Upgrade or repair your refrigeration systems with the Copeland 971-0127-06 Overload, a critical external motor protector engineered for high-demand compressor applications. Designed specifically for compatibility with CRA1719-138 model motor protectors and a wide range of Emerson Copeland compressors, this component acts as the primary defense against internal motor failure. With a 60A electrical rating, it precisely monitors current flow and thermal thresholds to provide overcurrent protection, instantly cutting power if line conditions exceed safe operating limits. This thermal overload relay is essential for preventing winding burnouts caused by locked rotor conditions or phase loss. Its compact, external-mount design ensures a straightforward OEM replacement process in tight housing compartments, maintaining the operational integrity of your HVACR equipment. Rely on this refrigerant motor protector to handle fluctuating current levels and safeguard against overheating in commercial and industrial settings.

Key Benefits:

  • Optimized Motor Protection: Prevents motor winding failure by responding rapidly to high current and overheating conditions.
  • Technical Compatibility: Engineered as a direct fit for Copeland compressor parts, specifically the CRA1719-138 protector series.
  • Durable 60A Rating: Built to withstand the rigorous electrical ratings required for industrial refrigeration and heavy-duty HVAC applications.
  • External Mounting: Allows for easier diagnostic access and replacement compared to internal sensing units.

Common Questions:

How do I verify if the 971-0127-06 is tripped?
Using a multimeter, technicians should check for continuity across the protector terminals. If the circuit is open while the compressor is cool, the overload relay has likely failed or reached its end of life.

Can I use this for both single-phase and three-phase Copeland units?
This external protector is specifically calibrated for certain motor profiles. Always cross-reference the rated-load current (RLC) on the compressor nameplate with the 60A threshold of this part to ensure accurate overload protection.

What causes this external overload to trigger frequently?
Frequent tripping usually indicates low voltage, a failing start capacitor, or restricted refrigerant flow causing high head pressure. Always inspect the external protector wiring for heat damage during routine service.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$25.10

Original: $71.71

-65%
Copeland 971-0127-06 Overload

$71.71

$25.10

Copeland 971-0127-06 Overload

Upgrade or repair your refrigeration systems with the Copeland 971-0127-06 Overload, a critical external motor protector engineered for high-demand compressor applications. Designed specifically for compatibility with CRA1719-138 model motor protectors and a wide range of Emerson Copeland compressors, this component acts as the primary defense against internal motor failure. With a 60A electrical rating, it precisely monitors current flow and thermal thresholds to provide overcurrent protection, instantly cutting power if line conditions exceed safe operating limits. This thermal overload relay is essential for preventing winding burnouts caused by locked rotor conditions or phase loss. Its compact, external-mount design ensures a straightforward OEM replacement process in tight housing compartments, maintaining the operational integrity of your HVACR equipment. Rely on this refrigerant motor protector to handle fluctuating current levels and safeguard against overheating in commercial and industrial settings.

Key Benefits:

  • Optimized Motor Protection: Prevents motor winding failure by responding rapidly to high current and overheating conditions.
  • Technical Compatibility: Engineered as a direct fit for Copeland compressor parts, specifically the CRA1719-138 protector series.
  • Durable 60A Rating: Built to withstand the rigorous electrical ratings required for industrial refrigeration and heavy-duty HVAC applications.
  • External Mounting: Allows for easier diagnostic access and replacement compared to internal sensing units.

Common Questions:

How do I verify if the 971-0127-06 is tripped?
Using a multimeter, technicians should check for continuity across the protector terminals. If the circuit is open while the compressor is cool, the overload relay has likely failed or reached its end of life.

Can I use this for both single-phase and three-phase Copeland units?
This external protector is specifically calibrated for certain motor profiles. Always cross-reference the rated-load current (RLC) on the compressor nameplate with the 60A threshold of this part to ensure accurate overload protection.

What causes this external overload to trigger frequently?
Frequent tripping usually indicates low voltage, a failing start capacitor, or restricted refrigerant flow causing high head pressure. Always inspect the external protector wiring for heat damage during routine service.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

Upgrade or repair your refrigeration systems with the Copeland 971-0127-06 Overload, a critical external motor protector engineered for high-demand compressor applications. Designed specifically for compatibility with CRA1719-138 model motor protectors and a wide range of Emerson Copeland compressors, this component acts as the primary defense against internal motor failure. With a 60A electrical rating, it precisely monitors current flow and thermal thresholds to provide overcurrent protection, instantly cutting power if line conditions exceed safe operating limits. This thermal overload relay is essential for preventing winding burnouts caused by locked rotor conditions or phase loss. Its compact, external-mount design ensures a straightforward OEM replacement process in tight housing compartments, maintaining the operational integrity of your HVACR equipment. Rely on this refrigerant motor protector to handle fluctuating current levels and safeguard against overheating in commercial and industrial settings.

Key Benefits:

  • Optimized Motor Protection: Prevents motor winding failure by responding rapidly to high current and overheating conditions.
  • Technical Compatibility: Engineered as a direct fit for Copeland compressor parts, specifically the CRA1719-138 protector series.
  • Durable 60A Rating: Built to withstand the rigorous electrical ratings required for industrial refrigeration and heavy-duty HVAC applications.
  • External Mounting: Allows for easier diagnostic access and replacement compared to internal sensing units.

Common Questions:

How do I verify if the 971-0127-06 is tripped?
Using a multimeter, technicians should check for continuity across the protector terminals. If the circuit is open while the compressor is cool, the overload relay has likely failed or reached its end of life.

Can I use this for both single-phase and three-phase Copeland units?
This external protector is specifically calibrated for certain motor profiles. Always cross-reference the rated-load current (RLC) on the compressor nameplate with the 60A threshold of this part to ensure accurate overload protection.

What causes this external overload to trigger frequently?
Frequent tripping usually indicates low voltage, a failing start capacitor, or restricted refrigerant flow causing high head pressure. Always inspect the external protector wiring for heat damage during routine service.