Danfoss 067N9215 Valve
The Danfoss 067N9215 is a high-capacity Type TGEL 40 thermostatic expansion valve engineered for demanding R410A refrigeration and air conditioning applications. Featuring a robust straight body design and a 31-ton capacity, this externally equalized TXV ensures precise refrigerant metering across varying load conditions. It is built with a 7/8" ODF inlet and a 1 3/8" ODF outlet connection, optimized for high-pressure systems with a Maximum Operating Pressure (MOP) of 667 PSI. The integration of a number 26 orifice and a 60-inch capillary tube provides the technical flexibility required for large-scale evaporators, effectively preventing liquid slugging while maintaining optimal superheat. For contractors performing a TXV replacement, the stainless steel power element and laser-welded construction offer superior durability in commercial environments. This Danfoss expansion valve includes a bulb strap for secure thermal contact, ensuring accurate pressure equalization and system efficiency.
Key Benefits- High-Pressure Compatibility: Rated for 667 PSI MOP, specifically designed to handle the thermal demands of R410A systems.
- Precise Superheat Control: Features an adjustable superheat setting and a number 26 orifice for fine-tuned refrigerant flow.
- Reliable Construction: Hermetically sealed straight body with an externally equalized port to protect the compressor from liquid carryover.
- Large Capacity Output: Delivers a consistent 31-ton capacity, making it ideal for heavy-duty commercial HVAC units.
- Simplified Installation: Comes with a 60-inch capillary tube and inclusive bulb strap for versatile mounting and accurate sensing.
Is the Danfoss 067N9215 suitable for bi-flow applications?
Yes, the TGE series is designed for bi-flow operation, making it highly effective for heat pump systems where refrigerant flow direction changes.
What is the purpose of the 667 PSI MOP charge on this valve?
The Maximum Operating Pressure (MOP) charge protects the compressor motor against excessive evaporating pressure during start-up or heavy load periods.
Can I use this TXV with refrigerants other than R410A?
This specific code (067N9215) is optimized and charged for R410A. Using it with incompatible refrigerants will result in incorrect superheat levels and potential system failure.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $373.87
-65%$373.87
$130.85Danfoss 067N9215 Valve
The Danfoss 067N9215 is a high-capacity Type TGEL 40 thermostatic expansion valve engineered for demanding R410A refrigeration and air conditioning applications. Featuring a robust straight body design and a 31-ton capacity, this externally equalized TXV ensures precise refrigerant metering across varying load conditions. It is built with a 7/8" ODF inlet and a 1 3/8" ODF outlet connection, optimized for high-pressure systems with a Maximum Operating Pressure (MOP) of 667 PSI. The integration of a number 26 orifice and a 60-inch capillary tube provides the technical flexibility required for large-scale evaporators, effectively preventing liquid slugging while maintaining optimal superheat. For contractors performing a TXV replacement, the stainless steel power element and laser-welded construction offer superior durability in commercial environments. This Danfoss expansion valve includes a bulb strap for secure thermal contact, ensuring accurate pressure equalization and system efficiency.
Key Benefits- High-Pressure Compatibility: Rated for 667 PSI MOP, specifically designed to handle the thermal demands of R410A systems.
- Precise Superheat Control: Features an adjustable superheat setting and a number 26 orifice for fine-tuned refrigerant flow.
- Reliable Construction: Hermetically sealed straight body with an externally equalized port to protect the compressor from liquid carryover.
- Large Capacity Output: Delivers a consistent 31-ton capacity, making it ideal for heavy-duty commercial HVAC units.
- Simplified Installation: Comes with a 60-inch capillary tube and inclusive bulb strap for versatile mounting and accurate sensing.
Is the Danfoss 067N9215 suitable for bi-flow applications?
Yes, the TGE series is designed for bi-flow operation, making it highly effective for heat pump systems where refrigerant flow direction changes.
What is the purpose of the 667 PSI MOP charge on this valve?
The Maximum Operating Pressure (MOP) charge protects the compressor motor against excessive evaporating pressure during start-up or heavy load periods.
Can I use this TXV with refrigerants other than R410A?
This specific code (067N9215) is optimized and charged for R410A. Using it with incompatible refrigerants will result in incorrect superheat levels and potential system failure.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Danfoss 067N9215 is a high-capacity Type TGEL 40 thermostatic expansion valve engineered for demanding R410A refrigeration and air conditioning applications. Featuring a robust straight body design and a 31-ton capacity, this externally equalized TXV ensures precise refrigerant metering across varying load conditions. It is built with a 7/8" ODF inlet and a 1 3/8" ODF outlet connection, optimized for high-pressure systems with a Maximum Operating Pressure (MOP) of 667 PSI. The integration of a number 26 orifice and a 60-inch capillary tube provides the technical flexibility required for large-scale evaporators, effectively preventing liquid slugging while maintaining optimal superheat. For contractors performing a TXV replacement, the stainless steel power element and laser-welded construction offer superior durability in commercial environments. This Danfoss expansion valve includes a bulb strap for secure thermal contact, ensuring accurate pressure equalization and system efficiency.
Key Benefits- High-Pressure Compatibility: Rated for 667 PSI MOP, specifically designed to handle the thermal demands of R410A systems.
- Precise Superheat Control: Features an adjustable superheat setting and a number 26 orifice for fine-tuned refrigerant flow.
- Reliable Construction: Hermetically sealed straight body with an externally equalized port to protect the compressor from liquid carryover.
- Large Capacity Output: Delivers a consistent 31-ton capacity, making it ideal for heavy-duty commercial HVAC units.
- Simplified Installation: Comes with a 60-inch capillary tube and inclusive bulb strap for versatile mounting and accurate sensing.
Is the Danfoss 067N9215 suitable for bi-flow applications?
Yes, the TGE series is designed for bi-flow operation, making it highly effective for heat pump systems where refrigerant flow direction changes.
What is the purpose of the 667 PSI MOP charge on this valve?
The Maximum Operating Pressure (MOP) charge protects the compressor motor against excessive evaporating pressure during start-up or heavy load periods.
Can I use this TXV with refrigerants other than R410A?
This specific code (067N9215) is optimized and charged for R410A. Using it with incompatible refrigerants will result in incorrect superheat levels and potential system failure.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.