The Cleveland Controls NS2-1306-01 Pressure Switch is a high-precision airflow monitoring solution designed for contractors and technicians working with modern HVAC and industrial pneumatic systems. This differential air pressure switch is factory-calibrated to a .37" W.C. actuation point, providing reliable safety interlocking for furnaces, air handlers, and boilers. Built for longevity in rigorous environments, it features a glass-filled polycarbonate housing that resists impact and contaminants, ensuring the diaphragm and snap-acting switch maintain accuracy over thousands of cycles. Whether you are performing a duct pressure switch replacement or integrating a sensor into a new ventilation build, this component offers the versatility to handle pressure, vacuum, or differential sensing. The electrical interface is streamlined for the field, utilizing three 90° male quick-connect terminals for fast, secure wiring. This NS2-1306-01 airflow switch is a critical safeguard, ensuring that combustion air and system flow meet required thresholds before operation, effectively protecting equipment and maintaining system efficiency.

Key Benefits for Technicians:

  • Enhanced Durability: The glass-filled polycarbonate housing provides superior structural integrity compared to standard plastic switches, making it ideal for high-heat HVAC environments.
  • Flexible Actuation: Engineered to monitor positive pressure, vacuum, or differential airflow, allowing one part number to serve multiple diagnostic and safety roles.
  • Reliable Calibration: Factory-set at .37 inches water column, ensuring consistent performance without the need for field adjustment in standard applications.
  • Simplified Installation: Features 90-degree quick-connect terminals that allow for easy access in tight furnace cabinets or control panels.
  • Broad Compatibility: A trusted OEM replacement pressure switch for various ventilation systems, ensuring safe operation by verifying proper fan performance.

Common Questions:

Can this switch be used for both positive and negative pressure?
Yes, the Cleveland Controls NS2-1306-01 is designed to actuate via pressure, vacuum, or the differential between two air sources, making it adaptable to several system configurations.

What are the symptoms of a failing pressure switch in a furnace?
Common indicators include the inducer motor running without the ignition sequence starting, or the system throwing a specific fault code related to "pressure switch stuck open" or "failed to close."

How do I ensure the hose connection is correct during replacement?
Always verify the port markings on the switch body; the differential ports must be connected correctly to the high and low sides of the inducer or flue to achieve the .37" W.C. trip point.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$21.29

Original: $60.82

-65%
Cleveland Controls NS2-1306-01 Pressure Switch

$60.82

$21.29

Cleveland Controls NS2-1306-01 Pressure Switch

The Cleveland Controls NS2-1306-01 Pressure Switch is a high-precision airflow monitoring solution designed for contractors and technicians working with modern HVAC and industrial pneumatic systems. This differential air pressure switch is factory-calibrated to a .37" W.C. actuation point, providing reliable safety interlocking for furnaces, air handlers, and boilers. Built for longevity in rigorous environments, it features a glass-filled polycarbonate housing that resists impact and contaminants, ensuring the diaphragm and snap-acting switch maintain accuracy over thousands of cycles. Whether you are performing a duct pressure switch replacement or integrating a sensor into a new ventilation build, this component offers the versatility to handle pressure, vacuum, or differential sensing. The electrical interface is streamlined for the field, utilizing three 90° male quick-connect terminals for fast, secure wiring. This NS2-1306-01 airflow switch is a critical safeguard, ensuring that combustion air and system flow meet required thresholds before operation, effectively protecting equipment and maintaining system efficiency.

Key Benefits for Technicians:

  • Enhanced Durability: The glass-filled polycarbonate housing provides superior structural integrity compared to standard plastic switches, making it ideal for high-heat HVAC environments.
  • Flexible Actuation: Engineered to monitor positive pressure, vacuum, or differential airflow, allowing one part number to serve multiple diagnostic and safety roles.
  • Reliable Calibration: Factory-set at .37 inches water column, ensuring consistent performance without the need for field adjustment in standard applications.
  • Simplified Installation: Features 90-degree quick-connect terminals that allow for easy access in tight furnace cabinets or control panels.
  • Broad Compatibility: A trusted OEM replacement pressure switch for various ventilation systems, ensuring safe operation by verifying proper fan performance.

