ClimateMaster 14B0058N02 Motor
The ClimateMaster 14B0058N02 is an OEM-grade tri-voltage variable speed motor engineered for high-static residential and commercial water source heat pump applications. This 3/4 HP ECM blower motor operates across a versatile range of 115/208-230/277V, making it a critical drop-in replacement for failed air handler or fan coil units. As a direct replacement for legacy part numbers 14B0037N05 and 14B0037N06, this motor provides the precise airflow control necessary to maintain system delta-T and optimize dehumidification cycles. The advanced variable speed technology allows the motor to ramp up or down based on call demand, reducing mechanical stress on the blower wheel and decreasing overall energy consumption compared to standard PSC motors. For contractors, this unit simplifies inventory by covering multiple voltage requirements with a single SKU. Ensure the control board and 16-pin connector are inspected for thermal damage prior to installation to prevent premature failure of the new module.
Key Benefits:- Tri-Voltage Compatibility: Supports 115V, 208-230V, and 277V electrical configurations for maximum site flexibility.
- OEM Precision: A genuine ClimateMaster replacement part designed to match factory CFM curves and programming.
- Enhanced Efficiency: Variable speed motor design reduces electrical load and provides quieter operation in part-load conditions.
- Broad Application: Compatible with various ClimateMaster heat pumps, air handlers, and specialized HVAC equipment.
Does this motor require programming in the field?
This 14B0058N02 motor comes with factory-loaded parameters for ClimateMaster equipment, though you must verify that the dip switch settings on the unit's control board match the specific blower table for your model.
What are the signs that my current 3/4 HP motor module has failed?
Technicians should look for a "hunting" or oscillating blower speed, a complete lack of G-call response despite 24V signal, or an internal short-to-ground. Always check the 5-pin power and 16-pin control harnesses before condemning the motor.
Can I use this to replace a 1/2 HP or 1 HP motor?
It is critical to match the horsepower (HP) and RPM specs of the original nameplate. Moving to a different power rating can cause static pressure imbalances or board communication errors.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $715.56
-65%$715.56
$250.45ClimateMaster 14B0058N02 Motor
The ClimateMaster 14B0058N02 is an OEM-grade tri-voltage variable speed motor engineered for high-static residential and commercial water source heat pump applications. This 3/4 HP ECM blower motor operates across a versatile range of 115/208-230/277V, making it a critical drop-in replacement for failed air handler or fan coil units. As a direct replacement for legacy part numbers 14B0037N05 and 14B0037N06, this motor provides the precise airflow control necessary to maintain system delta-T and optimize dehumidification cycles. The advanced variable speed technology allows the motor to ramp up or down based on call demand, reducing mechanical stress on the blower wheel and decreasing overall energy consumption compared to standard PSC motors. For contractors, this unit simplifies inventory by covering multiple voltage requirements with a single SKU. Ensure the control board and 16-pin connector are inspected for thermal damage prior to installation to prevent premature failure of the new module.
Key Benefits:- Tri-Voltage Compatibility: Supports 115V, 208-230V, and 277V electrical configurations for maximum site flexibility.
- OEM Precision: A genuine ClimateMaster replacement part designed to match factory CFM curves and programming.
- Enhanced Efficiency: Variable speed motor design reduces electrical load and provides quieter operation in part-load conditions.
- Broad Application: Compatible with various ClimateMaster heat pumps, air handlers, and specialized HVAC equipment.
Does this motor require programming in the field?
This 14B0058N02 motor comes with factory-loaded parameters for ClimateMaster equipment, though you must verify that the dip switch settings on the unit's control board match the specific blower table for your model.
What are the signs that my current 3/4 HP motor module has failed?
Technicians should look for a "hunting" or oscillating blower speed, a complete lack of G-call response despite 24V signal, or an internal short-to-ground. Always check the 5-pin power and 16-pin control harnesses before condemning the motor.
Can I use this to replace a 1/2 HP or 1 HP motor?
It is critical to match the horsepower (HP) and RPM specs of the original nameplate. Moving to a different power rating can cause static pressure imbalances or board communication errors.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The ClimateMaster 14B0058N02 is an OEM-grade tri-voltage variable speed motor engineered for high-static residential and commercial water source heat pump applications. This 3/4 HP ECM blower motor operates across a versatile range of 115/208-230/277V, making it a critical drop-in replacement for failed air handler or fan coil units. As a direct replacement for legacy part numbers 14B0037N05 and 14B0037N06, this motor provides the precise airflow control necessary to maintain system delta-T and optimize dehumidification cycles. The advanced variable speed technology allows the motor to ramp up or down based on call demand, reducing mechanical stress on the blower wheel and decreasing overall energy consumption compared to standard PSC motors. For contractors, this unit simplifies inventory by covering multiple voltage requirements with a single SKU. Ensure the control board and 16-pin connector are inspected for thermal damage prior to installation to prevent premature failure of the new module.
Key Benefits:- Tri-Voltage Compatibility: Supports 115V, 208-230V, and 277V electrical configurations for maximum site flexibility.
- OEM Precision: A genuine ClimateMaster replacement part designed to match factory CFM curves and programming.
- Enhanced Efficiency: Variable speed motor design reduces electrical load and provides quieter operation in part-load conditions.
- Broad Application: Compatible with various ClimateMaster heat pumps, air handlers, and specialized HVAC equipment.
Does this motor require programming in the field?
This 14B0058N02 motor comes with factory-loaded parameters for ClimateMaster equipment, though you must verify that the dip switch settings on the unit's control board match the specific blower table for your model.
What are the signs that my current 3/4 HP motor module has failed?
Technicians should look for a "hunting" or oscillating blower speed, a complete lack of G-call response despite 24V signal, or an internal short-to-ground. Always check the 5-pin power and 16-pin control harnesses before condemning the motor.
Can I use this to replace a 1/2 HP or 1 HP motor?
It is critical to match the horsepower (HP) and RPM specs of the original nameplate. Moving to a different power rating can cause static pressure imbalances or board communication errors.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.