When you're troubleshooting a commercial ice machine that’s short-cycling or hitting high-pressure cutouts, the Manitowoc Ice 000014495 Pressure Switch is a critical diagnostic and replacement component for restoring head pressure stability. This genuine OEM fan cycle control is specifically calibrated with a 275/335 PSI range (FCC NO 275/335), designed to monitor refrigerant discharge pressure and regulate condenser fan operation. By maintaining these precise setpoints, the switch ensures that the refrigeration system operates within its thermal envelope, preventing liquid slugging or inefficient harvest cycles. Built for professional HVACR environments, this high-pressure switch provides the reliability necessary for 24/7 ice production in demanding commercial kitchens. Its durable construction handles the rapid cycling common in air-cooled units, making it the standard choice for contractors performing a refrigeration pressure control replacement. This exact-fit part ensures your equipment stays in compliance with original factory specifications, supporting long-term system health without the risks associated with universal after-market controls.

Key Benefits
  • Precise Pressure Calibration: Factory-set at 275/335 PSI to provide accurate fan cycling and stable head pressure.
  • OEM Compatibility: Designed exclusively for Manitowoc ice machines, ensuring a direct interface with existing wiring harnesses and mounting points.
  • System Protection: Acts as a primary monitor to prevent compressor strain caused by improper heat rejection.
  • Optimized Ice Production: Maintains the correct condensing temperature to ensure consistent harvest times and cube quality.
Common Questions

What does the FCC NO 275/335 rating signify?
This indicates the pressure setpoints for the fan cycle control. The switch is engineered to close the circuit and activate the condenser fan at 335 PSI and open it to cut the fan at 275 PSI, keeping the high-side pressure within a functional range.

Can I use this as a universal high-pressure cutout?
No. This is specifically a fan cycling control designed to regulate the condenser fan based on refrigerant pressure. It should not be used as a safety high-pressure cutout unless specified by the manufacturer's wiring diagram for a specific model.

How do I know if my current pressure switch is failing?
Common symptoms include the condenser fan failing to start when head pressure rises, or the fan running continuously even when the system is cold, which can lead to freeze-up issues or poor harvest performance.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$18.93

Original: $54.10

-65%
Manitowoc Ice 000014495 Pressure Switch

$54.10

$18.93

Manitowoc Ice 000014495 Pressure Switch

When you're troubleshooting a commercial ice machine that’s short-cycling or hitting high-pressure cutouts, the Manitowoc Ice 000014495 Pressure Switch is a critical diagnostic and replacement component for restoring head pressure stability. This genuine OEM fan cycle control is specifically calibrated with a 275/335 PSI range (FCC NO 275/335), designed to monitor refrigerant discharge pressure and regulate condenser fan operation. By maintaining these precise setpoints, the switch ensures that the refrigeration system operates within its thermal envelope, preventing liquid slugging or inefficient harvest cycles. Built for professional HVACR environments, this high-pressure switch provides the reliability necessary for 24/7 ice production in demanding commercial kitchens. Its durable construction handles the rapid cycling common in air-cooled units, making it the standard choice for contractors performing a refrigeration pressure control replacement. This exact-fit part ensures your equipment stays in compliance with original factory specifications, supporting long-term system health without the risks associated with universal after-market controls.

Key Benefits
  • Precise Pressure Calibration: Factory-set at 275/335 PSI to provide accurate fan cycling and stable head pressure.
  • OEM Compatibility: Designed exclusively for Manitowoc ice machines, ensuring a direct interface with existing wiring harnesses and mounting points.
  • System Protection: Acts as a primary monitor to prevent compressor strain caused by improper heat rejection.
  • Optimized Ice Production: Maintains the correct condensing temperature to ensure consistent harvest times and cube quality.
Common Questions

What does the FCC NO 275/335 rating signify?
This indicates the pressure setpoints for the fan cycle control. The switch is engineered to close the circuit and activate the condenser fan at 335 PSI and open it to cut the fan at 275 PSI, keeping the high-side pressure within a functional range.

Can I use this as a universal high-pressure cutout?
No. This is specifically a fan cycling control designed to regulate the condenser fan based on refrigerant pressure. It should not be used as a safety high-pressure cutout unless specified by the manufacturer's wiring diagram for a specific model.

How do I know if my current pressure switch is failing?
Common symptoms include the condenser fan failing to start when head pressure rises, or the fan running continuously even when the system is cold, which can lead to freeze-up issues or poor harvest performance.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

When you're troubleshooting a commercial ice machine that’s short-cycling or hitting high-pressure cutouts, the Manitowoc Ice 000014495 Pressure Switch is a critical diagnostic and replacement component for restoring head pressure stability. This genuine OEM fan cycle control is specifically calibrated with a 275/335 PSI range (FCC NO 275/335), designed to monitor refrigerant discharge pressure and regulate condenser fan operation. By maintaining these precise setpoints, the switch ensures that the refrigeration system operates within its thermal envelope, preventing liquid slugging or inefficient harvest cycles. Built for professional HVACR environments, this high-pressure switch provides the reliability necessary for 24/7 ice production in demanding commercial kitchens. Its durable construction handles the rapid cycling common in air-cooled units, making it the standard choice for contractors performing a refrigeration pressure control replacement. This exact-fit part ensures your equipment stays in compliance with original factory specifications, supporting long-term system health without the risks associated with universal after-market controls.

Key Benefits
  • Precise Pressure Calibration: Factory-set at 275/335 PSI to provide accurate fan cycling and stable head pressure.
  • OEM Compatibility: Designed exclusively for Manitowoc ice machines, ensuring a direct interface with existing wiring harnesses and mounting points.
  • System Protection: Acts as a primary monitor to prevent compressor strain caused by improper heat rejection.
  • Optimized Ice Production: Maintains the correct condensing temperature to ensure consistent harvest times and cube quality.
Common Questions

What does the FCC NO 275/335 rating signify?
This indicates the pressure setpoints for the fan cycle control. The switch is engineered to close the circuit and activate the condenser fan at 335 PSI and open it to cut the fan at 275 PSI, keeping the high-side pressure within a functional range.

Can I use this as a universal high-pressure cutout?
No. This is specifically a fan cycling control designed to regulate the condenser fan based on refrigerant pressure. It should not be used as a safety high-pressure cutout unless specified by the manufacturer's wiring diagram for a specific model.

How do I know if my current pressure switch is failing?
Common symptoms include the condenser fan failing to start when head pressure rises, or the fan running continuously even when the system is cold, which can lead to freeze-up issues or poor harvest performance.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.