Common Questions:

Can this switch be used for both positive and negative pressure?
Yes, the Cleveland Controls NS2-1306-01 is designed to actuate via pressure, vacuum, or the differential between two air sources, making it adaptable to several system configurations.

What are the symptoms of a failing pressure switch in a furnace?
Common indicators include the inducer motor running without the ignition sequence starting, or the system throwing a specific fault code related to "pressure switch stuck open" or "failed to close."

How do I ensure the hose connection is correct during replacement?
Always verify the port markings on the switch body; the differential ports must be connected correctly to the high and low sides of the inducer or flue to achieve the .37" W.C. trip point.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Cleveland Controls NS2-1306-01 Pressure Switch is a high-precision airflow monitoring solution designed for contractors and technicians working with modern HVAC and industrial pneumatic systems. This differential air pressure switch is factory-calibrated to a .37" W.C. actuation point, providing reliable safety interlocking for furnaces, air handlers, and boilers. Built for longevity in rigorous environments, it features a glass-filled polycarbonate housing that resists impact and contaminants, ensuring the diaphragm and snap-acting switch maintain accuracy over thousands of cycles. Whether you are performing a duct pressure switch replacement or integrating a sensor into a new ventilation build, this component offers the versatility to handle pressure, vacuum, or differential sensing. The electrical interface is streamlined for the field, utilizing three 90° male quick-connect terminals for fast, secure wiring. This NS2-1306-01 airflow switch is a critical safeguard, ensuring that combustion air and system flow meet required thresholds before operation, effectively protecting equipment and maintaining system efficiency.

Key Benefits for Technicians:

  • Enhanced Durability: The glass-filled polycarbonate housing provides superior structural integrity compared to standard plastic switches, making it ideal for high-heat HVAC environments.
  • Flexible Actuation: Engineered to monitor positive pressure, vacuum, or differential airflow, allowing one part number to serve multiple diagnostic and safety roles.
  • Reliable Calibration: Factory-set at .37 inches water column, ensuring consistent performance without the need for field adjustment in standard applications.
  • Simplified Installation: Features 90-degree quick-connect terminals that allow for easy access in tight furnace cabinets or control panels.
  • Broad Compatibility: A trusted OEM replacement pressure switch for various ventilation systems, ensuring safe operation by verifying proper fan performance.

Common Questions:

Can this switch be used for both positive and negative pressure?
Yes, the Cleveland Controls NS2-1306-01 is designed to actuate via pressure, vacuum, or the differential between two air sources, making it adaptable to several system configurations.

What are the symptoms of a failing pressure switch in a furnace?
Common indicators include the inducer motor running without the ignition sequence starting, or the system throwing a specific fault code related to "pressure switch stuck open" or "failed to close."

How do I ensure the hose connection is correct during replacement?
Always verify the port markings on the switch body; the differential ports must be connected correctly to the high and low sides of the inducer or flue to achieve the .37" W.C. trip point.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

You may also like

-65%NEW
Thumbnail 1

Cleveland Controls AFS-271-396 Air Flow Switch

$146.66

$51.33

-65%NEW
Thumbnail 1

Cleveland Controls NS2-0556-00 Pressure Switch

$40.33

$14.12

-65%NEW
Thumbnail 1

Cleveland Controls NS2-1333-02 Pressure Switch

$60.82

$21.29

-65%NEW
Thumbnail 1

Cleveland Controls NS2-0111-00 Pressure Switch

$46.93

$16.43

NEW
Thumbnail 1

Cleveland Controls NS2-0548-00 Pressure Switch

$60.82

-65%NEW
Thumbnail 1

Cleveland Controls NS2-1052-00 Pressure Switch

$60.82

$21.29

-65%NEW
Thumbnail 1

Cleveland Controls NS2-1306-02 Pressure Switch

$56.22

$19.68

-65%NEW
Thumbnail 1

Cleveland Controls DDP-106-112 Sensing Switch

$105.87

$37.05

NEW
Thumbnail 1

Cleveland Controls RFS-4001-110 Pressure Switch

$54.72

-65%NEW
Thumbnail 1

Cleveland Controls DDP-106-223 Air Flow Switch

$130.13

$45.55

-65%NEW
Thumbnail 1

Cleveland Controls DDP-106-313 Sensing Switch

$338.93

$118.63