan operation, and network overrides.

Common Questions

How do I configure the RDY2000BN for a heat pump system?
Access the installer setup menu and use the wizard to select "HP" under system type. You can then define the number of compressor stages and determine if the reversing valve (O/B) energizes in cooling or heating.

Can this thermostat operate without a building management system?
Yes, it can run as a high-performance standalone commercial thermostat. Local schedules and setpoints are stored in non-volatile memory, ensuring configurations remain intact even after power loss.

What type of wire is required for the BACnet network connection?
Siemens recommends using 24 AWG low-capacitance, 1.5 twisted shielded pair cable for the MS/TP run, ensuring the shield is grounded at only one point on the network.

This item is not eligible for free shipping.