Manitowoc Ice 2007559 Start Relay
HomeStore

Manitowoc Ice 2007559 Start Relay

Manitowoc Ice 2007559 Start Relay

The Manitowoc Ice 2007559 Start Relay is a critical electrical component engineered to initiate the compressor motor in high-demand commercial ice machines. Specifically designed to handle an ampacity of 35A, this genuine OEM part manages the high inrush current required during the startup sequence. In refrigeration cycles, the compressor start relay effectively switches the start capacitors out of the circuit once the motor reaches operating speed, preventing winding damage and ensuring a smooth transition to the run cycle. This relay is essential for maintaining the volumetric efficiency of the refrigeration system, particularly in foodservice ice production environments where frequent cycling occurs. For technicians servicing Manitowoc units, using this HVACR replacement relay ensures exact electrical matching to the original specifications, maintaining system integrity and preventing premature compressor failure. Its compact, robust housing facilitates a secure fit in the control box, providing reliable and repeatable switching for mission-critical cooling systems.

Key Benefits
  • Precise Electrical Timing: Optimized for Manitowoc compressors to ensure the start winding is energized only for the exact duration required.
  • 35A High-Current Capacity: Built to withstand the rigorous electrical demands and thermal stress of commercial ice machine startup.
  • OEM Compatibility: Guaranteed fit for popular models including BD0603W, BY0604A, ICVD1495, and SN0959W, eliminating the risks associated with universal aftermarket components.
  • Heavy-Duty Construction: Designed for high-frequency switching and long-term durability in hot commercial kitchen environments.
Common Questions

How do I test if the 2007559 relay has failed?
Technicians should check for continuity across the terminals and inspect for visible signs of arcing or burnt contacts. If the compressor hums but fails to start, or trips the breaker immediately on startup, the relay is a primary suspect.

Is this relay compatible with 115V or 230V systems?
The 2007559 relay is rated for specific Manitowoc commercial configurations. Always verify the voltage and 35A rating on your existing component or service manual before installation to ensure electrical safety.

Can I use a universal potential relay instead of the 2007559?
While universal relays exist, the 2007559 is an OEM part with calibrated drop-out and pick-up voltages specific to Manitowoc compressors. Using non-specified parts can lead to start winding burnouts or inconsistent harvest cycles.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$28.65

Original: $81.86

-65%
Manitowoc Ice 2007559 Start Relay

$81.86

$28.65

Manitowoc Ice 2007559 Start Relay

The Manitowoc Ice 2007559 Start Relay is a critical electrical component engineered to initiate the compressor motor in high-demand commercial ice machines. Specifically designed to handle an ampacity of 35A, this genuine OEM part manages the high inrush current required during the startup sequence. In refrigeration cycles, the compressor start relay effectively switches the start capacitors out of the circuit once the motor reaches operating speed, preventing winding damage and ensuring a smooth transition to the run cycle. This relay is essential for maintaining the volumetric efficiency of the refrigeration system, particularly in foodservice ice production environments where frequent cycling occurs. For technicians servicing Manitowoc units, using this HVACR replacement relay ensures exact electrical matching to the original specifications, maintaining system integrity and preventing premature compressor failure. Its compact, robust housing facilitates a secure fit in the control box, providing reliable and repeatable switching for mission-critical cooling systems.

Key Benefits
  • Precise Electrical Timing: Optimized for Manitowoc compressors to ensure the start winding is energized only for the exact duration required.
  • 35A High-Current Capacity: Built to withstand the rigorous electrical demands and thermal stress of commercial ice machine startup.
  • OEM Compatibility: Guaranteed fit for popular models including BD0603W, BY0604A, ICVD1495, and SN0959W, eliminating the risks associated with universal aftermarket components.
  • Heavy-Duty Construction: Designed for high-frequency switching and long-term durability in hot commercial kitchen environments.
Common Questions

How do I test if the 2007559 relay has failed?
Technicians should check for continuity across the terminals and inspect for visible signs of arcing or burnt contacts. If the compressor hums but fails to start, or trips the breaker immediately on startup, the relay is a primary suspect.

Is this relay compatible with 115V or 230V systems?
The 2007559 relay is rated for specific Manitowoc commercial configurations. Always verify the voltage and 35A rating on your existing component or service manual before installation to ensure electrical safety.

Can I use a universal potential relay instead of the 2007559?
While universal relays exist, the 2007559 is an OEM part with calibrated drop-out and pick-up voltages specific to Manitowoc compressors. Using non-specified parts can lead to start winding burnouts or inconsistent harvest cycles.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Manitowoc Ice 2007559 Start Relay is a critical electrical component engineered to initiate the compressor motor in high-demand commercial ice machines. Specifically designed to handle an ampacity of 35A, this genuine OEM part manages the high inrush current required during the startup sequence. In refrigeration cycles, the compressor start relay effectively switches the start capacitors out of the circuit once the motor reaches operating speed, preventing winding damage and ensuring a smooth transition to the run cycle. This relay is essential for maintaining the volumetric efficiency of the refrigeration system, particularly in foodservice ice production environments where frequent cycling occurs. For technicians servicing Manitowoc units, using this HVACR replacement relay ensures exact electrical matching to the original specifications, maintaining system integrity and preventing premature compressor failure. Its compact, robust housing facilitates a secure fit in the control box, providing reliable and repeatable switching for mission-critical cooling systems.

Key Benefits
  • Precise Electrical Timing: Optimized for Manitowoc compressors to ensure the start winding is energized only for the exact duration required.
  • 35A High-Current Capacity: Built to withstand the rigorous electrical demands and thermal stress of commercial ice machine startup.
  • OEM Compatibility: Guaranteed fit for popular models including BD0603W, BY0604A, ICVD1495, and SN0959W, eliminating the risks associated with universal aftermarket components.
  • Heavy-Duty Construction: Designed for high-frequency switching and long-term durability in hot commercial kitchen environments.
Common Questions

How do I test if the 2007559 relay has failed?
Technicians should check for continuity across the terminals and inspect for visible signs of arcing or burnt contacts. If the compressor hums but fails to start, or trips the breaker immediately on startup, the relay is a primary suspect.

Is this relay compatible with 115V or 230V systems?
The 2007559 relay is rated for specific Manitowoc commercial configurations. Always verify the voltage and 35A rating on your existing component or service manual before installation to ensure electrical safety.

Can I use a universal potential relay instead of the 2007559?
While universal relays exist, the 2007559 is an OEM part with calibrated drop-out and pick-up voltages specific to Manitowoc compressors. Using non-specified parts can lead to start winding burnouts or inconsistent harvest cycles.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Manitowoc Ice 2007559 Start Relay | GSIstore