Reznor 201204 Nozzle
HomeStore

Reznor 201204 Nozzle

Reznor 201204 Nozzle

The Reznor 201204 Nozzle is a 30-degree downturn nozzle engineered specifically for high-capacity heating applications. This OEM Reznor replacement part is field-installed to primary heater outlets, allowing for a 25-65 degree discharge air deflection range. Designed for compatibility with Reznor UDAP, UDAS, UDBP, and UDBS unit heater models in the 300 to 400 MBH size range, this nozzle ensures high-velocity air distribution is directed toward the floor for improved thermal stratification. A standard 30 downturn nozzle is vital when mounting units at higher elevations to prevent heat from pooling at the ceiling. The Reznor 201204 features a robust 11.6-pound galvanized steel construction, making it a reliable HVAC discharge nozzle for heavy-duty commercial environments. When installing, remember that 4-point suspension is mandatory for models like the UDAP and UDAS to handle the additional weight and leverage of the nozzle assembly. It integrates seamlessly with existing horizontal louvers to provide a directional air discharge solution that maximizes area coverage and efficiency.

Key Benefits

  • Ensures consistent floor-level comfort by directing airflow via a 30-degree downturn nozzle configuration.
  • Customizable air patterns when combined with adjustable internal louvers for directional discharge.
  • Facilitates Reznor unit heater airflow optimization in high-bay warehouses and shops.
  • Constructed from heavy-gauge material to withstand industrial HVAC system operating conditions.
  • Compatible with Reznor 201204 specific series (300-400), ensuring a precise fit without field modifications.

Common Questions

Which Reznor models are compatible with the 201204 nozzle?
This nozzle is specifically designed for Reznor UDAP, UDAS, UDBP, and UDBS models with a capacity of 300, 350, or 400 MBH. Always verify your heater size before ordering.

How does this 30-degree downturn improve heating efficiency?
By angling the air downward, it forces warm air into the occupied zone rather than letting it rise and settle at the ceiling, reducing energy consumption and increasing the effectiveness of your unit heater.

Is specialized hardware required for installing a downturn nozzle?
Yes, heaters must use a 4-point suspension system to safely support the Reznor 201204 Nozzle. Standard 2-point hanging is insufficient for the added weight and airflow resistance.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$50.16

Original: $143.32

-65%
Reznor 201204 Nozzle

$143.32

$50.16

Reznor 201204 Nozzle

The Reznor 201204 Nozzle is a 30-degree downturn nozzle engineered specifically for high-capacity heating applications. This OEM Reznor replacement part is field-installed to primary heater outlets, allowing for a 25-65 degree discharge air deflection range. Designed for compatibility with Reznor UDAP, UDAS, UDBP, and UDBS unit heater models in the 300 to 400 MBH size range, this nozzle ensures high-velocity air distribution is directed toward the floor for improved thermal stratification. A standard 30 downturn nozzle is vital when mounting units at higher elevations to prevent heat from pooling at the ceiling. The Reznor 201204 features a robust 11.6-pound galvanized steel construction, making it a reliable HVAC discharge nozzle for heavy-duty commercial environments. When installing, remember that 4-point suspension is mandatory for models like the UDAP and UDAS to handle the additional weight and leverage of the nozzle assembly. It integrates seamlessly with existing horizontal louvers to provide a directional air discharge solution that maximizes area coverage and efficiency.

Key Benefits

  • Ensures consistent floor-level comfort by directing airflow via a 30-degree downturn nozzle configuration.
  • Customizable air patterns when combined with adjustable internal louvers for directional discharge.
  • Facilitates Reznor unit heater airflow optimization in high-bay warehouses and shops.
  • Constructed from heavy-gauge material to withstand industrial HVAC system operating conditions.
  • Compatible with Reznor 201204 specific series (300-400), ensuring a precise fit without field modifications.

Common Questions

Which Reznor models are compatible with the 201204 nozzle?
This nozzle is specifically designed for Reznor UDAP, UDAS, UDBP, and UDBS models with a capacity of 300, 350, or 400 MBH. Always verify your heater size before ordering.

How does this 30-degree downturn improve heating efficiency?
By angling the air downward, it forces warm air into the occupied zone rather than letting it rise and settle at the ceiling, reducing energy consumption and increasing the effectiveness of your unit heater.

Is specialized hardware required for installing a downturn nozzle?
Yes, heaters must use a 4-point suspension system to safely support the Reznor 201204 Nozzle. Standard 2-point hanging is insufficient for the added weight and airflow resistance.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Reznor 201204 Nozzle is a 30-degree downturn nozzle engineered specifically for high-capacity heating applications. This OEM Reznor replacement part is field-installed to primary heater outlets, allowing for a 25-65 degree discharge air deflection range. Designed for compatibility with Reznor UDAP, UDAS, UDBP, and UDBS unit heater models in the 300 to 400 MBH size range, this nozzle ensures high-velocity air distribution is directed toward the floor for improved thermal stratification. A standard 30 downturn nozzle is vital when mounting units at higher elevations to prevent heat from pooling at the ceiling. The Reznor 201204 features a robust 11.6-pound galvanized steel construction, making it a reliable HVAC discharge nozzle for heavy-duty commercial environments. When installing, remember that 4-point suspension is mandatory for models like the UDAP and UDAS to handle the additional weight and leverage of the nozzle assembly. It integrates seamlessly with existing horizontal louvers to provide a directional air discharge solution that maximizes area coverage and efficiency.

Key Benefits

  • Ensures consistent floor-level comfort by directing airflow via a 30-degree downturn nozzle configuration.
  • Customizable air patterns when combined with adjustable internal louvers for directional discharge.
  • Facilitates Reznor unit heater airflow optimization in high-bay warehouses and shops.
  • Constructed from heavy-gauge material to withstand industrial HVAC system operating conditions.
  • Compatible with Reznor 201204 specific series (300-400), ensuring a precise fit without field modifications.

Common Questions

Which Reznor models are compatible with the 201204 nozzle?
This nozzle is specifically designed for Reznor UDAP, UDAS, UDBP, and UDBS models with a capacity of 300, 350, or 400 MBH. Always verify your heater size before ordering.

How does this 30-degree downturn improve heating efficiency?
By angling the air downward, it forces warm air into the occupied zone rather than letting it rise and settle at the ceiling, reducing energy consumption and increasing the effectiveness of your unit heater.

Is specialized hardware required for installing a downturn nozzle?
Yes, heaters must use a 4-point suspension system to safely support the Reznor 201204 Nozzle. Standard 2-point hanging is insufficient for the added weight and airflow resistance.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.