Liebert 127185P1S Filter Drier
The Liebert 127185P1S Filter Drier is a critical line component engineered for high-performance precision cooling systems and data center thermal management. Featuring a 3/8 x 1/2 ODF connection, this solid-core drier provides superior moisture removal and acid neutralization within the liquid line. The ODF solder connections ensure a leak-proof interface, essential for maintaining subcooling stages in Vertiv Liebert CRV and Challenger 3000 units. This unit utilizes a specialized desiccant blend optimized for HFC refrigerants and POE oils, preventing the formation of harmful contaminants that lead to compressor failure. For service technicians performing a refrigerant retrofit or system repair, replacing the drier with this OEM-spec component ensures the expansion valve remains free of debris. Its high-capacity filtration media is designed to handle the rapid cycling typical of precision cooling HVACR applications while maintaining a low pressure drop to maximize overall system EER.
Technical Features & Key Benefits- OEM Compatibility: Specifically engineered for Liebert precision cooling systems to maintain strict environmental tolerances.
- Advanced Desiccant Core: High-density particulate filtration protects the TXV orifice from copper oxides and metallic shavings.
- System Longevity: Effectively sequesters moisture and acid to prevent copper plating and motor winding insulation breakdown.
- Durable Construction: Corrosion-resistant shell with 3/8 inch by 1/2 inch ODF stubs for versatile installation in tight cabinetry.
What is the micron rating for the Liebert 127185P1S?
This drier is designed for fine-particle filtration, typically capturing contaminants down to 20 microns to protect sensitive control components in the refrigeration circuit.
Can this drier be used with both R-407C and R-410A?
Yes, the internal desiccant is compatible with high-pressure R-410A systems and standard R-22 or R-407C blends, provided the POE or PVE oil chemistry is utilized.
Which direction should the 127185P1S be installed?
This is a unidirectional filter drier. Ensure the flow arrow on the canister points toward the metering device to ensure proper filtration and prevent core bypass.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Liebert 127185P1S Filter Drier
The Liebert 127185P1S Filter Drier is a critical line component engineered for high-performance precision cooling systems and data center thermal management. Featuring a 3/8 x 1/2 ODF connection, this solid-core drier provides superior moisture removal and acid neutralization within the liquid line. The ODF solder connections ensure a leak-proof interface, essential for maintaining subcooling stages in Vertiv Liebert CRV and Challenger 3000 units. This unit utilizes a specialized desiccant blend optimized for HFC refrigerants and POE oils, preventing the formation of harmful contaminants that lead to compressor failure. For service technicians performing a refrigerant retrofit or system repair, replacing the drier with this OEM-spec component ensures the expansion valve remains free of debris. Its high-capacity filtration media is designed to handle the rapid cycling typical of precision cooling HVACR applications while maintaining a low pressure drop to maximize overall system EER.
Technical Features & Key Benefits- OEM Compatibility: Specifically engineered for Liebert precision cooling systems to maintain strict environmental tolerances.
- Advanced Desiccant Core: High-density particulate filtration protects the TXV orifice from copper oxides and metallic shavings.
- System Longevity: Effectively sequesters moisture and acid to prevent copper plating and motor winding insulation breakdown.
- Durable Construction: Corrosion-resistant shell with 3/8 inch by 1/2 inch ODF stubs for versatile installation in tight cabinetry.
What is the micron rating for the Liebert 127185P1S?
This drier is designed for fine-particle filtration, typically capturing contaminants down to 20 microns to protect sensitive control components in the refrigeration circuit.
Can this drier be used with both R-407C and R-410A?
Yes, the internal desiccant is compatible with high-pressure R-410A systems and standard R-22 or R-407C blends, provided the POE or PVE oil chemistry is utilized.
Which direction should the 127185P1S be installed?
This is a unidirectional filter drier. Ensure the flow arrow on the canister points toward the metering device to ensure proper filtration and prevent core bypass.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Liebert 127185P1S Filter Drier is a critical line component engineered for high-performance precision cooling systems and data center thermal management. Featuring a 3/8 x 1/2 ODF connection, this solid-core drier provides superior moisture removal and acid neutralization within the liquid line. The ODF solder connections ensure a leak-proof interface, essential for maintaining subcooling stages in Vertiv Liebert CRV and Challenger 3000 units. This unit utilizes a specialized desiccant blend optimized for HFC refrigerants and POE oils, preventing the formation of harmful contaminants that lead to compressor failure. For service technicians performing a refrigerant retrofit or system repair, replacing the drier with this OEM-spec component ensures the expansion valve remains free of debris. Its high-capacity filtration media is designed to handle the rapid cycling typical of precision cooling HVACR applications while maintaining a low pressure drop to maximize overall system EER.
Technical Features & Key Benefits- OEM Compatibility: Specifically engineered for Liebert precision cooling systems to maintain strict environmental tolerances.
- Advanced Desiccant Core: High-density particulate filtration protects the TXV orifice from copper oxides and metallic shavings.
- System Longevity: Effectively sequesters moisture and acid to prevent copper plating and motor winding insulation breakdown.
- Durable Construction: Corrosion-resistant shell with 3/8 inch by 1/2 inch ODF stubs for versatile installation in tight cabinetry.
What is the micron rating for the Liebert 127185P1S?
This drier is designed for fine-particle filtration, typically capturing contaminants down to 20 microns to protect sensitive control components in the refrigeration circuit.
Can this drier be used with both R-407C and R-410A?
Yes, the internal desiccant is compatible with high-pressure R-410A systems and standard R-22 or R-407C blends, provided the POE or PVE oil chemistry is utilized.
Which direction should the 127185P1S be installed?
This is a unidirectional filter drier. Ensure the flow arrow on the canister points toward the metering device to ensure proper filtration and prevent core bypass.