Daikin-McQuay 910143408 Room Sensor
HomeStore

Daikin-McQuay 910143408 Room Sensor

Daikin-McQuay 910143408 Room Sensor

The Daikin-McQuay 910143408 Room Sensor is a precision-engineered OEM replacement part designed for high-accuracy temperature monitoring in MicroTech III unit controllers. Built to interface seamlessly with Daikin Applied systems weight-optimized for commercial performance, this 10k thermistor sensor supports both constant volume (CAV) and variable air volume (VAV) applications. Operating on a versatile 9-40V, 10VDC, or 15-28 VAC power range, it provides a stable signal to the HVAC controller, ensuring the facility maintains optimal environmental setpoints. The unit features a high-visibility LCD display with 0.1-degree increments, integrated setpoint adjustment buttons, and a tenant override function to trigger temporary occupied modes. For professional installation, technicians should utilize 22 AWG twisted pair wiring and ensure the sensor is shielded from internal wall cavity drafts to prevent erroneous readings and premature unit failure.

Key Benefits:
  • Direct OEM Compatibility: Engineered specifically for Daikin DSP, MPS, RAH, RPS, and SWP unit models as a reliable drop-in replacement.
  • Advanced Interface: Features integrated up/down setpoint keys and a tenant override button to allow for localized zone control.
  • Industrial Durability: Constructed with UL94V-0 ABS plastic, rated for ambient operating temperatures between 32°F and 122°F.
  • Precision Monitoring: Utilizes a 10k ohm thermistor to deliver highly accurate data for building automation and energy management systems.
Common Questions:

Is this sensor compatible with non-Daikin controllers?
This HVAC room sensor is specifically designed for Daikin MicroTech III logic and standard 10k thermistor inputs. Verify your controller's resistance curve before attempting cross-brand integration.

How do I prevent ghost readings after installation?
Technicians must plug the conduit hole with insulation in the junction box. This prevents unconditioned air from within the wall cavity from affecting the digital room temperature sensor.

Can this unit be used as a standalone thermostat?
No, the 910143408 is a space sensor that communicates with a centralized unit controller. It does not contain internal relays for direct equipment switching.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$59.01

Original: $168.60

-65%
Daikin-McQuay 910143408 Room Sensor

$168.60

$59.01

Daikin-McQuay 910143408 Room Sensor

The Daikin-McQuay 910143408 Room Sensor is a precision-engineered OEM replacement part designed for high-accuracy temperature monitoring in MicroTech III unit controllers. Built to interface seamlessly with Daikin Applied systems weight-optimized for commercial performance, this 10k thermistor sensor supports both constant volume (CAV) and variable air volume (VAV) applications. Operating on a versatile 9-40V, 10VDC, or 15-28 VAC power range, it provides a stable signal to the HVAC controller, ensuring the facility maintains optimal environmental setpoints. The unit features a high-visibility LCD display with 0.1-degree increments, integrated setpoint adjustment buttons, and a tenant override function to trigger temporary occupied modes. For professional installation, technicians should utilize 22 AWG twisted pair wiring and ensure the sensor is shielded from internal wall cavity drafts to prevent erroneous readings and premature unit failure.

Key Benefits:
  • Direct OEM Compatibility: Engineered specifically for Daikin DSP, MPS, RAH, RPS, and SWP unit models as a reliable drop-in replacement.
  • Advanced Interface: Features integrated up/down setpoint keys and a tenant override button to allow for localized zone control.
  • Industrial Durability: Constructed with UL94V-0 ABS plastic, rated for ambient operating temperatures between 32°F and 122°F.
  • Precision Monitoring: Utilizes a 10k ohm thermistor to deliver highly accurate data for building automation and energy management systems.
Common Questions:

Is this sensor compatible with non-Daikin controllers?
This HVAC room sensor is specifically designed for Daikin MicroTech III logic and standard 10k thermistor inputs. Verify your controller's resistance curve before attempting cross-brand integration.

How do I prevent ghost readings after installation?
Technicians must plug the conduit hole with insulation in the junction box. This prevents unconditioned air from within the wall cavity from affecting the digital room temperature sensor.

Can this unit be used as a standalone thermostat?
No, the 910143408 is a space sensor that communicates with a centralized unit controller. It does not contain internal relays for direct equipment switching.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Daikin-McQuay 910143408 Room Sensor is a precision-engineered OEM replacement part designed for high-accuracy temperature monitoring in MicroTech III unit controllers. Built to interface seamlessly with Daikin Applied systems weight-optimized for commercial performance, this 10k thermistor sensor supports both constant volume (CAV) and variable air volume (VAV) applications. Operating on a versatile 9-40V, 10VDC, or 15-28 VAC power range, it provides a stable signal to the HVAC controller, ensuring the facility maintains optimal environmental setpoints. The unit features a high-visibility LCD display with 0.1-degree increments, integrated setpoint adjustment buttons, and a tenant override function to trigger temporary occupied modes. For professional installation, technicians should utilize 22 AWG twisted pair wiring and ensure the sensor is shielded from internal wall cavity drafts to prevent erroneous readings and premature unit failure.

Key Benefits:
  • Direct OEM Compatibility: Engineered specifically for Daikin DSP, MPS, RAH, RPS, and SWP unit models as a reliable drop-in replacement.
  • Advanced Interface: Features integrated up/down setpoint keys and a tenant override button to allow for localized zone control.
  • Industrial Durability: Constructed with UL94V-0 ABS plastic, rated for ambient operating temperatures between 32°F and 122°F.
  • Precision Monitoring: Utilizes a 10k ohm thermistor to deliver highly accurate data for building automation and energy management systems.
Common Questions:

Is this sensor compatible with non-Daikin controllers?
This HVAC room sensor is specifically designed for Daikin MicroTech III logic and standard 10k thermistor inputs. Verify your controller's resistance curve before attempting cross-brand integration.

How do I prevent ghost readings after installation?
Technicians must plug the conduit hole with insulation in the junction box. This prevents unconditioned air from within the wall cavity from affecting the digital room temperature sensor.

Can this unit be used as a standalone thermostat?
No, the 910143408 is a space sensor that communicates with a centralized unit controller. It does not contain internal relays for direct equipment switching.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.