Danfoss 032F8166 Parts Kit
Field-service technicians requiring a reliable repair solution for Danfoss EVR 6 solenoid valves can utilize the 032F8166 spare parts kit to restore optimal valve performance without replacing the entire body. Designed specifically for refrigeration solenoid valve maintenance, this kit address common failure points in normally closed (NC) configurations. The kit includes a precision-engineered diaphragm assembly and necessary sealing components compatible with a wide range of fluorinated refrigerants, including R22, R134a, R404A, and R507. Maintaining a tight seal at the valve seat is critical for preventing bypass and ensuring high-side to low-side integrity. This Danfoss 032F8166 service kit is engineered for high-pressure applications, supporting a Maximum Working Pressure (MWP) of up to 45.2 bar. By replacing worn internal components with OEM Danfoss parts, contractors ensure thermal expansion efficiency and precise refrigerant flow control within the HVACR system, reducing downtime and preventing moisture ingress during the repair process.
Key Benefits for the Technician- System Integrity: Re-establishes a leak-proof seal at the solenoid diaphragm, preventing internal refrigerant migration.
- Refrigerant Compatibility: Specialized elastomers are rated for modern HFC and HCFC refrigerants and POE/PAG oils.
- Direct Fitment: Eliminates the need for pipe cutting or brazing by utilizing the existing EVR 6 valve body.
- Extended Service Life: High-grade stainless steel and reinforced polymers withstand rapid cycling in refrigeration liquid lines.
Is this kit compatible with EVR 6 version 1 and version 2?
This kit is primarily designed for the current EVR 6 series. Always verify the code number on the valve body to ensure the diaphragm diameter matches the kit specifications.
Does the kit include the solenoid coil?
No, the 032F8166 consists of internal mechanical components only. If the issue is electrical, the Danfoss 12W or 10W coil must be tested and replaced separately.
Can this be used for suction line applications?
Yes, provided the minimum pressure drop required for the diaphragm to lift is maintained according to the EVR 6 technical data sheet.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Danfoss 032F8166 Parts Kit
Field-service technicians requiring a reliable repair solution for Danfoss EVR 6 solenoid valves can utilize the 032F8166 spare parts kit to restore optimal valve performance without replacing the entire body. Designed specifically for refrigeration solenoid valve maintenance, this kit address common failure points in normally closed (NC) configurations. The kit includes a precision-engineered diaphragm assembly and necessary sealing components compatible with a wide range of fluorinated refrigerants, including R22, R134a, R404A, and R507. Maintaining a tight seal at the valve seat is critical for preventing bypass and ensuring high-side to low-side integrity. This Danfoss 032F8166 service kit is engineered for high-pressure applications, supporting a Maximum Working Pressure (MWP) of up to 45.2 bar. By replacing worn internal components with OEM Danfoss parts, contractors ensure thermal expansion efficiency and precise refrigerant flow control within the HVACR system, reducing downtime and preventing moisture ingress during the repair process.
Key Benefits for the Technician- System Integrity: Re-establishes a leak-proof seal at the solenoid diaphragm, preventing internal refrigerant migration.
- Refrigerant Compatibility: Specialized elastomers are rated for modern HFC and HCFC refrigerants and POE/PAG oils.
- Direct Fitment: Eliminates the need for pipe cutting or brazing by utilizing the existing EVR 6 valve body.
- Extended Service Life: High-grade stainless steel and reinforced polymers withstand rapid cycling in refrigeration liquid lines.
Is this kit compatible with EVR 6 version 1 and version 2?
This kit is primarily designed for the current EVR 6 series. Always verify the code number on the valve body to ensure the diaphragm diameter matches the kit specifications.
Does the kit include the solenoid coil?
No, the 032F8166 consists of internal mechanical components only. If the issue is electrical, the Danfoss 12W or 10W coil must be tested and replaced separately.
Can this be used for suction line applications?
Yes, provided the minimum pressure drop required for the diaphragm to lift is maintained according to the EVR 6 technical data sheet.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Field-service technicians requiring a reliable repair solution for Danfoss EVR 6 solenoid valves can utilize the 032F8166 spare parts kit to restore optimal valve performance without replacing the entire body. Designed specifically for refrigeration solenoid valve maintenance, this kit address common failure points in normally closed (NC) configurations. The kit includes a precision-engineered diaphragm assembly and necessary sealing components compatible with a wide range of fluorinated refrigerants, including R22, R134a, R404A, and R507. Maintaining a tight seal at the valve seat is critical for preventing bypass and ensuring high-side to low-side integrity. This Danfoss 032F8166 service kit is engineered for high-pressure applications, supporting a Maximum Working Pressure (MWP) of up to 45.2 bar. By replacing worn internal components with OEM Danfoss parts, contractors ensure thermal expansion efficiency and precise refrigerant flow control within the HVACR system, reducing downtime and preventing moisture ingress during the repair process.
Key Benefits for the Technician- System Integrity: Re-establishes a leak-proof seal at the solenoid diaphragm, preventing internal refrigerant migration.
- Refrigerant Compatibility: Specialized elastomers are rated for modern HFC and HCFC refrigerants and POE/PAG oils.
- Direct Fitment: Eliminates the need for pipe cutting or brazing by utilizing the existing EVR 6 valve body.
- Extended Service Life: High-grade stainless steel and reinforced polymers withstand rapid cycling in refrigeration liquid lines.
Is this kit compatible with EVR 6 version 1 and version 2?
This kit is primarily designed for the current EVR 6 series. Always verify the code number on the valve body to ensure the diaphragm diameter matches the kit specifications.
Does the kit include the solenoid coil?
No, the 032F8166 consists of internal mechanical components only. If the issue is electrical, the Danfoss 12W or 10W coil must be tested and replaced separately.
Can this be used for suction line applications?
Yes, provided the minimum pressure drop required for the diaphragm to lift is maintained according to the EVR 6 technical data sheet.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.