Reznor 115802 Ventor Motor Only
HomeStore

Reznor 115802 Ventor Motor Only

Reznor 115802 Ventor Motor Only

Ensure the reliable extraction of combustion gases in high-demand industrial heating applications with the Reznor 115802 Ventor Motor Only. Specifically engineered for technicians servicing Reznor blower-type gas-fired unit heaters, this heavy-duty 460V 3-phase venter motor provides the consistent torque necessary for commercial HVAC venting. Operating at 60Hz, the Reznor RZ115802 motor is a critical OEM replacement part designed for seamless integration with Reznor BE Series models, including the 125, 165, 200, 250, 300, and 400 units, as well as the Reznor 116280 assembly. This industrial-grade inducer motor features a robust 3-phase design that minimizes electrical stress and mechanical wear, ensuring stable performance in harsh environments where reliable HVAC ventilation fan operation is non-negotiable. By maintaining proper draft and airflow, this motor prevents pressure switch faults and ensures the safety and efficiency of the heat exchanger cycle. Note that this is the motor only; mounting plates and venter wheels must be reused or sourced separately.

Key Benefit List:

  • Precision Compatibility: Direct OEM replacement motor for Reznor 116280 and BE Series gas-fired unit heaters.
  • High-Voltage Efficiency: Optimized for 460V / 3-phase electrical systems to provide superior start-up torque and reduced amperage draw.
  • Durable Construction: Engineered for industrial furnace venting with a design that withstands continuous thermal cycling.
  • Optimized Airflow: Critical for maintaining the correct static pressure within the combustion chamber for clean, efficient heating.

Common Questions:

Does this include the blower wheel or mounting bracket?
No, the Reznor 115802 is the ventor motor only. You should inspect your existing impeller and mounting plate for damage and transfer them to the new motor shaft during installation.

Is this motor compatible with 115V or 230V units?
No. This is a 460-volt, 3-phase motor. Verifying your supply voltage and phase configuration against the heater’s rating plate is essential to avoid winding failure upon installation.

What are the signs that my current venter motor needs replacement?
Common indicators for technicians include excessive bearing noise, failure to reach full RPM (causing pressure switch trip-outs), or seized shafts due to moisture and flue gas exposure.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$278.41

Original: $795.47

-65%
Reznor 115802 Ventor Motor Only

$795.47

$278.41

Reznor 115802 Ventor Motor Only

Ensure the reliable extraction of combustion gases in high-demand industrial heating applications with the Reznor 115802 Ventor Motor Only. Specifically engineered for technicians servicing Reznor blower-type gas-fired unit heaters, this heavy-duty 460V 3-phase venter motor provides the consistent torque necessary for commercial HVAC venting. Operating at 60Hz, the Reznor RZ115802 motor is a critical OEM replacement part designed for seamless integration with Reznor BE Series models, including the 125, 165, 200, 250, 300, and 400 units, as well as the Reznor 116280 assembly. This industrial-grade inducer motor features a robust 3-phase design that minimizes electrical stress and mechanical wear, ensuring stable performance in harsh environments where reliable HVAC ventilation fan operation is non-negotiable. By maintaining proper draft and airflow, this motor prevents pressure switch faults and ensures the safety and efficiency of the heat exchanger cycle. Note that this is the motor only; mounting plates and venter wheels must be reused or sourced separately.

Key Benefit List:

  • Precision Compatibility: Direct OEM replacement motor for Reznor 116280 and BE Series gas-fired unit heaters.
  • High-Voltage Efficiency: Optimized for 460V / 3-phase electrical systems to provide superior start-up torque and reduced amperage draw.
  • Durable Construction: Engineered for industrial furnace venting with a design that withstands continuous thermal cycling.
  • Optimized Airflow: Critical for maintaining the correct static pressure within the combustion chamber for clean, efficient heating.

Common Questions:

Does this include the blower wheel or mounting bracket?
No, the Reznor 115802 is the ventor motor only. You should inspect your existing impeller and mounting plate for damage and transfer them to the new motor shaft during installation.

Is this motor compatible with 115V or 230V units?
No. This is a 460-volt, 3-phase motor. Verifying your supply voltage and phase configuration against the heater’s rating plate is essential to avoid winding failure upon installation.

What are the signs that my current venter motor needs replacement?
Common indicators for technicians include excessive bearing noise, failure to reach full RPM (causing pressure switch trip-outs), or seized shafts due to moisture and flue gas exposure.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

Ensure the reliable extraction of combustion gases in high-demand industrial heating applications with the Reznor 115802 Ventor Motor Only. Specifically engineered for technicians servicing Reznor blower-type gas-fired unit heaters, this heavy-duty 460V 3-phase venter motor provides the consistent torque necessary for commercial HVAC venting. Operating at 60Hz, the Reznor RZ115802 motor is a critical OEM replacement part designed for seamless integration with Reznor BE Series models, including the 125, 165, 200, 250, 300, and 400 units, as well as the Reznor 116280 assembly. This industrial-grade inducer motor features a robust 3-phase design that minimizes electrical stress and mechanical wear, ensuring stable performance in harsh environments where reliable HVAC ventilation fan operation is non-negotiable. By maintaining proper draft and airflow, this motor prevents pressure switch faults and ensures the safety and efficiency of the heat exchanger cycle. Note that this is the motor only; mounting plates and venter wheels must be reused or sourced separately.

Key Benefit List:

  • Precision Compatibility: Direct OEM replacement motor for Reznor 116280 and BE Series gas-fired unit heaters.
  • High-Voltage Efficiency: Optimized for 460V / 3-phase electrical systems to provide superior start-up torque and reduced amperage draw.
  • Durable Construction: Engineered for industrial furnace venting with a design that withstands continuous thermal cycling.
  • Optimized Airflow: Critical for maintaining the correct static pressure within the combustion chamber for clean, efficient heating.

Common Questions:

Does this include the blower wheel or mounting bracket?
No, the Reznor 115802 is the ventor motor only. You should inspect your existing impeller and mounting plate for damage and transfer them to the new motor shaft during installation.

Is this motor compatible with 115V or 230V units?
No. This is a 460-volt, 3-phase motor. Verifying your supply voltage and phase configuration against the heater’s rating plate is essential to avoid winding failure upon installation.

What are the signs that my current venter motor needs replacement?
Common indicators for technicians include excessive bearing noise, failure to reach full RPM (causing pressure switch trip-outs), or seized shafts due to moisture and flue gas exposure.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Reznor 115802 Ventor Motor Only | GSIstore