Hartland Controls CON-3/24/30 Contactor
HomeStore

Hartland Controls CON-3/24/30 Contactor

Hartland Controls CON-3/24/30 Contactor

The Hartland Controls CON-3/24/30 is a heavy-duty definite purpose contactor engineered for consistent performance in demanding HVACR and industrial motor control applications. This 3-pole contactor is rated for 30 FLA (Full Load Amps) and features a 24V AC coil compatible with standard 50/60Hz control circuits. Designed to handle inductive loads with a 120A locked rotor current (LRC) at 600V, the CON-3/24/30 utilizes high-grade silver nickel contacts to minimize arcing and ensure superior conductivity over a wide temperature range of -40°F to 149°F. Field technicians will find the chassis mount design and hybrid termination options?including #10-32 screw power terminals and 0.25-inch quick-connect coil terminals?ideal for fast, secure integration into existing control panels for compressors, fans, and resistive heating elements.

Key Benefits for Contractors:
  • Enhanced Durability: Silver nickel contact material resists welding and pitting, maintaining low contact resistance in high-cycle environments.
  • Specific Compliance: Meets ARI 780/790 standards for definite purpose contactors, ensuring seamless HVAC part replacement.
  • High Insulation Rating: Features a 2200V isolation voltage rating for maximum safety and protection against electrical breakdown.
  • Versatile Mounting: Standard chassis mounting footprint allows for direct replacement of most OEM 3-pole 30A contactors.
Common Questions:

Can I use this contactor for single-phase or three-phase equipment?
The Hartland Controls CON-3/24/30 is a 3-pole unit specifically designed for three-phase systems, but it can be used for single-phase applications by utilizing only two of the poles if the amperage requirements are met.

What is the resistive load rating compared to the inductive rating?
While this unit is rated at 30 Amps for inductive (motor) loads, it is rated for up to 40 Amps for resistive loads, such as electric heating elements, at voltages up to 600 VAC.

Will the 24V coil operate on DC power?
No, this model features a 24 VAC 50/60Hz coil. Using a DC power source will result in coil failure; always verify your control circuit voltage before installation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$11.13

Original: $31.79

-65%
Hartland Controls CON-3/24/30 Contactor

$31.79

$11.13

Hartland Controls CON-3/24/30 Contactor

The Hartland Controls CON-3/24/30 is a heavy-duty definite purpose contactor engineered for consistent performance in demanding HVACR and industrial motor control applications. This 3-pole contactor is rated for 30 FLA (Full Load Amps) and features a 24V AC coil compatible with standard 50/60Hz control circuits. Designed to handle inductive loads with a 120A locked rotor current (LRC) at 600V, the CON-3/24/30 utilizes high-grade silver nickel contacts to minimize arcing and ensure superior conductivity over a wide temperature range of -40°F to 149°F. Field technicians will find the chassis mount design and hybrid termination options?including #10-32 screw power terminals and 0.25-inch quick-connect coil terminals?ideal for fast, secure integration into existing control panels for compressors, fans, and resistive heating elements.

Key Benefits for Contractors:
  • Enhanced Durability: Silver nickel contact material resists welding and pitting, maintaining low contact resistance in high-cycle environments.
  • Specific Compliance: Meets ARI 780/790 standards for definite purpose contactors, ensuring seamless HVAC part replacement.
  • High Insulation Rating: Features a 2200V isolation voltage rating for maximum safety and protection against electrical breakdown.
  • Versatile Mounting: Standard chassis mounting footprint allows for direct replacement of most OEM 3-pole 30A contactors.
Common Questions:

Can I use this contactor for single-phase or three-phase equipment?
The Hartland Controls CON-3/24/30 is a 3-pole unit specifically designed for three-phase systems, but it can be used for single-phase applications by utilizing only two of the poles if the amperage requirements are met.

What is the resistive load rating compared to the inductive rating?
While this unit is rated at 30 Amps for inductive (motor) loads, it is rated for up to 40 Amps for resistive loads, such as electric heating elements, at voltages up to 600 VAC.

Will the 24V coil operate on DC power?
No, this model features a 24 VAC 50/60Hz coil. Using a DC power source will result in coil failure; always verify your control circuit voltage before installation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Hartland Controls CON-3/24/30 is a heavy-duty definite purpose contactor engineered for consistent performance in demanding HVACR and industrial motor control applications. This 3-pole contactor is rated for 30 FLA (Full Load Amps) and features a 24V AC coil compatible with standard 50/60Hz control circuits. Designed to handle inductive loads with a 120A locked rotor current (LRC) at 600V, the CON-3/24/30 utilizes high-grade silver nickel contacts to minimize arcing and ensure superior conductivity over a wide temperature range of -40°F to 149°F. Field technicians will find the chassis mount design and hybrid termination options?including #10-32 screw power terminals and 0.25-inch quick-connect coil terminals?ideal for fast, secure integration into existing control panels for compressors, fans, and resistive heating elements.

Key Benefits for Contractors:
  • Enhanced Durability: Silver nickel contact material resists welding and pitting, maintaining low contact resistance in high-cycle environments.
  • Specific Compliance: Meets ARI 780/790 standards for definite purpose contactors, ensuring seamless HVAC part replacement.
  • High Insulation Rating: Features a 2200V isolation voltage rating for maximum safety and protection against electrical breakdown.
  • Versatile Mounting: Standard chassis mounting footprint allows for direct replacement of most OEM 3-pole 30A contactors.
Common Questions:

Can I use this contactor for single-phase or three-phase equipment?
The Hartland Controls CON-3/24/30 is a 3-pole unit specifically designed for three-phase systems, but it can be used for single-phase applications by utilizing only two of the poles if the amperage requirements are met.

What is the resistive load rating compared to the inductive rating?
While this unit is rated at 30 Amps for inductive (motor) loads, it is rated for up to 40 Amps for resistive loads, such as electric heating elements, at voltages up to 600 VAC.

Will the 24V coil operate on DC power?
No, this model features a 24 VAC 50/60Hz coil. Using a DC power source will result in coil failure; always verify your control circuit voltage before installation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.