Danfoss 034L0094 Valve
The Danfoss 034L0094 KVR 22 condensing pressure regulator is a vital component for technicians maintaining system stability in air-cooled condensers. Designed for 7/8" solder ODF connections, this condenser pressure regulator ensures a consistent and sufficiently high head pressure during winter operation or low ambient conditions. By throttling the liquid flow from the condenser to the receiver, it effectively reduces the effective condenser surface area to keep your HVACR refrigeration system operating within its design parameters. This hermetically brazed unit features a pulsation damping design and stainless steel bellows to enhance service life in demanding commercial environments. With an adjustment range of 73 to 254 psig and a factory setting of 145 psig, the KVR 22 regulator provides the precise control needed to prevent liquid slugging and ensure reliable expansion valve performance. It is compatible with a wide array of refrigerants, including R22, R134a, R404A, and R507, making it a versatile choice for retrofit and new installations alike.
Key Benefits:- Optimized Head Pressure Control: Maintains consistent receiver pressure to prevent system failure during cold-weather startups.
- Refined Technical Build: Features a stainless steel bellows and a compact angle design for reliable installation in restricted spaces.
- Integrated Service Access: Includes a 1/4 inch Schrader valve access port for rapid pressure gauge connection and troubleshooting.
- High Pressure Resilience: Rated for a maximum working pressure (MWP) of 406 psig (28 bar), suitable for high-pressure refrigerants.
- How do I adjust the pressure setting on the KVR 22? Remove the protective cap and turn the adjustment spindle. Clockwise increases the opening pressure, while counter-clockwise decreases it. Always use a high-pressure gauge at the access port for precise calibration.
- Where is the ideal placement for this valve? In most air-cooled systems, the Danfoss 034L0094 is installed in the liquid line between the condenser and the receiver to regulate liquid flow based on inlet pressure.
- Is a check valve required with this installation? If the regulator is installed in a hot gas bypass application, a check valve (like the NRD) should be utilized to prevent refrigerant migration back into the cold condenser.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $150.31
-65%$150.31
$52.61Danfoss 034L0094 Valve
The Danfoss 034L0094 KVR 22 condensing pressure regulator is a vital component for technicians maintaining system stability in air-cooled condensers. Designed for 7/8" solder ODF connections, this condenser pressure regulator ensures a consistent and sufficiently high head pressure during winter operation or low ambient conditions. By throttling the liquid flow from the condenser to the receiver, it effectively reduces the effective condenser surface area to keep your HVACR refrigeration system operating within its design parameters. This hermetically brazed unit features a pulsation damping design and stainless steel bellows to enhance service life in demanding commercial environments. With an adjustment range of 73 to 254 psig and a factory setting of 145 psig, the KVR 22 regulator provides the precise control needed to prevent liquid slugging and ensure reliable expansion valve performance. It is compatible with a wide array of refrigerants, including R22, R134a, R404A, and R507, making it a versatile choice for retrofit and new installations alike.
Key Benefits:- Optimized Head Pressure Control: Maintains consistent receiver pressure to prevent system failure during cold-weather startups.
- Refined Technical Build: Features a stainless steel bellows and a compact angle design for reliable installation in restricted spaces.
- Integrated Service Access: Includes a 1/4 inch Schrader valve access port for rapid pressure gauge connection and troubleshooting.
- High Pressure Resilience: Rated for a maximum working pressure (MWP) of 406 psig (28 bar), suitable for high-pressure refrigerants.
- How do I adjust the pressure setting on the KVR 22? Remove the protective cap and turn the adjustment spindle. Clockwise increases the opening pressure, while counter-clockwise decreases it. Always use a high-pressure gauge at the access port for precise calibration.
- Where is the ideal placement for this valve? In most air-cooled systems, the Danfoss 034L0094 is installed in the liquid line between the condenser and the receiver to regulate liquid flow based on inlet pressure.
- Is a check valve required with this installation? If the regulator is installed in a hot gas bypass application, a check valve (like the NRD) should be utilized to prevent refrigerant migration back into the cold condenser.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Danfoss 034L0094 KVR 22 condensing pressure regulator is a vital component for technicians maintaining system stability in air-cooled condensers. Designed for 7/8" solder ODF connections, this condenser pressure regulator ensures a consistent and sufficiently high head pressure during winter operation or low ambient conditions. By throttling the liquid flow from the condenser to the receiver, it effectively reduces the effective condenser surface area to keep your HVACR refrigeration system operating within its design parameters. This hermetically brazed unit features a pulsation damping design and stainless steel bellows to enhance service life in demanding commercial environments. With an adjustment range of 73 to 254 psig and a factory setting of 145 psig, the KVR 22 regulator provides the precise control needed to prevent liquid slugging and ensure reliable expansion valve performance. It is compatible with a wide array of refrigerants, including R22, R134a, R404A, and R507, making it a versatile choice for retrofit and new installations alike.
Key Benefits:- Optimized Head Pressure Control: Maintains consistent receiver pressure to prevent system failure during cold-weather startups.
- Refined Technical Build: Features a stainless steel bellows and a compact angle design for reliable installation in restricted spaces.
- Integrated Service Access: Includes a 1/4 inch Schrader valve access port for rapid pressure gauge connection and troubleshooting.
- High Pressure Resilience: Rated for a maximum working pressure (MWP) of 406 psig (28 bar), suitable for high-pressure refrigerants.
- How do I adjust the pressure setting on the KVR 22? Remove the protective cap and turn the adjustment spindle. Clockwise increases the opening pressure, while counter-clockwise decreases it. Always use a high-pressure gauge at the access port for precise calibration.
- Where is the ideal placement for this valve? In most air-cooled systems, the Danfoss 034L0094 is installed in the liquid line between the condenser and the receiver to regulate liquid flow based on inlet pressure.
- Is a check valve required with this installation? If the regulator is installed in a hot gas bypass application, a check valve (like the NRD) should be utilized to prevent refrigerant migration back into the cold condenser.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.