Nidec-US Motors 5481H Motor
HomeStore

Nidec-US Motors 5481H Motor

Nidec-US Motors 5481H Motor

The Nidec-US Motors 5481H Motor is a high-performance, multi-horsepower condenser fan motor engineered for demanding commercial and residential HVACR applications. As part of the Rescue permanent split capacitor motor series, this unit is built to replace 3/4, 1/2, 1/3, and 1/4 HP motors, providing ultimate flexibility for 460V systems. It features a totally enclosed air over (TEAO) enclosure and ball bearings with an all-angle thrust system to ensure durability in extreme ambient temperatures up to 158°F. With its reversible rotation capability and 48Y NEMA frame size, this 1075 RPM motor is a primary choice for technicians needing a reliable replacement for Rheem, Trane, and other major condensing units.

Key Benefits:

  • Versatile Compatibility: Replaces multiple HP ratings (3/4 to 1/4 HP), reducing the need to carry varied truck stock for 460V condenser fan repairs.
  • Thermal Protection: Comes equipped with an automatic reset thermal overload protector to prevent motor failure during high-demand cycles.
  • Durable Construction: Features Class F insulation and a corrosion-resistant treated rotor, specifically designed for continuous duty air over applications.
  • Simplified Installation: Includes 48-inch leads, extended mounting studs, and lead-end mounting holes compatible with Rheem and Trane specifications.

Common Questions:

Can the 5481H be used in 230V systems?
No, this specific model is a dedicated 460V motor. Using it with lower voltage will lead to insufficient torque and potential winding damage.

Is this motor compatible with Variable Frequency Drives (VFD)?
Standard NEMA 48 frame single-phase motors like the 5481H are generally not recommended for VFD applications; they are designed for single-phase 460Vac line power.

What capacitor is required for this Rescue motor?
This motor is designed for use with 370V capacitors. Always verify the MFD rating on the nameplate for the specific horsepower setting being utilized.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$116.59

Original: $333.11

-65%
Nidec-US Motors 5481H Motor

$333.11

$116.59

Nidec-US Motors 5481H Motor

The Nidec-US Motors 5481H Motor is a high-performance, multi-horsepower condenser fan motor engineered for demanding commercial and residential HVACR applications. As part of the Rescue permanent split capacitor motor series, this unit is built to replace 3/4, 1/2, 1/3, and 1/4 HP motors, providing ultimate flexibility for 460V systems. It features a totally enclosed air over (TEAO) enclosure and ball bearings with an all-angle thrust system to ensure durability in extreme ambient temperatures up to 158°F. With its reversible rotation capability and 48Y NEMA frame size, this 1075 RPM motor is a primary choice for technicians needing a reliable replacement for Rheem, Trane, and other major condensing units.

Key Benefits:

  • Versatile Compatibility: Replaces multiple HP ratings (3/4 to 1/4 HP), reducing the need to carry varied truck stock for 460V condenser fan repairs.
  • Thermal Protection: Comes equipped with an automatic reset thermal overload protector to prevent motor failure during high-demand cycles.
  • Durable Construction: Features Class F insulation and a corrosion-resistant treated rotor, specifically designed for continuous duty air over applications.
  • Simplified Installation: Includes 48-inch leads, extended mounting studs, and lead-end mounting holes compatible with Rheem and Trane specifications.

Common Questions:

Can the 5481H be used in 230V systems?
No, this specific model is a dedicated 460V motor. Using it with lower voltage will lead to insufficient torque and potential winding damage.

Is this motor compatible with Variable Frequency Drives (VFD)?
Standard NEMA 48 frame single-phase motors like the 5481H are generally not recommended for VFD applications; they are designed for single-phase 460Vac line power.

What capacitor is required for this Rescue motor?
This motor is designed for use with 370V capacitors. Always verify the MFD rating on the nameplate for the specific horsepower setting being utilized.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Nidec-US Motors 5481H Motor is a high-performance, multi-horsepower condenser fan motor engineered for demanding commercial and residential HVACR applications. As part of the Rescue permanent split capacitor motor series, this unit is built to replace 3/4, 1/2, 1/3, and 1/4 HP motors, providing ultimate flexibility for 460V systems. It features a totally enclosed air over (TEAO) enclosure and ball bearings with an all-angle thrust system to ensure durability in extreme ambient temperatures up to 158°F. With its reversible rotation capability and 48Y NEMA frame size, this 1075 RPM motor is a primary choice for technicians needing a reliable replacement for Rheem, Trane, and other major condensing units.

Key Benefits:

  • Versatile Compatibility: Replaces multiple HP ratings (3/4 to 1/4 HP), reducing the need to carry varied truck stock for 460V condenser fan repairs.
  • Thermal Protection: Comes equipped with an automatic reset thermal overload protector to prevent motor failure during high-demand cycles.
  • Durable Construction: Features Class F insulation and a corrosion-resistant treated rotor, specifically designed for continuous duty air over applications.
  • Simplified Installation: Includes 48-inch leads, extended mounting studs, and lead-end mounting holes compatible with Rheem and Trane specifications.

Common Questions:

Can the 5481H be used in 230V systems?
No, this specific model is a dedicated 460V motor. Using it with lower voltage will lead to insufficient torque and potential winding damage.

Is this motor compatible with Variable Frequency Drives (VFD)?
Standard NEMA 48 frame single-phase motors like the 5481H are generally not recommended for VFD applications; they are designed for single-phase 460Vac line power.

What capacitor is required for this Rescue motor?
This motor is designed for use with 370V capacitors. Always verify the MFD rating on the nameplate for the specific horsepower setting being utilized.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.