Lochinvar & A.O. Smith 100111990 Gas Valve
HomeStore

Lochinvar & A.O. Smith 100111990 Gas Valve

Lochinvar & A.O. Smith 100111990 Gas Valve

As a seasoned technician, you know that a call for a Lochinvar Knight boiler gas valve replacement usually means a high-stakes repair where precision is non-negotiable. The Lochinvar & A.O. Smith 100111990 Gas Valve is an OEM-spec modulating gas valve engineered for precise air-to-fuel ratios in high-efficiency hydronic systems. This component is a critical HVAC replacement part designed for specific series of the Lochinvar Knight and A.O. Smith BTR series, ensuring the burner maintains a stable flame even at low firing rates. Replacing an old 100111990 modulating valve restores the system's ability to adjust heat output dynamically, which is essential for maximizing thermal efficiency and reducing mechanical stress on the heat exchanger. This valve is built for natural gas water heater and boiler applications, primarily found in wall-mount or floor-standing condensing units. When troubleshooting flame failure or erratic ignition, verifying the negative pressure at the valve outlet tap is a standard field procedure to confirm this Lochinvar boiler part is functioning within factory tolerances.

Key Benefits for Contractors
  • Precise Modulation: Facilitates seamless adjustments to gas flow, maintaining tight control over combustion and preventing short-cycling.
  • OEM Compatibility: Guaranteed fit for Lochinvar Knight WHB and A.O. Smith BTR high-efficiency units, eliminating the risks associated with universal retrofits.
  • Integrated Redundancy: Features redundant valve seats for enhanced safety and reliable shut-off performance during the prepurge and post-purge cycles.
  • Standardized Fitment: Designed for straightforward integration with existing venturi and flange assemblies to minimize downtime on the job site.
Common Questions & Troubleshooting

How do I confirm if the 100111990 gas valve is faulty?
Technicians should check for proper voltage (typically 24V or 120V depending on the control board) at the valve harness. If voltage is present during the ignition sequence but the manometer shows no change from negative pressure toward zero, the valve is likely stuck or the internal solenoid has failed.

Is this valve compatible with LP (Propane) applications?
While this specifically serves as a natural gas component, it can often be converted or is used in specific LP configurations. Always check the orifice and venturi specifications against the appliance rating plate before final installation.

What causes these modulating valves to fail prematurely?
Common culprits include debris in the gas line or moisture/condensation backup from a blocked flue or drain trap, which can corrode the internal mechanisms and lead to "Gas Valve / Connection" faults on the Smart System interface.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$1,989.65
Lochinvar & A.O. Smith 100111990 Gas Valve
$1,989.65

Lochinvar & A.O. Smith 100111990 Gas Valve

As a seasoned technician, you know that a call for a Lochinvar Knight boiler gas valve replacement usually means a high-stakes repair where precision is non-negotiable. The Lochinvar & A.O. Smith 100111990 Gas Valve is an OEM-spec modulating gas valve engineered for precise air-to-fuel ratios in high-efficiency hydronic systems. This component is a critical HVAC replacement part designed for specific series of the Lochinvar Knight and A.O. Smith BTR series, ensuring the burner maintains a stable flame even at low firing rates. Replacing an old 100111990 modulating valve restores the system's ability to adjust heat output dynamically, which is essential for maximizing thermal efficiency and reducing mechanical stress on the heat exchanger. This valve is built for natural gas water heater and boiler applications, primarily found in wall-mount or floor-standing condensing units. When troubleshooting flame failure or erratic ignition, verifying the negative pressure at the valve outlet tap is a standard field procedure to confirm this Lochinvar boiler part is functioning within factory tolerances.

Key Benefits for Contractors
  • Precise Modulation: Facilitates seamless adjustments to gas flow, maintaining tight control over combustion and preventing short-cycling.
  • OEM Compatibility: Guaranteed fit for Lochinvar Knight WHB and A.O. Smith BTR high-efficiency units, eliminating the risks associated with universal retrofits.
  • Integrated Redundancy: Features redundant valve seats for enhanced safety and reliable shut-off performance during the prepurge and post-purge cycles.
  • Standardized Fitment: Designed for straightforward integration with existing venturi and flange assemblies to minimize downtime on the job site.
Common Questions & Troubleshooting

How do I confirm if the 100111990 gas valve is faulty?
Technicians should check for proper voltage (typically 24V or 120V depending on the control board) at the valve harness. If voltage is present during the ignition sequence but the manometer shows no change from negative pressure toward zero, the valve is likely stuck or the internal solenoid has failed.

Is this valve compatible with LP (Propane) applications?
While this specifically serves as a natural gas component, it can often be converted or is used in specific LP configurations. Always check the orifice and venturi specifications against the appliance rating plate before final installation.

What causes these modulating valves to fail prematurely?
Common culprits include debris in the gas line or moisture/condensation backup from a blocked flue or drain trap, which can corrode the internal mechanisms and lead to "Gas Valve / Connection" faults on the Smart System interface.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

As a seasoned technician, you know that a call for a Lochinvar Knight boiler gas valve replacement usually means a high-stakes repair where precision is non-negotiable. The Lochinvar & A.O. Smith 100111990 Gas Valve is an OEM-spec modulating gas valve engineered for precise air-to-fuel ratios in high-efficiency hydronic systems. This component is a critical HVAC replacement part designed for specific series of the Lochinvar Knight and A.O. Smith BTR series, ensuring the burner maintains a stable flame even at low firing rates. Replacing an old 100111990 modulating valve restores the system's ability to adjust heat output dynamically, which is essential for maximizing thermal efficiency and reducing mechanical stress on the heat exchanger. This valve is built for natural gas water heater and boiler applications, primarily found in wall-mount or floor-standing condensing units. When troubleshooting flame failure or erratic ignition, verifying the negative pressure at the valve outlet tap is a standard field procedure to confirm this Lochinvar boiler part is functioning within factory tolerances.

Key Benefits for Contractors
  • Precise Modulation: Facilitates seamless adjustments to gas flow, maintaining tight control over combustion and preventing short-cycling.
  • OEM Compatibility: Guaranteed fit for Lochinvar Knight WHB and A.O. Smith BTR high-efficiency units, eliminating the risks associated with universal retrofits.
  • Integrated Redundancy: Features redundant valve seats for enhanced safety and reliable shut-off performance during the prepurge and post-purge cycles.
  • Standardized Fitment: Designed for straightforward integration with existing venturi and flange assemblies to minimize downtime on the job site.
Common Questions & Troubleshooting

How do I confirm if the 100111990 gas valve is faulty?
Technicians should check for proper voltage (typically 24V or 120V depending on the control board) at the valve harness. If voltage is present during the ignition sequence but the manometer shows no change from negative pressure toward zero, the valve is likely stuck or the internal solenoid has failed.

Is this valve compatible with LP (Propane) applications?
While this specifically serves as a natural gas component, it can often be converted or is used in specific LP configurations. Always check the orifice and venturi specifications against the appliance rating plate before final installation.

What causes these modulating valves to fail prematurely?
Common culprits include debris in the gas line or moisture/condensation backup from a blocked flue or drain trap, which can corrode the internal mechanisms and lead to "Gas Valve / Connection" faults on the Smart System interface.