The Conbraco 38-103-01 Breaker is a professional-grade 1/2 inch FNPT atmospheric vacuum breaker engineered for high-reliability back-siphonage prevention in potable water systems. Built as part of the Apollo 38-100 series, this valve features a rough brass finish and a durable bronze body construction, making it a staple for commercial and industrial plumbing applications. Designed to handle a maximum operating pressure of 125 psig and temperatures ranging from 33°F to 212°F, it is ideal for low-flow installations. The heat-resistant silicone seat disc ensures a tight seal under varying thermal conditions, while the polypropylene softgoods offer excellent chemical resistance. This backflow preventer must be installed at least 6 inches above all downstream piping to function correctly. It is specifically intended for non-continuous pressure applications where the valve is pressurized for no more than 12 hours in a 24-hour period. For technicians, the compact profile and easy-to-maintain internal components minimize downtime during routine inspections.

Key Benefits
  • Corrosion-Resistant Construction: Heavy-duty bronze body with a rough brass finish ensures longevity in demanding environments.
  • High Temperature Rating: Integrated silicone seat disc allows for reliable performance in hot or cold water service up to 212°F.
  • Code Compliance: Meets ASSE 1001 and CSA B64.1.1 standards for atmospheric type vacuum breakers.
  • Simplified Maintenance: Lightweight design and straightforward internal assembly allow for fast field repairs without removing the body from the line.
  • Back-Siphonage Protection: Effectively prevents the migration of pollutants into the potable water supply during a vacuum event.
Common Questions

Is the Conbraco 38-103-01 suitable for continuous pressure?
No, this atmospheric vacuum breaker is designed for non-continuous pressure only. It should not be under pressure for more than 12 hours in any 24-hour period to prevent the internal float from sticking.

Can I install a shut-off valve downstream of this breaker?
Standard plumbing code and manufacturer specifications dictate that there should be no shut-off valves or obstructions located downstream of an atmospheric vacuum breaker.

What is the minimum installation height for this valve?
To ensure proper atmospheric venting and prevent backflow, the unit must be installed at least 6 inches above the highest point of the downstream piping or the overflow rim of the fixture it serves.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$82.61
Conbraco 38-103-01 Breaker
$82.61

Conbraco 38-103-01 Breaker

The Conbraco 38-103-01 Breaker is a professional-grade 1/2 inch FNPT atmospheric vacuum breaker engineered for high-reliability back-siphonage prevention in potable water systems. Built as part of the Apollo 38-100 series, this valve features a rough brass finish and a durable bronze body construction, making it a staple for commercial and industrial plumbing applications. Designed to handle a maximum operating pressure of 125 psig and temperatures ranging from 33°F to 212°F, it is ideal for low-flow installations. The heat-resistant silicone seat disc ensures a tight seal under varying thermal conditions, while the polypropylene softgoods offer excellent chemical resistance. This backflow preventer must be installed at least 6 inches above all downstream piping to function correctly. It is specifically intended for non-continuous pressure applications where the valve is pressurized for no more than 12 hours in a 24-hour period. For technicians, the compact profile and easy-to-maintain internal components minimize downtime during routine inspections.

Key Benefits
  • Corrosion-Resistant Construction: Heavy-duty bronze body with a rough brass finish ensures longevity in demanding environments.
  • High Temperature Rating: Integrated silicone seat disc allows for reliable performance in hot or cold water service up to 212°F.
  • Code Compliance: Meets ASSE 1001 and CSA B64.1.1 standards for atmospheric type vacuum breakers.
  • Simplified Maintenance: Lightweight design and straightforward internal assembly allow for fast field repairs without removing the body from the line.
  • Back-Siphonage Protection: Effectively prevents the migration of pollutants into the potable water supply during a vacuum event.
Common Questions

Is the Conbraco 38-103-01 suitable for continuous pressure?
No, this atmospheric vacuum breaker is designed for non-continuous pressure only. It should not be under pressure for more than 12 hours in any 24-hour period to prevent the internal float from sticking.

Can I install a shut-off valve downstream of this breaker?
Standard plumbing code and manufacturer specifications dictate that there should be no shut-off valves or obstructions located downstream of an atmospheric vacuum breaker.

What is the minimum installation height for this valve?
To ensure proper atmospheric venting and prevent backflow, the unit must be installed at least 6 inches above the highest point of the downstream piping or the overflow rim of the fixture it serves.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Conbraco 38-103-01 Breaker is a professional-grade 1/2 inch FNPT atmospheric vacuum breaker engineered for high-reliability back-siphonage prevention in potable water systems. Built as part of the Apollo 38-100 series, this valve features a rough brass finish and a durable bronze body construction, making it a staple for commercial and industrial plumbing applications. Designed to handle a maximum operating pressure of 125 psig and temperatures ranging from 33°F to 212°F, it is ideal for low-flow installations. The heat-resistant silicone seat disc ensures a tight seal under varying thermal conditions, while the polypropylene softgoods offer excellent chemical resistance. This backflow preventer must be installed at least 6 inches above all downstream piping to function correctly. It is specifically intended for non-continuous pressure applications where the valve is pressurized for no more than 12 hours in a 24-hour period. For technicians, the compact profile and easy-to-maintain internal components minimize downtime during routine inspections.

Key Benefits
  • Corrosion-Resistant Construction: Heavy-duty bronze body with a rough brass finish ensures longevity in demanding environments.
  • High Temperature Rating: Integrated silicone seat disc allows for reliable performance in hot or cold water service up to 212°F.
  • Code Compliance: Meets ASSE 1001 and CSA B64.1.1 standards for atmospheric type vacuum breakers.
  • Simplified Maintenance: Lightweight design and straightforward internal assembly allow for fast field repairs without removing the body from the line.
  • Back-Siphonage Protection: Effectively prevents the migration of pollutants into the potable water supply during a vacuum event.
Common Questions

Is the Conbraco 38-103-01 suitable for continuous pressure?
No, this atmospheric vacuum breaker is designed for non-continuous pressure only. It should not be under pressure for more than 12 hours in any 24-hour period to prevent the internal float from sticking.

Can I install a shut-off valve downstream of this breaker?
Standard plumbing code and manufacturer specifications dictate that there should be no shut-off valves or obstructions located downstream of an atmospheric vacuum breaker.

What is the minimum installation height for this valve?
To ensure proper atmospheric venting and prevent backflow, the unit must be installed at least 6 inches above the highest point of the downstream piping or the overflow rim of the fixture it serves.