Marley Engineered Products 5813-2018-000 Thermostat
HomeStore

Marley Engineered Products 5813-2018-000 Thermostat

Marley Engineered Products 5813-2018-000 Thermostat

The Marley Engineered Products 5813-2018-000 Thermostat is a heavy-duty, field-installable replacement designed for high-demand thermal regulation in commercial and industrial environments. This 2-pole line voltage thermostat is engineered to interface directly with QMark MUH series unit heaters, specifically models MUH35B, MUH35C, and MUH35D, as well as Berko equivalent units. Built for high-amperage HVAC controls, this DPST (Double Pole Single Throw) component provides a positive "off" position, ensuring complete circuit interruption for maintenance safety and system integrity. As a genuine OEM replacement part, it eliminates the calibration drift and contact pitting common in substandard universal alternatives. Integrating this mechanical temperature control into your existing forced-air system or cabinet heater maintains tight differential tolerances, preventing frequent short-cycling. Its rugged internal construction makes it well-suited for manufacturing plants and warehouse heating applications where vibration and temperature fluctuations are constant factors.

Key Benefits
  • Compatible with QMark MUH35 series and Berko industrial unit heaters.
  • Double-pole (DPST) configuration provides a reliable positive off setting for electrical safety.
  • Direct OEM HVAC replacement ensures exact fitment and terminal alignment without field modifications.
  • Designed for high-voltage heating applications typical in industrial and laboratory settings.
  • Simple mechanical interface reduces electronic failure points in harsh operating conditions.
Common Questions
  • Is this thermostat compatible with 480V heaters? This part is typically used with QMark and Berko MUH series heaters; always verify your specific unit's wiring diagram and voltage rating to ensure the amperage load matches this line voltage control.
  • Does this include the mounting hardware or knob? Most Marley replacement thermostats are supplied as the internal control component; it is recommended to retain your existing mounting screws and external dial for installation.
  • Can this be used as a single-pole replacement? While a double-pole thermostat can technically break one side of a line, it is specifically designed to meet NEC requirements for breaking both hot legs in 208V/240V/480V industrial circuits.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$38.39

Original: $109.69

-65%
Marley Engineered Products 5813-2018-000 Thermostat

$109.69

$38.39

Marley Engineered Products 5813-2018-000 Thermostat

The Marley Engineered Products 5813-2018-000 Thermostat is a heavy-duty, field-installable replacement designed for high-demand thermal regulation in commercial and industrial environments. This 2-pole line voltage thermostat is engineered to interface directly with QMark MUH series unit heaters, specifically models MUH35B, MUH35C, and MUH35D, as well as Berko equivalent units. Built for high-amperage HVAC controls, this DPST (Double Pole Single Throw) component provides a positive "off" position, ensuring complete circuit interruption for maintenance safety and system integrity. As a genuine OEM replacement part, it eliminates the calibration drift and contact pitting common in substandard universal alternatives. Integrating this mechanical temperature control into your existing forced-air system or cabinet heater maintains tight differential tolerances, preventing frequent short-cycling. Its rugged internal construction makes it well-suited for manufacturing plants and warehouse heating applications where vibration and temperature fluctuations are constant factors.

Key Benefits
  • Compatible with QMark MUH35 series and Berko industrial unit heaters.
  • Double-pole (DPST) configuration provides a reliable positive off setting for electrical safety.
  • Direct OEM HVAC replacement ensures exact fitment and terminal alignment without field modifications.
  • Designed for high-voltage heating applications typical in industrial and laboratory settings.
  • Simple mechanical interface reduces electronic failure points in harsh operating conditions.
Common Questions
  • Is this thermostat compatible with 480V heaters? This part is typically used with QMark and Berko MUH series heaters; always verify your specific unit's wiring diagram and voltage rating to ensure the amperage load matches this line voltage control.
  • Does this include the mounting hardware or knob? Most Marley replacement thermostats are supplied as the internal control component; it is recommended to retain your existing mounting screws and external dial for installation.
  • Can this be used as a single-pole replacement? While a double-pole thermostat can technically break one side of a line, it is specifically designed to meet NEC requirements for breaking both hot legs in 208V/240V/480V industrial circuits.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Marley Engineered Products 5813-2018-000 Thermostat is a heavy-duty, field-installable replacement designed for high-demand thermal regulation in commercial and industrial environments. This 2-pole line voltage thermostat is engineered to interface directly with QMark MUH series unit heaters, specifically models MUH35B, MUH35C, and MUH35D, as well as Berko equivalent units. Built for high-amperage HVAC controls, this DPST (Double Pole Single Throw) component provides a positive "off" position, ensuring complete circuit interruption for maintenance safety and system integrity. As a genuine OEM replacement part, it eliminates the calibration drift and contact pitting common in substandard universal alternatives. Integrating this mechanical temperature control into your existing forced-air system or cabinet heater maintains tight differential tolerances, preventing frequent short-cycling. Its rugged internal construction makes it well-suited for manufacturing plants and warehouse heating applications where vibration and temperature fluctuations are constant factors.

Key Benefits
  • Compatible with QMark MUH35 series and Berko industrial unit heaters.
  • Double-pole (DPST) configuration provides a reliable positive off setting for electrical safety.
  • Direct OEM HVAC replacement ensures exact fitment and terminal alignment without field modifications.
  • Designed for high-voltage heating applications typical in industrial and laboratory settings.
  • Simple mechanical interface reduces electronic failure points in harsh operating conditions.
Common Questions
  • Is this thermostat compatible with 480V heaters? This part is typically used with QMark and Berko MUH series heaters; always verify your specific unit's wiring diagram and voltage rating to ensure the amperage load matches this line voltage control.
  • Does this include the mounting hardware or knob? Most Marley replacement thermostats are supplied as the internal control component; it is recommended to retain your existing mounting screws and external dial for installation.
  • Can this be used as a single-pole replacement? While a double-pole thermostat can technically break one side of a line, it is specifically designed to meet NEC requirements for breaking both hot legs in 208V/240V/480V industrial circuits.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.