Danfoss 067N9210 Valve
HomeStore

Danfoss 067N9210 Valve

Danfoss 067N9210 Valve

The Danfoss 067N9210 (Type TGEL 20) is a heavy-duty thermostatic expansion valve (TXV) engineered for high-capacity R410A systems. Featuring a 15-ton cooling capacity and an externally equalized design, this valve provides precise refrigerant metering essential for maintaining evaporator efficiency in commercial AC and refrigeration units. The balanced port design is a critical technical advantage, neutralizing the impact of head pressure fluctuations to ensure stable superheat control across a wide range of operating conditions. Built with a straightway brass body and 5/8" x 1-1/8" ODF solder connections, the 067N9210 includes a 60-inch capillary tube and a number 12.5 orifice. With an MOP point of 667 PSI and a maximum working pressure of 711 PSIG, this Danfoss TGE valve is a reliable solution for technicians needing to optimize subcooling and prevent liquid slugging in high-demand environments.

Key Benefits:

  • Stable Superheat Control: The balanced port architecture ensures consistent performance even during significant ambient temperature swings or varying head pressures.
  • Optimized Efficiency: Precision-machined No. 12.5 orifice provides accurate mass flow for 15-ton systems, improving overall SEER/EER ratings.
  • Durable Construction: Features laser-welded stainless steel power elements for increased diaphragm life and resistance to high-pressure cycles.
  • Installation Ready: Includes a bulb strap and long 60-inch capillary for flexible placement on larger evaporator manifolds.
  • High Pressure Rating: Specifically designed for R410A operating parameters with a safety-tested 711 PSIG maximum limit.

Common Questions:

Is the Danfoss 067N9210 bi-flow capable?
Yes, the TGE type valve features a bi-flow design, allowing for efficient operation in heat pump applications where refrigerant flow direction changes during the defrost cycle.

What is the purpose of the 667 PSI MOP?
The Maximum Operating Pressure (MOP) protects the compressor motor by limiting the suction pressure during startup or after defrost, preventing overload in high-load conditions.

Does this valve require an external equalizer line?
Yes, because this is an externally equalized TXV, it requires a 1/4" ODF connection to the suction line to accurately sense evaporator pressure and compensate for pressure drops.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$81.01

Original: $231.47

-65%
Danfoss 067N9210 Valve

$231.47

$81.01

Danfoss 067N9210 Valve

The Danfoss 067N9210 (Type TGEL 20) is a heavy-duty thermostatic expansion valve (TXV) engineered for high-capacity R410A systems. Featuring a 15-ton cooling capacity and an externally equalized design, this valve provides precise refrigerant metering essential for maintaining evaporator efficiency in commercial AC and refrigeration units. The balanced port design is a critical technical advantage, neutralizing the impact of head pressure fluctuations to ensure stable superheat control across a wide range of operating conditions. Built with a straightway brass body and 5/8" x 1-1/8" ODF solder connections, the 067N9210 includes a 60-inch capillary tube and a number 12.5 orifice. With an MOP point of 667 PSI and a maximum working pressure of 711 PSIG, this Danfoss TGE valve is a reliable solution for technicians needing to optimize subcooling and prevent liquid slugging in high-demand environments.

Key Benefits:

  • Stable Superheat Control: The balanced port architecture ensures consistent performance even during significant ambient temperature swings or varying head pressures.
  • Optimized Efficiency: Precision-machined No. 12.5 orifice provides accurate mass flow for 15-ton systems, improving overall SEER/EER ratings.
  • Durable Construction: Features laser-welded stainless steel power elements for increased diaphragm life and resistance to high-pressure cycles.
  • Installation Ready: Includes a bulb strap and long 60-inch capillary for flexible placement on larger evaporator manifolds.
  • High Pressure Rating: Specifically designed for R410A operating parameters with a safety-tested 711 PSIG maximum limit.

Common Questions:

Is the Danfoss 067N9210 bi-flow capable?
Yes, the TGE type valve features a bi-flow design, allowing for efficient operation in heat pump applications where refrigerant flow direction changes during the defrost cycle.

What is the purpose of the 667 PSI MOP?
The Maximum Operating Pressure (MOP) protects the compressor motor by limiting the suction pressure during startup or after defrost, preventing overload in high-load conditions.

Does this valve require an external equalizer line?
Yes, because this is an externally equalized TXV, it requires a 1/4" ODF connection to the suction line to accurately sense evaporator pressure and compensate for pressure drops.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Danfoss 067N9210 (Type TGEL 20) is a heavy-duty thermostatic expansion valve (TXV) engineered for high-capacity R410A systems. Featuring a 15-ton cooling capacity and an externally equalized design, this valve provides precise refrigerant metering essential for maintaining evaporator efficiency in commercial AC and refrigeration units. The balanced port design is a critical technical advantage, neutralizing the impact of head pressure fluctuations to ensure stable superheat control across a wide range of operating conditions. Built with a straightway brass body and 5/8" x 1-1/8" ODF solder connections, the 067N9210 includes a 60-inch capillary tube and a number 12.5 orifice. With an MOP point of 667 PSI and a maximum working pressure of 711 PSIG, this Danfoss TGE valve is a reliable solution for technicians needing to optimize subcooling and prevent liquid slugging in high-demand environments.

Key Benefits:

  • Stable Superheat Control: The balanced port architecture ensures consistent performance even during significant ambient temperature swings or varying head pressures.
  • Optimized Efficiency: Precision-machined No. 12.5 orifice provides accurate mass flow for 15-ton systems, improving overall SEER/EER ratings.
  • Durable Construction: Features laser-welded stainless steel power elements for increased diaphragm life and resistance to high-pressure cycles.
  • Installation Ready: Includes a bulb strap and long 60-inch capillary for flexible placement on larger evaporator manifolds.
  • High Pressure Rating: Specifically designed for R410A operating parameters with a safety-tested 711 PSIG maximum limit.

Common Questions:

Is the Danfoss 067N9210 bi-flow capable?
Yes, the TGE type valve features a bi-flow design, allowing for efficient operation in heat pump applications where refrigerant flow direction changes during the defrost cycle.

What is the purpose of the 667 PSI MOP?
The Maximum Operating Pressure (MOP) protects the compressor motor by limiting the suction pressure during startup or after defrost, preventing overload in high-load conditions.

Does this valve require an external equalizer line?
Yes, because this is an externally equalized TXV, it requires a 1/4" ODF connection to the suction line to accurately sense evaporator pressure and compensate for pressure drops.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.