As an experienced HVACR tech, you know that a failed compressor start can lead to compounding system issues. The Copeland 914-0053-10 Start Capacitor is a high-performance, non-polarized electrolytic component engineered specifically for high-torque applications. Rated for 145-174 Microfarad (MFD) at 250Vac, this round start capacitor provides the necessary phase shift to initiate the starting torque required by single-phase compressors and motors. Unlike standard run capacitors, this motor start capacitor is designed for intermittent duty, effectively dropping out of the circuit via a potential relay once the motor reaches approximately 75% of its rated speed.

Encased in a moisture and oil-resistant phenolic resin case, the Copeland 914-0053-10 is a direct OEM replacement for older or failed 145-175 MFD units, including legacy part numbers like 914-0038-10 and 014-0053-26. With 1/4" quick disconnect terminals and a compact round form factor (approximately 1-13/16" diameter), it fits seamlessly into standard electrical housings. This HVAC compressor capacitor is UL 810 recognized and rated for frequencies of 50/60 Hz, ensuring stable performance across various Copeland compressor start kit configurations and general-purpose motor applications.

Key Benefits for Technicians:
  • Precise 145-174 MFD Range: Optimized for high-torque starting requirements to prevent motor stalling and heat buildup.
  • Industrial-Grade Housing: The rugged phenolic resin construction provides superior insulation and protection against harsh mechanical room environments.
  • Dual-Blade Terminals: Features standard 1/4" male quick-connect tabs for fast, secure wiring.
  • Broad Compatibility: Serves as a technical replacement for numerous 220-250V start capacitors in refrigeration and AC equipment.
  • Intermittent Duty Specialized: Engineered specifically for the high-amperage surge of motor startup without risking premature dielectric breakdown.
Common Questions:

Can I use this 250V capacitor to replace a 165V unit?
Yes, in capacitor physics, you can always go up in voltage rating. Using a 250Vac start capacitor to replace a lower voltage (like 165V or 220V) unit is a safe and often more durable upgrade for the circuit.

Is this capacitor polarized?
No, this is a non-polarized AC electrolytic capacitor. It is designed for use in AC motor circuits where the voltage periodically reverses.

What happens if the microfarad rating isn't exact?
The 145-174 MFD range is a standard tolerance for these HVACR replacement parts. As long as your failed unit falls within or very close to this range (e.g., 145-175 MFD), it will provide the correct starting torque.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$27.46

Original: $78.47

-65%
Copeland 914-0053-10 Start Capacitor

$78.47

$27.46

Copeland 914-0053-10 Start Capacitor

As an experienced HVACR tech, you know that a failed compressor start can lead to compounding system issues. The Copeland 914-0053-10 Start Capacitor is a high-performance, non-polarized electrolytic component engineered specifically for high-torque applications. Rated for 145-174 Microfarad (MFD) at 250Vac, this round start capacitor provides the necessary phase shift to initiate the starting torque required by single-phase compressors and motors. Unlike standard run capacitors, this motor start capacitor is designed for intermittent duty, effectively dropping out of the circuit via a potential relay once the motor reaches approximately 75% of its rated speed.

Encased in a moisture and oil-resistant phenolic resin case, the Copeland 914-0053-10 is a direct OEM replacement for older or failed 145-175 MFD units, including legacy part numbers like 914-0038-10 and 014-0053-26. With 1/4" quick disconnect terminals and a compact round form factor (approximately 1-13/16" diameter), it fits seamlessly into standard electrical housings. This HVAC compressor capacitor is UL 810 recognized and rated for frequencies of 50/60 Hz, ensuring stable performance across various Copeland compressor start kit configurations and general-purpose motor applications.

Key Benefits for Technicians:
  • Precise 145-174 MFD Range: Optimized for high-torque starting requirements to prevent motor stalling and heat buildup.
  • Industrial-Grade Housing: The rugged phenolic resin construction provides superior insulation and protection against harsh mechanical room environments.
  • Dual-Blade Terminals: Features standard 1/4" male quick-connect tabs for fast, secure wiring.
  • Broad Compatibility: Serves as a technical replacement for numerous 220-250V start capacitors in refrigeration and AC equipment.
  • Intermittent Duty Specialized: Engineered specifically for the high-amperage surge of motor startup without risking premature dielectric breakdown.
Common Questions:

Can I use this 250V capacitor to replace a 165V unit?
Yes, in capacitor physics, you can always go up in voltage rating. Using a 250Vac start capacitor to replace a lower voltage (like 165V or 220V) unit is a safe and often more durable upgrade for the circuit.

Is this capacitor polarized?
No, this is a non-polarized AC electrolytic capacitor. It is designed for use in AC motor circuits where the voltage periodically reverses.

What happens if the microfarad rating isn't exact?
The 145-174 MFD range is a standard tolerance for these HVACR replacement parts. As long as your failed unit falls within or very close to this range (e.g., 145-175 MFD), it will provide the correct starting torque.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

As an experienced HVACR tech, you know that a failed compressor start can lead to compounding system issues. The Copeland 914-0053-10 Start Capacitor is a high-performance, non-polarized electrolytic component engineered specifically for high-torque applications. Rated for 145-174 Microfarad (MFD) at 250Vac, this round start capacitor provides the necessary phase shift to initiate the starting torque required by single-phase compressors and motors. Unlike standard run capacitors, this motor start capacitor is designed for intermittent duty, effectively dropping out of the circuit via a potential relay once the motor reaches approximately 75% of its rated speed.

Encased in a moisture and oil-resistant phenolic resin case, the Copeland 914-0053-10 is a direct OEM replacement for older or failed 145-175 MFD units, including legacy part numbers like 914-0038-10 and 014-0053-26. With 1/4" quick disconnect terminals and a compact round form factor (approximately 1-13/16" diameter), it fits seamlessly into standard electrical housings. This HVAC compressor capacitor is UL 810 recognized and rated for frequencies of 50/60 Hz, ensuring stable performance across various Copeland compressor start kit configurations and general-purpose motor applications.

Key Benefits for Technicians:
  • Precise 145-174 MFD Range: Optimized for high-torque starting requirements to prevent motor stalling and heat buildup.
  • Industrial-Grade Housing: The rugged phenolic resin construction provides superior insulation and protection against harsh mechanical room environments.
  • Dual-Blade Terminals: Features standard 1/4" male quick-connect tabs for fast, secure wiring.
  • Broad Compatibility: Serves as a technical replacement for numerous 220-250V start capacitors in refrigeration and AC equipment.
  • Intermittent Duty Specialized: Engineered specifically for the high-amperage surge of motor startup without risking premature dielectric breakdown.
Common Questions:

Can I use this 250V capacitor to replace a 165V unit?
Yes, in capacitor physics, you can always go up in voltage rating. Using a 250Vac start capacitor to replace a lower voltage (like 165V or 220V) unit is a safe and often more durable upgrade for the circuit.

Is this capacitor polarized?
No, this is a non-polarized AC electrolytic capacitor. It is designed for use in AC motor circuits where the voltage periodically reverses.

What happens if the microfarad rating isn't exact?
The 145-174 MFD range is a standard tolerance for these HVACR replacement parts. As long as your failed unit falls within or very close to this range (e.g., 145-175 MFD), it will provide the correct starting torque.